Frameless robotically targeted stereotactic brain biopsy: feasibility, diagnostic yield, and safety

被引:68
作者
Bekelis, Kimon [1 ]
Badwan, Tarek A. [1 ]
Desai, Atman [1 ]
Roberts, David W. [1 ,2 ,3 ]
机构
[1] Dartmouth Hitchcock Med Ctr, Neurosurg Sect, Hanover, NH USA
[2] Dartmouth Hitchcock Med Ctr, Dept Neurol, Hanover, NH USA
[3] Dartmouth Coll, Hitchcock Med Ctr, Dartmouth Med Sch, Hanover, NH 03756 USA
关键词
robotics; stereotaxy; frameless brain biopsy; tumor; neuronavigation; diagnostic and operative techniques; oncology; MOUNTED INSTRUMENT HOLDER; ELECTRODE IMPLANTATION; TECHNICAL NOTE; ROBOT; ACCURACY; SURGERY; NEUROSURGERY; SYSTEM; VENTRICULOSTOMY; COMPLICATIONS;
D O I
10.3171/2012.1.JNS111746
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Frameless stereotactic brain biopsy has become an established procedure in many neurosurgical centers worldwide. Robotic modifications of image-guided frameless stereotaxy hold promise for making these procedures safer, more effective, and more efficient. The authors hypothesized that robotic brain biopsy is a safe, accurate procedure, with a high diagnostic yield and a safety profile comparable to other stereotactic biopsy methods. Methods. This retrospective study included 41 patients undergoing frameless stereotactic brain biopsy of lesions (mean size 2.9 cm) for diagnostic purposes. All patients underwent image-guided, robotic biopsy in which the SurgiScope system was used in conjunction with scalp fiducial markers and a preoperatively selected target and trajectory. Forty-five procedures, with 50 supratentorial targets selected, were performed. Results. The mean operative time was 44.6 minutes for the robotic biopsy procedures. This decreased over the second half of the study by 37%, from 54.7 to 34.5 minutes (p < 0.025). The diagnostic yield was 97.8% per procedure, with a second procedure being diagnostic in the single nondiagnostic case. Complications included one transient worsening of a preexisting deficit (2%) and another deficit that was permanent (2%). There were no infections. Conclusions. Robotic biopsy involving a preselected target and trajectory is safe, accurate, efficient, and comparable to other procedures employing either frame-based stereotaxy or frameless, nonrobotic stereotaxy. It permits biopsy in all patients, including those with small target lesions. Robotic biopsy planning facilitates careful preoperative study and optimization of needle trajectory to avoid sulcal vessels, bridging veins, and ventricular penetration. (http://thejns.org/doi/abs/10.3171/2012.1.JNS111746)
引用
收藏
页码:1002 / 1006
页数:5
相关论文
共 44 条
  • [1] BACKLUND EO, 1971, ACTA CHIR SCAND, V137, P825
  • [2] Frameless stereotaxy with scalp-applied fiducial markers for brain biopsy procedures: experience in 218 cases
    Barnett, GH
    Miller, DW
    Weisenberger, J
    [J]. JOURNAL OF NEUROSURGERY, 1999, 91 (04) : 569 - 576
  • [3] Benabid A L, 1992, Acta Neurochir Suppl (Wien), V54, P93
  • [4] Benabid A L, 1991, Adv Tech Stand Neurosurg, V18, P3
  • [5] BENABID AL, 1987, APPL NEUROPHYSIOL, V50, P153
  • [6] Histological yield, complications, and technological considerations in 114 consecutive frameless stereotactic biopsy procedures aided by open intraoperative magnetic resonance imaging
    Bernays, RL
    Kollias, SS
    Khan, N
    Brandner, S
    Meier, S
    Yonekawa, Y
    [J]. JOURNAL OF NEUROSURGERY, 2002, 97 (02) : 354 - 362
  • [7] Comparison of accuracy and precision between frame-based and frameless stereotactic navigation for deep brain stimulation electrode implantation
    Bjartmarz, Hjalmar
    Rehncrona, Stig
    [J]. STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2007, 85 (05) : 235 - 242
  • [8] ROBOTS IN OPERATING-THEATERS
    BUCKINGHAM, RA
    BUCKINGHAM, RO
    [J]. BRITISH MEDICAL JOURNAL, 1995, 311 (7018) : 1479 - 1482
  • [9] An analysis of the accuracy of the Cyberknife: A robotic nameless stereotactic radiosurgical system
    Chang, SD
    Main, W
    Martin, DP
    Gibbs, IC
    Heilbrun, MP
    [J]. NEUROSURGERY, 2003, 52 (01) : 140 - 146
  • [10] Safety and efficacy of frameless and frame-based intracranial biopsy techniques
    Dammers, R.
    Haitsma, I. K.
    Schouten, J. W.
    Kros, J. M.
    Avezaat, C. J. J.
    Vincent, A. J. P. E.
    [J]. ACTA NEUROCHIRURGICA, 2008, 150 (01) : 23 - 29