Aorta and runoff vessels: Single-injection MR angiography with automated table movement compared with multiinjection time-resolved MR angiography - Initial results

被引:60
作者
Hany, TF
Carroll, TJ
Omary, RA
Eparza-Coss, E
Korosec, FR
Mistretta, CA
Grist, TM
机构
[1] Univ Wisconsin, Clin Sci Ctr E3 311, Dept Med Phys, Madison, WI 53792 USA
[2] Univ Wisconsin, Clin Sci Ctr E3 311, Dept Radiol, Madison, WI 53792 USA
[3] Ctr Invest & Estudios Avanzados, Dept Phys, Mexico City, DF, Mexico
[4] CINVESTAV, Mexico City 14000, DF, Mexico
[5] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
关键词
aorta; MR; arteries; extremities; magnetic resonance (MR); vascular studies;
D O I
10.1148/radiol.2211010119
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors compared two techniques for performing runoff, contrast material-enhanced magnetic resonance (MR) angiography. Multiinjection time-resolved imaging of contrast kinetics (TRICKS) and sing le-injection bolus-chase MR angiographic examinations were performed in 10 volunteers and 10 patients. Image quality and venous overlay of the major blood vessels of the abdomen, thigh, and calf were evaluated. Significantly more (P < .05) vessels were depicted with diagnostic quality on multiinjection TRICKS than on single-injection bolus-chase MR angiographic images.
引用
收藏
页码:266 / 272
页数:7
相关论文
共 24 条
  • [1] Carroll TJ, 2000, MAGN RESON MED, V44, P817, DOI 10.1002/1522-2594(200011)44:5<817::AID-MRM22>3.0.CO
  • [2] 2-X
  • [3] Hepatic arterial-phase dynamic gadolinium-enhanced MR imaging: Optimization with a test examination and a power injector
    Earls, JP
    Rofsky, NM
    DeCorato, DR
    Krinsky, GA
    Weinreb, JC
    [J]. RADIOLOGY, 1997, 202 (01) : 268 - 273
  • [4] Peripheral vascular tree stenoses: Evaluation with moving-bed infusion-tracking MR angiography
    Ho, KYJAM
    Leiner, T
    de Haan, MW
    Kessels, AGH
    Kitslaar, PJEHM
    van Engelshoven, JMA
    [J]. RADIOLOGY, 1998, 206 (03) : 683 - 692
  • [5] Optimization of gadolinium-enhanced magnetic resonance angiography using an automated bolus-detection algorithm (MR SmartPrep) - Original investigation
    Ho, VB
    Foo, TKF
    [J]. INVESTIGATIVE RADIOLOGY, 1998, 33 (09) : 515 - 523
  • [6] Ho VB, 1999, JMRI-J MAGN RESON IM, V10, P376, DOI 10.1002/(SICI)1522-2586(199909)10:3<376::AID-JMRI20>3.0.CO
  • [7] 2-U
  • [8] ADVERSE REACTIONS TO IONIC AND NONIONIC CONTRAST-MEDIA - A REPORT FROM THE JAPANESE-COMMITTEE-ON-THE-SAFETY-OF-CONTRAST MEDIA
    KATAYAMA, H
    YAMAGUCHI, K
    KOZUKA, T
    TAKASHIMA, T
    SEEZ, P
    MATSUURA, K
    [J]. RADIOLOGY, 1990, 175 (03) : 621 - 628
  • [9] Time-resolved contrast-enhanced 3D MR angiography
    Korosec, FR
    Frayne, R
    Grist, TM
    Mistretta, CA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) : 345 - 351
  • [10] Value of image subtraction in 3D gadolinium-enhanced MR angiography of the renal arteries
    Leung, DA
    Pelkonen, P
    Hany, TF
    Zimmermann, G
    Pfammatter, T
    Debatin, JF
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03): : 598 - 602