Fully Automated Optical Hematocrit Measurement from Dried Blood Spots

被引:17
|
作者
Luginbuhl, Marc [1 ]
Fischer, Yannick [2 ]
Gaugler, Stefan [1 ]
机构
[1] CAMAG DBS Lab, Sonnenmattstr 11, CH-4132 Muttenz, Switzerland
[2] Univ Appl Sci & Arts Northwestern Switzerland, Inst Chem & Bioanalyt, Hofackerstr 30, CH-4132 Muttenz, Switzerland
关键词
DBS SAMPLES; PREDICTION; BIAS;
D O I
10.1093/jat/bkaa189
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The impact of the hematocrit (HCT) on the dried blood spot (DBS)'s spreading area is one of the most important hurdles, which prevents the full acceptance of quantitative microsampling strategies. Several destructive and non-destructive strategies to assess the HCT from a DBS post-sampling have been presented. Unfortunately, the current methods are either labor-intensive, require a complicated algorithm or are not automatable. Here, we present a novel setup that permits the fully automated reflectance analysis to measure the HCT from a DBS. The underlying principle is based on the concept of the non-destructive single-wavelength HCT measurement. The novel module was embedded within the DBS-MS 500 platform to enable high-throughput analysis of HCT values in combination with automated DBS extraction. The novel setup was assessed and optimized for the probe to card distance, stability, anti-coagulant, spotting volume, scan number, calibration variability, accuracy and precision. It showed excellent inter-day (<= 3.7%) and intra-day (<= 1.16%) precision as well as high accuracy when analyzing authentic samples (101% +/- 7% [range: 87-127%]). Besides, the simple and straightforward application of an HCT correction for DBS was demonstrated during a pharmacokinetic study with diclofenac involving three subjects. Thereby, the sample's HCT and the HCT impact on the analyte were assessed and compensated. In conclusion, the novel setup enables quantitative analysis of non-volumetric samples in an automated fashion without compromising the concept of cost-effective, minimally invasive sampling.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 50 条
  • [1] Addressing New Possibilities and New Challenges: Automated Nondestructive Hematocrit Normalization for Dried Blood Spots
    Luginbuhl, Marc
    Gaugler, Stefan
    THERAPEUTIC DRUG MONITORING, 2021, 43 (03) : 346 - 350
  • [2] Prediction of the Hematocrit of Dried Blood Spots via Potassium Measurement on a Routine Clinical Chemistry Analyzer
    Capiau, S.
    Stove, V. V.
    Lambert, W. E.
    Stove, C. P.
    THERAPEUTIC DRUG MONITORING, 2013, 35 (05) : 659 - 659
  • [3] On the Use of Image Analysis for Hematocrit Evaluation in Dried Blood Spots
    Daousani, Chrysa
    Kostic, Nada
    Malenovic, Andelija
    Rmandic, Milena
    Dotsikas, Yannis
    APPLIED SCIENCES-BASEL, 2024, 14 (21):
  • [4] Prediction of the Hematocrit of Dried Blood Spots via Potassium Measurement on a Routine Clinical Chemistry Analyzer
    Capiau, Sara
    Stove, Veronique V.
    Lambert, Willy E.
    Stove, Christophe P.
    ANALYTICAL CHEMISTRY, 2013, 85 (01) : 404 - 410
  • [5] MEASUREMENT OF GONADOTROPINS IN DRIED BLOOD SPOTS
    WORTHMAN, CM
    STALLINGS, JF
    CLINICAL CHEMISTRY, 1994, 40 (03) : 448 - 453
  • [6] Hematocrit, blood volume, and surface area of dried blood spots - a quantitative model
    Alsous, Mervat M.
    Hawwa, Ahmed F.
    McElnay, James C.
    DRUG TESTING AND ANALYSIS, 2020, 12 (04) : 555 - 560
  • [7] Development and Validation of Hematocrit Level Measurement in Dried Blood Spots Using Near-Infrared Spectroscopy
    van de Velde, Daan
    van der Graaf, Jordy L.
    Boussaidi, Mariam
    Huisman, Ruud
    Hesselink, Dennis A.
    Russcher, Henk
    Kooij-Egas, Annelies C.
    van Maarseveen, Erik
    de Winter, Brenda C. M.
    THERAPEUTIC DRUG MONITORING, 2021, 43 (03) : 351 - 357
  • [8] Measurement of Hematocrit in Dried Blood Spots Using Near-Infrared Spectroscopy: Robust, Fast, and Nondestructive
    Oostendorp, Marlies
    El Amrani, Mohsin
    Diemel, Eric C.
    Hekman, Dennis
    van Maarseveen, Erik M.
    CLINICAL CHEMISTRY, 2016, 62 (11) : 1534 - 1536
  • [9] Fully automated correction for the hematocrit bias of non-volumetric dried blood spot phosphatidylethanol analysis
    Luginbuhl, Marc
    Stoth, Frederike
    Weinmann, Wolfgang
    Gaugler, Stefan
    ALCOHOL, 2021, 94 : 17 - 23
  • [10] FULLY AUTOMATED CORRECTION FOR THE HEMATOCRIT BIAS OF NON-VOLUMETRIC DRIED BLOOD SPOT PHOSPHATIDYLETHANOL ANALYSIS
    Luginbuhl, M.
    Stoth, F.
    Weinmann, W.
    Gaugler, S.
    ALCOHOLISM-CLINICAL AND EXPERIMENTAL RESEARCH, 2021, 45 : 85A - 86A