Joint Multi-Shot Multi-Channel Image Reconstruction in Compressive Diffusion Weighted MR Imaging

被引:0
作者
Zhang, Hao [1 ]
Chen, Yunmei [1 ]
Pasiliao, Eduardo, Jr. [2 ]
Huang, Feng [3 ]
机构
[1] Univ Florida, Dept Math, Gainesville, FL 32611 USA
[2] Air Force Res Lab, Munit Directorate, Air Force Base, OH USA
[3] Philips Healthcare Suzhou Co Ltd, Suzhou, Peoples R China
来源
MEDICAL IMAGING 2015: IMAGE PROCESSING | 2015年 / 9413卷
关键词
Image Reconstruction; MRI; multi-shot EPI; DWI; THRESHOLDING ALGORITHM; SENSE; RESOLUTION; EPI; ARTIFACTS; PERFUSION; DTI;
D O I
10.1117/12.2082104
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Single-Shot Echo-Planar-Imaging (SS-EPI) is the most common method to acquire Diffusion-Weighted-Imaging (DWI) data in clinic due to its immunity to patient motion. However, its image quality is impacted by geometric distortions and poor spatial resolution. While Multi-Shot EPI (MS-EPI) has the potential to achieve high spatial resolution, it suffers from significant motion-induced artifacts. Partially Parallel Imaging (PPI) reconstruction techniques such as Sensitivity-Encoding (SENSE) has shown its ability to improve the image quality of MRI. In this paper we proposed a SENSE based model to reconstruct DW images from MS-EPI data by solving a minimization problem. Under the condition when the motion is not significant large, We assume the images reconstructed from different shots are low rank except for sparse errors and our model is solved by an accelerated Alternating direction method of multipliers (AADMM) scheme.
引用
收藏
页数:15
相关论文
共 28 条
  • [1] Diffusion-weighted imaging with navigated interleaved echo-planar imaging and a conventional gradient system
    Bammer, P
    Stollberger, R
    Augustin, M
    Simbrunner, J
    Offenbacher, H
    Kooijman, H
    Ropele, S
    Kapeller, P
    Wach, P
    Ebner, F
    Fazekas, F
    [J]. RADIOLOGY, 1999, 211 (03) : 799 - 806
  • [2] Diffusion tensor imaging using single-shot SENSE-EPI
    Bammer, R
    Auer, M
    Keeling, SL
    Augustin, M
    Stables, LA
    Prokesch, RW
    Stollberger, R
    Moseley, ME
    Fazekas, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) : 128 - 136
  • [3] Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE)
    Bammer, R
    Keeling, SL
    Augustin, M
    Pruessmann, KP
    Wolf, R
    Stollberger, R
    Hartung, HP
    Fazekas, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 548 - 554
  • [4] A Fast Iterative Shrinkage-Thresholding Algorithm for Linear Inverse Problems
    Beck, Amir
    Teboulle, Marc
    [J]. SIAM JOURNAL ON IMAGING SCIENCES, 2009, 2 (01): : 183 - 202
  • [5] Blaimer Martin, 2004, Top Magn Reson Imaging, V15, P223, DOI 10.1097/01.rmr.0000136558.09801.dd
  • [6] Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint
    Block, Kai Tobias
    Uecker, Martin
    Frahm, Jens
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (06) : 1086 - 1098
  • [7] Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes
    Butts, K
    deCrespigny, A
    Pauly, JM
    Moseley, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) : 763 - 770
  • [8] INTERLEAVED ECHO-PLANAR IMAGING ON A STANDARD MRI SYSTEM
    BUTTS, K
    RIEDERER, SJ
    EHMAN, RL
    THOMPSON, RM
    JACK, CR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) : 67 - 72
  • [9] A SINGULAR VALUE THRESHOLDING ALGORITHM FOR MATRIX COMPLETION
    Cai, Jian-Feng
    Candes, Emmanuel J.
    Shen, Zuowei
    [J]. SIAM JOURNAL ON OPTIMIZATION, 2010, 20 (04) : 1956 - 1982
  • [10] Cercignani M, 2003, AM J NEURORADIOL, V24, P1254