RF signals provide additional information on embolic events recorded during TCD monitoring

被引:15
作者
Cowe, J
Gittins, J
Naylor, AR
Evans, DH
机构
[1] Univ Leicester, Dept Cardiovasc Sci, Leicester, Leics, England
[2] Univ Hosp Leicester, Dept Med Phys, Leicester, Leics, England
关键词
RF signal; embolus detection; TCD; gold standard;
D O I
10.1016/j.ultrasmedbio.2005.02.002
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Transcranial Doppler ultrasound (TCD) is commonly used to detect embolic signals in the cerebral circulation. However, current techniques to discriminate between signals from emboli and artifacts are subjective and ambiguous. The radiofrequency (RF) signal provides an extra dimension to the information available from conventional TCD systems that may help to interpret complex events. Artifacts generated by healthy volunteers and embolic signals recorded from a flow phantom were used to characterize the appearance of the two types of event. Characteristics of events, recorded during and immediately after carotid endarterectomy surgery, were compared with those from known sources. Additional information was provided by the RF signal on events recorded during TCD monitoring thus aiding classification. The RF signal may have a role as a "gold standard" for embolus detection. (c) 2005 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:613 / 623
页数:11
相关论文
共 12 条
[1]  
EVANS DH, 1999, TRANSCRANIAL DOPPLER, P141
[2]   Real-time identification and archiving of micro-embolic Doppler signals using a knowledge-based DSP system [J].
Fan, L ;
Evans, DH ;
Naylor, AR ;
Tortoli, P .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2004, 42 (02) :193-200
[3]   Measurement of the speed of sound in ethanol/water mixtures [J].
Martin, K ;
Spinks, D .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (02) :289-291
[4]   Microembolic signal description: A reappraisal based on a customized digital postprocessing system [J].
Mess, WH ;
Willigers, JM ;
Ledoux, LAF ;
Ackerstaff, RGA ;
Hoeks, APG .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (11-12) :1447-1455
[5]   A new algorithm for off-line automated emboli detection based on the pseudo-Wigner power distribution and the dual gate TCD technique [J].
Mess, WH ;
Titulaer, BM ;
Ackerstaff, RGA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (03) :413-418
[6]  
MESS WH, 2003, THESIS U MAASTRICHT
[7]  
MESS WH, 1997, NEW TRENDS CEREBRAL, P355
[8]   Power M-mode Doppler (PMD) for observing cerebral blood flow and tracking emboli [J].
Moehring, MA ;
Spencer, MP .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (01) :49-57
[9]   Validation of a new blood-mimicking fluid for use in Doppler flow test objects [J].
Ramnarine, KV ;
Nassiri, DK ;
Hoskins, PR ;
Lubbers, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (03) :451-459
[10]  
Smith S. W., 1997, SCI ENG GUIDE DIGITA