Evaluation of the PAR Mitigation System in Swiss PWR Containment Using the GOTHIC Code

被引:9
作者
Papini, Davide [1 ]
Andreani, Michele [1 ]
Steiner, Pascal [2 ]
Niceno, Bojan [1 ,3 ]
Klugel, Jens-Uwe [2 ]
Prasser, Horst-Michael [1 ,3 ]
机构
[1] PSI, Nucl Energy & Safety Res Dept, CH-5232 Villigen, Switzerland
[2] Kernkraftwerk Gosgen Daniken AG KKG, Safety Dept, Kraftwerkstr, CH-4658 Daniken, Switzerland
[3] Swiss Fed Inst Technol, Swiss Fed Inst Technol, Lab Nucl Energy Syst, Sonneggstr 3, CH-8092 Zurich, Switzerland
关键词
Hydrogen mitigation; fast release; severe accident; plant analysis; Thermal-hydraulics; Hydrogen; Aerosols and Iodine facility; RECOMBINER;
D O I
10.1080/00295450.2018.1505356
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The installation of passive autocatalytic recombiners (PARs) in the containment of operating nuclear power plants (NPPs) is increasingly based on three-dimensional studies of severe accidents that accurately predict the hydrogen pathways and local accumulation regions in containment and examine the mitigation effects of the PARs on the hydrogen risk. The GOTHIC (Generation Of Thermal-Hydraulic Information for Containments) code is applied in this paper to study the effectiveness of the PARs installed in the Gosgen NPP in Switzerland. A fast release of a mixture of hydrogen and steam from the hot leg during a total station blackout is chosen as the limiting scenario. The PAR modeling approach is qualified simulating two experiments performed in the frame of the OECD/NEA (Organisation for Economic Co-operation and Development/Nuclear Energy Agency) THAI (Thermal-hydraulics, Hydrogen, Aerosols and Iodine) project. The results of the plant analyses show that the recombiners cannot prevent the formation of a stratified cloud of hydrogen (10% molar concentration), but they can mitigate the hydrogen accumulation once formed. In the case of the analyzed fast release scenario, which is characterized by increasing loads with large initial flow rate and high hydrogen concentration values, it is shown that, when a large number of recombiners are installed, the global outcome in relation to the combustion risk does not depend on the details of the single PAR behavior. The hydrogen ignition risk can be fully mitigated in a timeframe ranging from 15 to 30 min after the fast release, according to the dependence of the PAR efficiency model on the adopted parameters.
引用
收藏
页码:153 / 173
页数:21
相关论文
共 30 条
[1]  
ANDREANI M., 2015, P 16 INT TOPL M NUCL
[2]  
Andreani M, 2014, PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 2B
[3]   Simulation of gas mixing and transport in a multi-compartment geometry using the GOTHIC containment code and relatively coarse meshes [J].
Andreani, Michele ;
Paladino, Domenico .
NUCLEAR ENGINEERING AND DESIGN, 2010, 240 (06) :1506-1527
[4]  
[Anonymous], 2010, NEACSNIR20103 OECD
[5]  
[Anonymous], 2014, GOTHIC THERM HYDR AN
[6]   Generic approach for designing and implementing a passive autocatalytic recombiner PAR-system in nuclear power plant containments [J].
Bachellerie, F ;
Arnould, F ;
Auglaire, M ;
de Boeck, B ;
Braillard, O ;
Eckardt, B ;
Ferroni, R ;
Moffett, R .
NUCLEAR ENGINEERING AND DESIGN, 2003, 221 (1-3) :151-165
[7]   Development of a PWR-W GOTHIC 3D model for containment accident analysis [J].
Bocanegra, Rafael ;
Jimenez, Gonzalo ;
Kevin Fernandez-Cosials, Mikel .
ANNALS OF NUCLEAR ENERGY, 2016, 87 :547-560
[8]  
D. PAPINI, 2015, P 16 INT TOPL M NUCL
[9]   Computational validation of the EPR™ combustible gas control system [J].
Dimmelmeier, Harald ;
Eyink, Juergen ;
Movahed, Mohammad-Ali .
NUCLEAR ENGINEERING AND DESIGN, 2012, 249 :118-124
[10]  
Grgic D, 2014, 23RD INTERNATIONAL CONFERENCE NUCLEAR ENERGY FOR NEW EUROPE, (NENE 2014)