A Graphene Oxide-Based Fluorescent Method for the Detection of Human Chorionic Gonadotropin

被引:22
作者
Xia, Ning [1 ]
Wang, Xin [2 ]
Liu, Lin [1 ,2 ]
机构
[1] Anyang Normal Univ, Coll Chem & Chem Engn, Anyang 455000, Peoples R China
[2] Anyang Normal Univ, Coll Chem & Chem Engn, Henan Prov Key Lab New Optoelect Funct Mat, Anyang 455000, Peoples R China
基金
中国国家自然科学基金;
关键词
graphene oxide; fluorescent biosensors; peptide aptamer; human chorionic gonadotropin; antibody-free; ELECTROCHEMICAL IMMUNOSENSOR; IONIC LIQUID; PEPTIDE; PROTEIN; DNA; NANOPARTICLES; CELLS; GOLD; NANOCOMPOSITE; IMMUNOASSAY;
D O I
10.3390/s16101699
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Human chorionic gonadotropin (hCG) has been regarded as a biomarker for the diagnosis of pregnancy and some cancers. Because the currently used methods (e.g., disposable Point of Care Testing (POCT) device) for hCG detection require the use of many less stable antibodies, simple and cost-effective methods for the sensitive and selective detection of hCG have always been desired. In this work, we have developed a graphene oxide (GO)-based fluorescent platform for the detection of hCG using a fluorescein isothiocyanate (FITC)-labeled hCG-specific binding peptide aptamer (denoted as FITC-PPLRINRHILTR) as the probe, which can be manufactured cheaply and consistently. Specifically, FITC-PPLRINRHILTR adsorbed onto the surface of GO via electrostatic interaction showed a poor fluorescence signal. The specific binding of hCG to FITC-PPLRINRHILTR resulted in the release of the peptide from the GO surface. As a result, an enhanced fluorescence signal was observed. The fluorescence intensity was directly proportional to the hCG concentration in the range of 0.05-20 IU/mL. The detection limit was found to be 20 mIU/mL. The amenability of the strategy to hCG analysis in biological fluids was demonstrated by assaying hCG in the urine samples.
引用
收藏
页数:10
相关论文
共 52 条
  • [1] Facile colorimetric detection of human chorionic gonadotropin based on the peptide-induced aggregation of gold nanoparticles
    Chang, Chia-Chen
    Chen, Chen-Yu
    Chen, Chie-Pein
    Lin, Chii-Wann
    [J]. ANALYTICAL METHODS, 2015, 7 (01) : 29 - 33
  • [2] Colorimetric detection of human chorionic gonadotropin using catalytic gold nanoparticles and a peptide aptamer
    Chang, Chia-Chen
    Chen, Chie-Pein
    Lee, Chung-Han
    Chen, Chen-Yu
    Lin, Chii-Wann
    [J]. CHEMICAL COMMUNICATIONS, 2014, 50 (92) : 14443 - 14446
  • [3] Sweet carbon nanostructures: carbohydrate conjugates with carbon nanotubes and graphene and their applications
    Chen, Yanan
    Star, Alexander
    Vidal, Sebastien
    [J]. CHEMICAL SOCIETY REVIEWS, 2013, 42 (11) : 4532 - 4542
  • [4] An indirect perfluorosulfonated ionomer-coated electrochemical immunosensor for the detection of the protein human chorionic gonadotrophin
    Chetcuti, AF
    Wong, DKY
    Stuart, MC
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (18) : 4088 - 4094
  • [5] Fluorescence-based immunoassay for human chorionic gonadotropin based on polyfluorene-coated silica nanoparticles and polyaniline-coated Fe3O4 nanoparticles
    Chu, Chengchao
    Li, Long
    Li, Shuai
    Li, Meng
    Ge, Shenguang
    Yu, Jinghua
    Yan, Mei
    Song, Xianrang
    [J]. MICROCHIMICA ACTA, 2013, 180 (15-16) : 1509 - 1516
  • [6] Biomedical Applications of Graphene and Graphene Oxide
    Chung, Chul
    Kim, Young-Kwan
    Shin, Dolly
    Ryoo, Soo-Ryoon
    Hong, Byung Hee
    Min, Dal-Hee
    [J]. ACCOUNTS OF CHEMICAL RESEARCH, 2013, 46 (10) : 2211 - 2224
  • [7] An artificial cell-cycle inhibitor isolated from a combinatorial Library
    Cohen, BA
    Colas, P
    Brent, R
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (24) : 14272 - 14277
  • [8] Peptide aptamers in label-free protein detection: 1. Characterization of the immobilized scaffold
    Davis, Jason J.
    Tkac, Jan
    Laurenson, Sophie
    Ferrigno, Paul Ko
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (03) : 1089 - 1096
  • [9] Biosensing with Forster Resonance Energy Transfer Coupling between Fluorophores and Nanocarbon Allotropes
    Ding, Shaowei
    Cargill, Allison A.
    Das, Suprem R.
    Medintz, Igor L.
    Claussen, Jonathan C.
    [J]. SENSORS, 2015, 15 (06) : 14766 - 14787
  • [10] Antibody-free Detection of Human Chorionic Gonadotropin by Use of Liquid Crystals
    Ding, Xiaokang
    Yang, Kun-Lin
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (22) : 10710 - 10716