Renewable amperometric immunosensor for complement 3 (C3) assay in human serum

被引:27
作者
Liu, GD [1 ]
Yan, JT [1 ]
Shen, GL [1 ]
Yu, RQ [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, Inst Chemometr & Sensing Technol, Changsha 410082, Peoples R China
基金
中国国家自然科学基金;
关键词
renewable; immunosensor; amperometric; complement; 3; paraffin;
D O I
10.1016/S0925-4005(01)00880-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A renewable electrochemical immunosensor has been developed for the determination of complement 3 (C-3) in human serum. It is based on a paraffin-graphite-complement 3 antiserum biocomposite, which needs no additional curing. The analytical sample containing sought for C-3 was mixed with C-3 labeled with horseradish peroxidase (HRP) to form the incubation solution. A competitive binding assay was realized by dipping the biocomposite immunosensor into the incubation mixture. After rinsing away the excess of HRP-C-3, the amount of HP,P fixed on the sensor surface was determined amperometrically, the current signal was inversely proportional to the amount of sought-for C-3 in the incubation mixture. Assay conditions were optimized including the loading of C-3 antiserum in the biocomposite, the amount of labeled C-3 in incubation solution, incubation time and temperature. Using o-aminophenol (o-AP) as a substrate, amperometric detection at - 150 mV (versus SCE) results in a linear range of 1.17-29.25 mug/ml. Serum samples were analyzed and the results demonstrated that the concentration in this system meets the demands of clinical analysis. The surface of the immunosensor can be regenerated by simply polishing to obtain a fresh immunocomposite ready to be used in a new competitive assay. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:95 / 100
页数:6
相关论文
共 20 条
[1]   New variants of enzyme immunoassay of antibodies to DNA [J].
Babkina, SS ;
Medyantseva, EP ;
Budnikov, HC ;
Tyshiek, MP .
ANALYTICAL CHEMISTRY, 1996, 68 (21) :3827-3831
[2]  
González-Martínez MA, 1999, ANAL CHIM ACTA, V386, P201, DOI 10.1016/S0003-2670(99)00032-X
[3]  
Hage DS, 1999, ANAL CHEM, V71, p294R
[4]   Differential pulse voltammetric enzyme-linked immunoassay for the determination of Helicobacter pylori specific immunoglobulin G (IgG) antibody [J].
He, YN ;
Chen, HY ;
Zheng, JJ ;
Zhang, GY ;
Chen, ZL .
TALANTA, 1997, 44 (05) :823-830
[5]   STRATEGIES FOR ELECTROCHEMICAL IMMUNOASSAY [J].
HEINEMAN, WR ;
HALSALL, HB .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :1321-&
[6]   Disposable liposome immunosensor for theophylline combining an immunochromatographic membrane and a thick-film electrode [J].
Lee, KS ;
Kim, TH ;
Shin, MC ;
Lee, WY ;
Park, JK .
ANALYTICA CHIMICA ACTA, 1999, 380 (01) :17-26
[7]   Automated detection of anti-double-stranded DNA antibody in systemic lupus erythematosus serum by flow immunoassay [J].
Lim, T ;
Komoda, Y ;
Nakamura, N ;
Matsunaga, T .
ANALYTICAL CHEMISTRY, 1999, 71 (07) :1298-1302
[8]  
LIU YH, 1991, IMMUNOLOGY IMMUNODIA, P182
[9]  
MAUNAERT E, 1994, ANALYST, V119, P2221
[10]   Amperometric immunosensors and enzyme electrodes for environmental applications [J].
Parellada, J ;
Narváez, A ;
López, MA ;
Domínguez, E ;
Fernández, JJ ;
Pavlov, V ;
Katakis, I .