Device-handling study of a novel breath-actuated inhaler, Synchrobreathe®, versus a pMDI

被引:12
作者
Balamurugan, Santhalingam [1 ]
Apte, Komalkirti [2 ]
Singh, Bhanu Pratap [3 ]
Deb, Ashish Kumar [4 ]
Deshmukh, Chandrahas [5 ]
Modi, Kinjal [6 ]
Godse, Ajay [7 ]
Dhar, Raja [8 ]
Lahiri, Keya Rani [9 ]
Singh, Virendra [10 ]
Pandya, Hiren [11 ]
Rajan, Sujeet [12 ]
Vaidya, Abhijit [13 ]
Gaur, Vaibhav [13 ]
Gogtay, Jaideep [13 ]
机构
[1] Sri Muthukumaran Med Coll Hosp & Res Inst, Chennai, Tamil Nadu, India
[2] Chest Res Fdn, Pune, Maharashtra, India
[3] Midland Hosp, Lucknow, Uttar Pradesh, India
[4] Sudbhawana Hosp, Varanasi, Uttar Pradesh, India
[5] KEM Hosp & SGS Med Coll, Mumbai, Maharashtra, India
[6] Meeti Lifeline Hosp, Mumbai, Maharashtra, India
[7] Bhaktivedanta Hosp, Mumbai, Maharashtra, India
[8] Fortis Hosp, Kolkata, India
[9] Hosp & Res Ctr, Padmashree Dr DY Patil Med Coll, Navi Mumbai, India
[10] Asthma Bhawan, Jaipur, Rajasthan, India
[11] Ratandeep Multispecialty Hosp, Ahmadabad, Gujarat, India
[12] Bhatia Gen Hosp, Mumbai, Maharashtra, India
[13] Cipla Ltd, Med Affairs Dept, Mumbai, Maharashtra, India
关键词
Synchrobreathe; Breathactuated inhalers; BAIs; Asthma; COPD; pMDI; METERED-DOSE INHALERS; PATIENT PREFERENCE; ASTHMA; COPD; FLOW; NONADHERENCE; SATISFACTION; THERAPY; CHOICE;
D O I
10.1016/j.rmed.2019.05.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Synchrobreathe (R), a new-generation, novel breath-actuated inhaler (BAI) can address the key issues arising during the use of both pressurised metered dose inhalers ([pMDIs]; hand-breath coordination) and dry powder inhalers ([DPIs]; high inspiratory flow required) with respect to optimal drug deposition. Materials and methods: This was an open-label, prospective, 2-week, multicentre study that assessed device handling, ease of use, errors and participant perception regarding the use of Synchrobreathe (R) versus a pMDI in patients with chronic obstructive pulmonary disease (COPD) (n = 162) or asthma (n = 239) and inhaler-naive healthy volunteers (n = 59). Ability to use the device without errors at the first attempt, total number of errors before and after training, time taken to use the device correctly and total number of training sessions, and number of attempts to perform the correct technique on Day 1 and Day 14 were evaluated. Device handling and preference questionnaires were also administered on Day 14. Results: Of 460 participants, 421 completed the study. The number of participants using Synchrobreathe without any error after reading the patient information leaflet (PIL) was significantly low (p < 0.05) on Day 1. On Day 14, significantly more number of participants used Synchrobreathe without any error (p < 0.001). The total number of errors before and after training with Synchrobreathe was significantly less (p < 0.001). The average time required to perform the inhalation technique correctly (p < 0.01) and the total number of attempts (P < 0.001) with Synchrobreathe were significantly lower. The average number of attempts to inhale correctly was significantly (p < 0.001) less with Synchrobreathe on Day1 and Day 14. Most participants rated Synchrobreathe as their choice of inhaler. Conclusion: Synchrobreathe is an easy-to-use and easy-to-handle device with significantly less number of errors, which may have positive implications for disease control in asthma and COPD.
引用
收藏
页数:9
相关论文
共 38 条
[21]   Influence of particle size and patient dosing technique on lung deposition of HFA-beclomethasone from a metered dose inhaler [J].
Leach, CL ;
Davidson, PJ ;
Hasselquist, BE ;
Boudreau, RJ .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2005, 18 (04) :379-385
[22]   Results of a programme to improve house staff use of metered dose inhalers and spacers [J].
Lee-Wong, M ;
Mayo, PH .
POSTGRADUATE MEDICAL JOURNAL, 2003, 79 (930) :221-225
[23]   Inappropriate inhaler use: assessment of use and patient preference of seven inhalation devices [J].
Lenney, J ;
Innes, JA ;
Crompton, GK .
RESPIRATORY MEDICINE, 2000, 94 (05) :496-500
[24]   Asthma patients' inability to use a pressurised metered-dose inhaler (pMDI) correctly correlates with poor asthma control as defined by the Global Initiative for Asthma (GINA) strategy: a retrospective analysis [J].
Levy, Mark L. ;
Hardwell, Alison ;
McKnight, Eddie ;
Holmes, John .
PRIMARY CARE RESPIRATORY JOURNAL, 2013, 22 (04) :406-411
[25]  
LIARD R, 1995, REV EPIDEMIOL SANTE, V43, P242
[26]   Inhaler mishandling is very common in patients with chronic airflow obstruction and long-term home nebuliser use [J].
Melani, Andrea S. ;
Canessa, PierAldo ;
Coloretti, Isotta ;
DeAngelis, Giuseppe ;
DeTullio, Renato ;
Del Donno, Mario ;
Giacobbe, Raffaela ;
Scarlato, Ines ;
Serafini, Antonella ;
Barbato, Natalino ;
Vaghi, Adriano ;
Sestini, Piersante .
RESPIRATORY MEDICINE, 2012, 106 (05) :668-676
[27]   Inhaler mishandling remains common in real life and is associated with reduced disease control [J].
Melani, Andrea S. ;
Bonavia, Marco ;
Cilenti, Vincenzo ;
Cinti, Cristina ;
Lodi, Marco ;
Martucci, Paola ;
Serra, Maria ;
Scichilone, Nicola ;
Sestini, Piersante ;
Aliani, Maria ;
Neri, Margherita .
RESPIRATORY MEDICINE, 2011, 105 (06) :930-938
[28]  
Melani Andrea S, 2007, Acta Biomed, V78, P233
[29]  
Mirici A., 2001, Respirator. Diseas., V12, P13
[30]   IMPROVEMENT OF DRUG DELIVERY WITH A BREATH ACTUATED PRESSURIZED AEROSOL FOR PATIENTS WITH POOR INHALER TECHNIQUE [J].
NEWMAN, SP ;
WEISZ, AWB ;
TALAEE, N ;
CLARKE, SW .
THORAX, 1991, 46 (10) :712-716