Intra and interobserver reliability of angular kinematic analysis of the hip joint during the sit-and-reach test to measure hamstring length in university students

被引:13
|
作者
Cardoso, J. R. [1 ]
Azevedo, N. C. T.
Cassano, C. S.
Kawano, M. M. [1 ]
Ambar, G.
机构
[1] Univ Estadual Londrina, Ctr Ciencias Saude, Dept Fisioterapia, Londrina, PR, Brazil
关键词
biomechanics; hip joint; physical examination; test reproducibility;
D O I
10.1590/S1413-35552007000200008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The sit-and-reach test (SRT) is used to measure the flexibility of the lumbar spine and hamstring muscles and is better when the hip joint angle (HJA) is measured concomitantly. Objective: To assess the intra and interobserver reliability of the SRT for measuring hamstring muscle length through angular kinematic analysis. Method: Fifty university students (X = 21.5 years; SD = 1.5) without musculoskeletal abnormalities took part. A standard SRT bench with a door (to assess the action of the gastrocnemius muscles) and a digital photographic camera positioned oil a tripod were used. Skin markers were placed oil the anterosuperior iliac spine and greater trochanter. Two images were recorded: one with the door closed (DC) and another with the door open (DO). To test the intra and interobserver reliability, the intraclass correlation coefficient (ICC) (random effect with one factor) and the Bland and Altman concordance test ((d) over bar = mean difference between measurements) were used, with the respective 95% confidence intervals (95% CI). Results: The intraobserver reliability of the HJA test was: ICCdc = 0.97 (95% CI [0.95;0.99]) and Bland and Altman (d) over bar = -0.02 (95% CI [-0.11;0.071); ICCdo = 0.98 (95% CI [0.96;0.991), (d) over bar = -0.01 (95% CI [-0.11;0.08]). For the interobserver reliability: ICCdc= 0.96 (95% CI [0.94;0.98]) and (d) over bar = -0.07 (95% CI [-0.19;0.03]); ICCdo = 0.96 (95% CI [0.93;0.98] and (d) over bar = -0.06 (95% CI [-0.19;0.52]. Conclusion: The intra and interobserver reliability tests (DC and DO) for HJA assessment using kinematic analysis showed high reliability. The technique is easy to apply (only requiring a standard SRT bench and a photographic camera) and provides a reliable method for measuring hamstring muscles using kinematic analysis in clinical practice.
引用
收藏
页码:133 / 138
页数:6
相关论文
共 6 条
  • [1] Validity of hamstring muscle length assessment during the sit-and-reach test using an inclinometer to measure hip joint angle
    Youdas, James W.
    Krause, David A.
    Hollman, John H.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2008, 22 (01) : 303 - 309
  • [2] Reliability and validity of a chair sit-and-reach test to measure hamstring flexibility in older adults
    Jones, J
    Rikli, R
    Noffal, G
    JOURNAL OF AGING AND PHYSICAL ACTIVITY, 1997, 5 (04) : 375 - 375
  • [3] Assessment of hamstring muscle length in school-aged children using the sit-and-reach test and the inclinometer measure of hip joint angle
    Cornbleet, SL
    Woolsey, NB
    PHYSICAL THERAPY, 1996, 76 (08): : 850 - 855
  • [4] The reliability and validity of a chair sit-and-reach test as a measure of hamstring flexibility in older adults
    Jones, CJ
    Rikli, RE
    Max, J
    Noffal, G
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 1998, 69 (04) : 338 - 343
  • [5] Influence of the gastrocnemius muscle on the sit-and-reach test assessed by angular kinematic analysis
    Kawano, Marcio M.
    Ambar, Gabriel
    Oliveira, Beatriz I. R.
    Boer, Marcela C.
    Cardoso, Ana P. R. G.
    Cardoso, Jefferson R.
    BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2010, 14 (01) : 10 - 15
  • [6] Video Analysis Of Spine And Hip Angles During The Sit-and-Reach Test
    Mier, Constance
    Shapiro, Belinda
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 80 - 80