Pipeline Embolization Device and Pipeline Flex Versus Surpass Streamline Flow Diversion in Intracranial Aneurysms: A Retrospective Propensity Score-Matched Study

被引:13
作者
Feigen, Chaim M. [1 ]
Vivanco-Suarez, Juan [2 ]
Javed, Kainaat [1 ]
Dardick, Joseph M. [1 ]
Holland, Ryan [1 ]
Mendez-Ruiz, Alan [2 ]
Ortega-Gutierrez, Santiago [2 ]
Haranhalli, Neil [1 ]
Altschul, David J. [1 ]
机构
[1] Montefiore Dept Neurol Surg, Bronx, NY 10467 USA
[2] Univ Iowa Hosp & Clin, Dept Neurol Neurosurg & Radiol, Iowa City, IA 52242 USA
关键词
Aneurysm; Flow diversion; Pipeline embolization; Stent; Stroke; Subarachnoid hemorrhage; CAROTID-ARTERY ANEURYSMS; DIVERTOR; TECHNOLOGY; EXPERIENCE; OUTCOMES; HISTORY;
D O I
10.1016/j.wneu.2022.02.025
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To compare safety and efficacy profiles in aneurysms treated with Pipeline Embolization Device or Pipeline Flex versus Surpass Streamline flow diverters (FDs). METHODS: Patients who underwent flow diversion for aneurysm treatment at 2 centers were included. Covariates comprised patient demographics, comorbidities, and aneurysm characteristics. Metrics included number of devices, adjuvant device use, case duration, and radiation exposure. Outcomes included periprocedural complications and radiographic results at follow-up. Propensity score-matched pairs were generated using demographic and aneurysm characteristics to verify the outcomes in equally sized groups. RESULTS: The majority of 141 flow diversion procedures performed on 126 patients were in the anterior circulation (96%) and unruptured (93%). Operators experienced more complications placing Surpass FDs compared with Pipelines (18.2% vs. 3.1%, P = 0.005) but used fewer Surpass devices per case (1 device in all Surpass cases and range for Pipeline cases 1-7; P < 0.001). Ballooning was more frequent for Surpass (29.5% vs. 2.1%, P < 0.001). There were no differences in mortality (2.1% vs. 0, P = 1.00), intracranial hemorrhage (3.1% vs. 0, P = 0.551), or stroke (4.2% vs. 6.8%, P = 0.680). Rates of aneurysm obliteration at follow-up were similar. Propensity-matched pairs had no differences in FD deployment complications or perioperative events, yet the significant differences remained for adjuvant balloon use and number of FDs deployed. CONCLUSIONS: While the devices demonstrated similar safety and efficacy profiles, deployment of the Surpass Streamline was more technically challenging than Pipeline Embolization Device or Pipeline Flex. Prospective cohort studies are needed to corroborate these findings.
引用
收藏
页码:E384 / E394
页数:11
相关论文
共 31 条
[1]  
[Anonymous], 2019, MATLAB 960 R2019A
[2]   Long-Term Clinical and Angiographic Outcomes Following Pipeline Embolization Device Treatment of Complex Internal Carotid Artery Aneurysms: Five-Year Results of the Pipeline for Uncoilable or Failed Aneurysms Trial [J].
Becske, Tibor ;
Brinjikji, Waleed ;
Potts, Matthew B. ;
Kallmes, David F. ;
Shapiro, Maksim ;
Moran, Christopher J. ;
Levy, Elad I. ;
McDougall, Cameron G. ;
Szikora, Istvan ;
Lanzino, Giuseppe ;
Woo, Henry H. ;
Lopes, Demetrius K. ;
Siddiqui, Adnan H. ;
Albuquerque, Felipe C. ;
Fiorella, David J. ;
Saatci, Isil ;
Cekirge, Saruhan H. ;
Berez, Aaron L. ;
Cher, Daniel J. ;
Berentei, Zsolt ;
Marosfoi, Miklos ;
Nelson, Peter K. .
NEUROSURGERY, 2017, 80 (01) :40-48
[3]   Endovascular treatment of cerebral aneurysms using flow-diverter devices: A systematic review [J].
Briganti, Francesco ;
Leone, Giuseppe ;
Marseglia, Mariano ;
Mariniello, Giuseppe ;
Caranci, Ferdinando ;
Brunetti, Arturo ;
Maiuri, Francesco .
NEURORADIOLOGY JOURNAL, 2015, 28 (04) :365-375
[4]   Flow diversion of large internal carotid artery aneurysms with the surpass device: impressions and technical nuance from the initial North American experience [J].
Colby, Geoffrey P. ;
Lin, Li-Mei ;
Caplan, Justin M. ;
Jiang, Bowen ;
Michniewicz, Barbara ;
Huang, Judy ;
Tamargo, Rafael J. ;
Coon, Alexander L. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (03) :279-286
[5]   Review of current intracranial aneurysm flow diversion technology and clinical use [J].
Dandapat, Sudeepta ;
Mendez-Ruiz, Alan ;
Martinez-Galdamez, Mario ;
Macho, Juan ;
Derakhshani, Shahram ;
Foa Torres, Gustavo ;
Pereira, Vitor M. ;
Arat, Anil ;
Wakhloo, Ajay K. ;
Ortega-Gutierrez, Santiago .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2021, 13 (01) :54-+
[6]   New Generation of Flow Diverter (Surpass) for Unruptured Intracranial Aneurysms A Prospective Single-Center Study in 37 Patients [J].
De Vries, Joost ;
Boogaarts, Jeroen ;
Van Norden, Anouk ;
Wakhloo, Ajay K. .
STROKE, 2013, 44 (06) :1567-1577
[7]  
Diedrich Karl T, 2011, AMIA Annu Symp Proc, V2011, P295
[8]   In-vitro thrombogenicity assessment of flow diversion and aneurysm bridging devices [J].
Girdhar, Gaurav ;
Li, Junwei ;
Kostousov, Larisa ;
Wainwright, John ;
Chandler, Wayne L. .
JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2015, 40 (04) :437-443
[9]   Prospective study on embolization of intracranial aneurysms with the pipeline device: the PREMIER study 1 year results [J].
Hanel, Ricardo A. ;
Kallmes, David F. ;
Lopes, Demetrius Klee ;
Nelson, Peter Kim ;
Siddiqui, Adnan ;
Jabbour, Pascal ;
Pereira, Vitor M. ;
Istvan, Istvan Szikora ;
Zaidat, Osama O. ;
Bettegowda, Chetan ;
Colby, Geoffrey P. ;
Mokin, Maxim ;
Schirmer, Clemens ;
Hellinger, Frank R. ;
Given, Curtis, II ;
Krings, Timo ;
Taussky, Philipp ;
Toth, Gabor ;
Fraser, Justin F. ;
Chen, Michael ;
Priest, Ryan ;
Kan, Peter ;
Fiorella, David ;
Frei, Don ;
Aagaard-Kienitz, Beverly ;
Diaz, Orlando ;
Malek, Adel M. ;
Cawley, C. Michael ;
Puri, Ajit S. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (01) :62-66
[10]   Histopathological assessment of fatal ipsilateral intraparenchymal hemorrhages after the treatment of supraclinoid aneurysms with the Pipeline Embolization Device [J].
Hu, Yin C. ;
Deshmukh, Vivek R. ;
Albuquerque, Felipe C. ;
Fiorella, David ;
Nixon, Randal R. ;
Heck, Donald V. ;
Barnwell, Stanley L. ;
McDougall, Cameron G. .
JOURNAL OF NEUROSURGERY, 2014, 120 (02) :365-374