Sleep state instabilities in major depressive disorder: Detection and quantification with electrocardiogram-based cardiopulmonary coupling analysis

被引:38
|
作者
Yang, Albert C. [1 ,2 ,3 ]
Yang, Cheng-Hung [2 ,4 ]
Hong, Chen-Jee [2 ,4 ]
Tsai, Shih-Jen [2 ,4 ]
Kuo, Chung-Hsun [4 ]
Peng, Chung-Kang [5 ,6 ,7 ]
Mietus, Joseph E. [5 ,6 ,7 ]
Goldberger, Ary L. [5 ,6 ,7 ]
Thomas, Robert J. [8 ]
机构
[1] Chu Tung Vet Hosp, Dept Psychiat, Chu Tung Township 31064, Hsin Chu County, Taiwan
[2] Natl Yang Ming Univ, Sch Med, Div Psychiat, Taipei 112, Taiwan
[3] Natl Yang Ming Univ, Inst Clin Med, Taipei 112, Taiwan
[4] Taipei Vet Gen Hosp, Dept Psychiat, Taipei, Taiwan
[5] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Margret & HA Rey Inst Nonlinear Dynam Med, Boston, MA USA
[6] Harvard Univ, Sch Med, Div Interdisciplinary Med & Biotechnol, Boston, MA USA
[7] Harvard Univ, Wyss Inst Biologically Inspired Engn, Boston, MA 02115 USA
[8] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Div Pulm Crit Care & Sleep, Boston, MA USA
关键词
Depression; Insomnia; Sleep stability; Cyclic alternating pattern; Cardiopulmonary coupling analysis; Electrocardiogram-derived sleep spectrogram; CYCLIC ALTERNATING PATTERN; HEART-RATE-VARIABILITY; NON-REM SLEEP; SITUATIONAL INSOMNIA; QUALITY; EEG; CAP; PARAMETERS; TRIAZOLAM; PROFILES;
D O I
10.1111/j.1469-8986.2010.01060.x
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
Sleep disruption is an important aspect of major depressive disorder but lacks an objective and inexpensive means of assessment. We evaluated the utility of electrocardiogram (ECG)-based cardiopulmonary coupling analysis to quantify physiologic sleep stability in patients with major depression. Relative to controls, unmedicated depressed patients had a reduction in high-frequency coupling, an index of stable sleep, an increase in low-frequency coupling, an index of unstable sleep, and an increase in very-low-frequency coupling, an index of wakefulness/REM sleep. The medicated depressed group showed a restoration of stable sleep to a level comparable with that of the control group. ECG-based cardiopulmonary coupling analysis may provide a simple, cost-efficient point-of-care method to quantify sleep quality/stability and to objectively evaluate the severity of insomnia in patients with major depression.
引用
收藏
页码:285 / 291
页数:7
相关论文
共 50 条
  • [1] SLEEP FRAGMENTATION IN MAJOR DEPRESSION: DETECTION AND QUANTIFICATION WITH AN ELECTROCARDIOGRAM-BASED SPECTROGRAM METHOD
    Yang, A.
    Peng, C.
    Thomas, R. J.
    SLEEP, 2012, 35 : A325 - A325
  • [2] An electrocardiogram-based technique to assess cardiopulmonary coupling during sleep
    Thomas, RJ
    Mietus, JE
    Peng, CK
    Goldberger, AL
    SLEEP, 2005, 28 (09) : 1151 - 1161
  • [3] Heritability of Abnormalities in Cardiopulmonary Coupling in Sleep Apnea: Use of an Electrocardiogram-based Technique
    Ibrahim, Lamia H.
    Jacono, Frank J.
    Patel, Sanjay R.
    Thomas, Robert J.
    Larkin, Emma K.
    Mietus, Joseph E.
    Peng, Chung-Kang
    Goldberger, Ary L.
    Redline, Susan
    SLEEP, 2010, 33 (05) : 643 - 646
  • [4] VALIDATION OF A PORTABLE MONITORING FOR THE DIAGNOSIS OF OBSTRUCTIVE SLEEP APNEA: ELECTROCARDIOGRAM-BASED CARDIOPULMONARY COUPLING
    Lu, Mi
    Fang, Fang
    Wei, Yongxiang
    SLEEP, 2019, 42
  • [5] Sleep Quality Change After Upper Airway Surgery in Obstructive Sleep Apnea: Electrocardiogram-Based Cardiopulmonary Coupling Analysis
    Choi, Ji Ho
    Thomas, Robert J.
    Suh, Soo Yeon
    Park, Il Ho
    Kim, Tae Hoon
    Lee, Sang Hag
    Lee, Heung Man
    Yun, Chang-Ho
    Lee, Seung Hoon
    LARYNGOSCOPE, 2015, 125 (07): : 1737 - 1742
  • [6] Validation of a portable monitoring device for the diagnosis of obstructive sleep apnea: electrocardiogram-based cardiopulmonary coupling
    Lu, Mi
    Fang, Fang
    Sanderson, John E.
    Ma, Chenyao
    Wang, Qianqian
    Zhan, Xiaojun
    Xie, Fei
    Xiao, Lei
    Liu, Hu
    Liu, Hongyan
    Wei, Yongxiang
    SLEEP AND BREATHING, 2019, 23 (04) : 1371 - 1378
  • [7] Validation of a portable monitoring device for the diagnosis of obstructive sleep apnea: electrocardiogram-based cardiopulmonary coupling
    Mi Lu
    Fang Fang
    John E. Sanderson
    Chenyao Ma
    Qianqian Wang
    Xiaojun Zhan
    Fei Xie
    Lei Xiao
    Hu Liu
    Hongyan Liu
    Yongxiang Wei
    Sleep and Breathing, 2019, 23 : 1371 - 1378
  • [8] AN ELECTROCARDIOGRAM-BASED TECHNIQUE TO ASSESS CARDIOPULMONARY COUPLING DURING SLEEP IN PEDIATRIC PATIENTS SUSPECTED WITH SLEEP DISORDERED BREATHING
    Schramm, P.
    Baker, D. N.
    Neville, A. G.
    Madison, S.
    Rose, M.
    Thomas, R. J.
    SLEEP, 2009, 32 : A82 - A82
  • [9] Electrocardiogram-based sleep analysis for sleep apnea screening and diagnosis
    Yan Ma
    Shuchen Sun
    Ming Zhang
    Dan Guo
    Arron Runzhou Liu
    Yulin Wei
    Chung-Kang Peng
    Sleep and Breathing, 2020, 24 : 231 - 240
  • [10] Electrocardiogram-based sleep analysis for sleep apnea screening and diagnosis
    Ma, Yan
    Sun, Shuchen
    Zhang, Ming
    Guo, Dan
    Liu, Arron Runzhou
    Wei, Yulin
    Peng, Chung-Kang
    SLEEP AND BREATHING, 2020, 24 (01) : 231 - 240