Performance evaluation of a gamma-ray imaging system for nondestructive testing of welded pipes

被引:7
作者
Cho, H. S. [1 ]
Oh, J. E. [1 ]
Choi, S. I. [1 ]
Cho, H. M. [1 ]
Park, Y. O. [1 ]
Hong, D. K. [1 ]
Lee, M. S. [1 ]
Yang, Y. J. [1 ]
Je, U. K. [1 ]
Kim, D. S. [1 ]
Woo, T. H. [2 ]
Lee, B. S. [3 ]
Lee, H. K. [4 ]
机构
[1] Yonsei Univ, Dept Radiol Sci, Coll Hlth Sci, Wonju 220710, South Korea
[2] Korea Res & Simulat Corp, Dept Adv Technol, Seoul 136780, South Korea
[3] Konkuk Univ, Sch Biomed Engn, Coll Biomed & Hlth Sci, Chungju 380701, South Korea
[4] Missouri Univ Sci & Technol, Dept Min & Nucl Engn, Rolla, MO 65401 USA
关键词
Gamma-ray imaging system; Nondestructive testing; Welded pipes; Image quality;
D O I
10.1016/j.nima.2010.08.045
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
As a continuation of our radiographic testing (RT) R&D, we have developed a gamma-ray imaging system to be suitable for nondestructive testing of welded pipes. The system consists of an imaging detector having a CdTe/CMOS-based pixel array (AJAT. SCAN1000), a collimated Se-75 gamma source having about 78.7 Ci activities, a gear track mounted around test pipes for image scan, and a computer-controlled microstep motor for precise control of the scan speed. All the components of the imaging system were assembled tightly by a chain belt. From the imaging system, we obtained useful gamma images of a stainless steel pipe (30 cm in internal diameter and 1 cm in thickness) having a weld line. Using standard techniques for evaluation of the radiography quality, we assessed the imaging characteristics of the detector in terms of the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE). Crown Copyright (C) 2010 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:650 / 653
页数:4
相关论文
共 9 条
[1]  
[Anonymous], SCAN 1000
[2]   Application of artificial neural network to discrimination of defect type in automatic radiographic testing of welds [J].
Aoki, K ;
Suga, Y .
ISIJ INTERNATIONAL, 1999, 39 (10) :1081-1087
[3]   Performance of a Digital Gamma-Imaging System Based Upon CdTe-CMOS Sensor and 75 Se Source for Nondestructive Testing [J].
Cho, H. S. ;
Lee, S. Y. ;
Choi, S. I. ;
Oh, J. E. ;
Cho, H. M. ;
Kim, K. Y. ;
Lee, B. S. ;
Kim, S. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (05) :2716-2720
[4]   Pattern recognition of weld defects detected by radiographic test [J].
da Silva, RR ;
Calôba, LP ;
Siqueira, MHS ;
Rebello, JMA .
NDT & E INTERNATIONAL, 2004, 37 (06) :461-470
[5]   A SIMPLE METHOD FOR DETERMINING THE MODULATION TRANSFER-FUNCTION IN DIGITAL RADIOGRAPHY [J].
FUJITA, H ;
TSAI, DY ;
ITOH, T ;
DOI, K ;
MORISHITA, J ;
UEDA, K ;
OHTSUKA, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (01) :34-39
[6]  
GAYER A, 1990, NDT INT, V23, P131, DOI 10.1016/0963-8695(90)90628-V
[7]  
[M.D.S. Nordion GammaMat S.E.], 2006, CANADA USERS MANUAL
[8]   Image quality in two phosphor-based flat panel digital radiographic detectors [J].
Samei, E .
MEDICAL PHYSICS, 2003, 30 (07) :1747-1757
[9]   An experimental comparison of detector performance for direct and indirect digital radiography systems [J].
Samei, E ;
Flynn, MJ .
MEDICAL PHYSICS, 2003, 30 (04) :608-622