Spatial phase stepping wavelength meter

被引:4
|
作者
Surrel, Y
García-Márquez, J
Fodor, J
Juncar, P
机构
[1] Conservatoire Natl Arts & Metiers, Inst Natl Metrol, F-75141 Paris, France
[2] Ctr Invest Opt, Leon 37150, Mexico
关键词
phase shifting interferometry; wavemeters; length metrology; uncertainty evaluation; fibre couplers; lasers;
D O I
10.1088/0957-0233/16/3/025
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A new way of evaluating the ratio between a reference wavelength radiation and an unknown wavelength radiation in a two-beam interferometer is proposed here. The advantage of two-beam interferometry is the sinusoidal fringe signal for which precise phase detection algorithms exist. Modem algorithms can cope with different sources of errors, and correct them. We recall the principle of the Michelson-type lambdameter using temporal interference and we introduce the Young-type lambdameter using spatial interference. The Young-type lambdameter is based on the acquisition of the interference pattern from two point sources (e.g. two ends of monomode fibres projected onto a CCD camera). The measurement of an unknown wavelength can be achieved by comparing with a reference wavelength. Accurate interference phase maps can be calculated using -spatial phase shifting. In this way, each small group of contiguous pixels acts as a single interferometer, and the whole set of pixels corresponds to many hundreds or thousands of interferometric measurement system units. The analysis of uncertainties shows that resolutions better than 10(-7) can be achieved. An advantage of the, fibre wavelength metre described here is the, measurement velocity that takes only a few seconds.
引用
收藏
页码:821 / 827
页数:7
相关论文
共 50 条
  • [1] Broadband precision wavelength meter based on a stepping Fabry-Perot interferometer
    Scholl, TJ
    Rehse, SJ
    Holt, RA
    Rosner, SD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3318 - 3326
  • [2] WAVELENGTH METER
    PAUL, J
    BYER, RL
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1976, 66 (04) : 384 - 384
  • [3] Wavelength meter
    Oliver Graydon
    Nature Photonics, 2017, 11 : 532 - 532
  • [4] Wavelength meter
    Graydon, Oliver
    NATURE PHOTONICS, 2017, 11 (09) : 532 - 532
  • [5] A robust spatial phase-stepping ESPI system
    Sesselmann, M
    Goncalves, AA
    LASER METROLOGY FOR PRECISION MEASUREMENT AND INSPECTION IN INDUSTRY, 2001, 4420 : 149 - 154
  • [6] Achromatic phase-shifting for two-wavelength phase-stepping interferometry
    Hariharan, P
    Roy, M
    OPTICS COMMUNICATIONS, 1996, 126 (4-6) : 220 - 222
  • [7] Achromatic phase-shifting for two-wavelength phase-stepping interferometry
    Univ of Sydney
    Opt Commun, 4-6 (220-222):
  • [8] Thickness measurement of transparent plates by wavelength stepping and a phase unwrapping algorithm
    Yu, H.
    Aleksoff, C.
    Ni, J.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (07)
  • [9] An astigmatic wavelength meter
    Dubov, MV
    Klishevich, GV
    Sergienko, VN
    Obukhov, IA
    Turchin, AV
    Chernomorets, MP
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2001, 44 (04) : 537 - 543
  • [10] An Astigmatic Wavelength Meter
    M. V. Dubov
    G. V. Klishevich
    V. N. Sergienko
    I. A. Obukhov
    A. V. Turchin
    M. P. Chernomorets
    Instruments and Experimental Techniques, 2001, 44 : 537 - 543