In line NIR quantification of film thickness on pharmaceutical pellets during a fluid bed coating process

被引:93
作者
Lee, Min-Jeong [2 ]
Seo, Da-Young [2 ]
Lee, Hea-Eun [1 ]
Wang, In-Chun [1 ]
Kim, Woo-Sik [3 ]
Jeong, Myung-Yung [4 ]
Choi, Guang J. [1 ,2 ]
机构
[1] Inje Univ, Dept Pharmaceut Engn, Gimhae 621749, Gyeongnam, South Korea
[2] Inje Univ, Dept Smart Foods & Drugs, Gimhae 621749, Gyeongnam, South Korea
[3] Kyung Hee Univ, ILRI, Dept Chem Engn, Yongin 446701, Gyeonggi, South Korea
[4] Pusan Natl Univ, WCU Dept Cogno Mechatron Engn, Pusan 609735, South Korea
关键词
Fluid-bed coating; Coating thickness; PAT; NIR; Pellets; CLSM; NA; LASER-SCANNING MICROSCOPY; QUALITY; TABLETS; SPECTROSCOPY; SURFACE;
D O I
10.1016/j.ijpharm.2010.10.022
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Along with the risk-based approach, process analytical technology (PAT) has emerged as one of the key elements to fully implement QbD (quality-by-design). Near-infrared (NIR) spectroscopy has been extensively applied as an in-line/on-line analytical tool in biomedical and chemical industries. In this study, the film thickness on pharmaceutical pellets was examined for quantification using in-line NIR spectroscopy during a fluid-bed coating process. A precise monitoring of coating thickness and its prediction with a suitable control strategy is crucial to the quality assurance of solid dosage forms including dissolution characteristics. Pellets of a test formulation were manufactured and coated in a fluid-bed by spraying a hydroxypropyl methylcellulose (HPMC) coating solution. NIR spectra were acquired via a fiber-optic probe during the coating process, followed by multivariate analysis utilizing partial least squares (PLS) calibration models. The actual coating thickness of pellets was measured by two separate methods, confocal laser scanning microscopy (CLSM) and laser diffraction particle size analysis (LD-PSA). Both characterization methods gave superb correlation results, and all determination coefficient (R-2) values exceeded 0.995. In addition, a prediction coating experiment for 70 min demonstrated that the end-point can be accurately designated via NIR in-line monitoring with appropriate calibration models. In conclusion, our approach combining in-line NIR monitoring with CLSM and LD-PSA can be applied as an effective PAT tool for fluid-bed pellet coating processes. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:66 / 72
页数:7
相关论文
共 28 条
[1]   Quantitative analysis of film coating in a fluidized bed process by in line NIR spectrometry and multivariate batch calibration [J].
Andersson, M ;
Folestad, S ;
Gottfries, J ;
Johansson, MO ;
Josefson, M ;
Wahlund, KG .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :2099-2108
[2]   Monitoring of a film coating process for tablets using near infrared reflectance spectrometry [J].
Andersson, M ;
Josefson, M ;
Langkilde, FW ;
Wahlund, KG .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (1-2) :27-37
[3]   Analysis of film coating thickness and surface area of pharmaceutical pellets using fluorescence microscopy and image analysis [J].
Andersson, M ;
Holmquist, B ;
Lindquist, J ;
Nilsson, O ;
Wahlund, KG .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (02) :325-339
[4]  
[Anonymous], 2004, Food and Drug Administration Guidance for industry PATa framework for innovative pharmaceutical development, manufacturing and quality Assurance
[5]  
Cogdill R.P., 2007, J. Pharm. Innov, V2, P29
[6]   Quantification of microparticle coating quality by confocal laser scanning microscopy (CLSM) [J].
Depypere, F. ;
Van Oostveldt, P. ;
Pieters, J. G. ;
Dewettinck, K. .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2009, 73 (01) :179-186
[7]  
El Hagrasy A., 2006, Journal of Pharmaceutical Innovation, V1, P37, DOI [10.1007/BF02784879, DOI 10.1007/BF02784879]
[8]   Nondestructive analysis of tablet coating thicknesses usign terahertz pulsed imaging [J].
Fitzgerald, AJ ;
Cole, BE ;
Taday, PF .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2005, 94 (01) :177-183
[9]   Analysis of sustained-release tablet film coats using terahertz pulsed imaging [J].
Ho, L. ;
Mueller, R. ;
Romer, M. ;
Gordon, K. C. ;
Heinamaki, J. ;
Kleinebudde, P. ;
Pepper, M. ;
Rades, T. ;
Shen, Y. C. ;
Strachan, C. J. ;
Taday, P. F. ;
Zeitler, J. A. .
JOURNAL OF CONTROLLED RELEASE, 2007, 119 (03) :253-261
[10]   Applications of terahertz pulsed imaging to sustained-release tablet film coating quality assessment and dissolution performance [J].
Ho, Louise ;
Mueller, Ronny ;
Gordon, Keith C. ;
Kleinebudde, Peter ;
Pepper, Michael ;
Rades, Thomas ;
Shen, Yaochun ;
Taday, Philip F. ;
Zeitler, J. Axel .
JOURNAL OF CONTROLLED RELEASE, 2008, 127 (01) :79-87