Reduction of the negative influence of patient motion on quality of CBCT scan

被引:27
作者
Hanzelka, Tomas [1 ,2 ]
Foltan, Rene [1 ,2 ]
Horka, Edita [2 ,3 ]
Sedy, Jiri [2 ,3 ,4 ]
机构
[1] Charles Univ Prague, Fac Med 1, Dept Oral & Maxillofacial Surg, Prague 12000 2, Czech Republic
[2] Gen Univ Hosp, Prague 12000 2, Czech Republic
[3] Charles Univ Prague, Fac Med 1, Inst Dent Res, Prague 12000 2, Czech Republic
[4] Acad Sci Czech Republic, Inst Expt Med, Prague, Czech Republic
关键词
BEAM; TOMOGRAPHY;
D O I
10.1016/j.mehy.2010.07.046
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The role of cone beam computed tomography (CBCT) in imaging of the oral and maxillofacial region is well known and its indications and possibilities are still increasing. More sophisticated technologies are being developed each year, mainly providing higher resolution, bigger field of view, faster scanning and better scatter reduction. One of the major problems remaining to be solved is the unwanted movement of the patient during the scanning procedure. All hardware solutions that have been developed to fix the patient's head in a steady position have their limits. For example, they cannot eliminate small movements caused by breathing, heartbeat, and swallowing. We have developed a simple method to improve these CBCT images. The movement of the scanned object is monitored with marks attached to it. These marks are identified on every 2D image captured during the scanning procedure and used to unify the position of these 2D images. The final 3D reconstruction produces a sharper 3D data set with higher resolution and reduced blur. In conclusion, this simple method has the potential to improve the quality of CBCT scans. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:610 / 612
页数:3
相关论文
共 5 条
[1]   Development of a compact computed tomographic apparatus for dental use [J].
Arai, Y ;
Tammisalo, E ;
Iwai, K ;
Hashimoto, K ;
Shinoda, K .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) :245-248
[2]   Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: A systematic review of the literature [J].
De Vos, W. ;
Casselman, J. ;
Swennen, G. R. J. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 38 (06) :609-625
[3]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[4]   A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results [J].
Mozzo, P ;
Procacci, C ;
Tacconi, A ;
Martini, PT ;
Andreis, IAB .
EUROPEAN RADIOLOGY, 1998, 8 (09) :1558-1564
[5]  
Scarfe WC, 2006, J CAN DENT ASSOC, V72, P75