摘要
Deformable image registration of four head and neck cancer patients has been conducted using a biomechanical-based model. Patient-specific 3D finite element models have been developed using CT and cone-beam CT image data of the planning and a radiation treatment session. The model consists of seven vertebrae (C1 to C7), mandible, larynx, left and right parotid glands, tumor and body. Different combinations of boundary conditions are applied in the model in order to find the configuration with a minimum registration error. Each vertebra in the planning session is individually aligned with its correspondence in the treatment session. Rigid alignment is used for each individual vertebra and the mandible since no deformation is expected in the bones. In addition, the effect of morphological differences in the external body between the two image sessions is investigated. The accuracy of the registration is evaluated using the tumor and both parotid glands by comparing the calculated Dice similarity index of these structures following deformation in relation to their true surface defined in the image of the second session. The registration is improved when the vertebrae and mandible are aligned in the two sessions with the highest average Dice index of 0.86 +/- 0.08, 0.84 +/- 0.11 and 0.89 +/- 0.04 for the tumor, left and right parotid glands, respectively. The accuracy of the center of mass location of tumor and parotid glands is also improved by deformable image registration where the errors in the tumor and parotid glands decrease from 4.0 +/- 1.1, 3.4 +/- 1.5 and 3.8 +/- 0.9 mm using rigid registration to 2.3 +/- 1.0, 2.5 +/- 0.8 and 2.0 +/- 0.9 mm in the deformable image registration when alignment of vertebrae and mandible is conducted in addition to the surface projection of the body.
引用
收藏
页码:6491 / 6500
页数:10
相关论文
共 28 条
[1]   Contact surface and material nonlinearity modeling of human lungs [J].
Al-Mayah, A. ;
Moseley, J. ;
Brock, K. K. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (01) :305-317
[2]  
[Anonymous], 2005, The ITK Software Guide
[3]   Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system [J].
Barker, JL ;
Garden, AS ;
Ang, KK ;
O'Daniel, JC ;
Wang, H ;
Court, LE ;
Morrison, WH ;
Rosenthal, DI ;
Chao, KSC ;
Tucker, SL ;
Mohan, R ;
Dong, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04) :960-970
[4]   Evaluation of three-dimensional finite element-based deformable registration of pre- and intraoperative prostate imaging [J].
Bharatha, A ;
Hirose, M ;
Hata, N ;
Warfield, SK ;
Ferrant, M ;
Zou, KH ;
Suarez-Santana, E ;
Ruiz-Alzola, J ;
D'Amico, A ;
Cormack, RA ;
Kikinis, R ;
Jolesz, FA ;
Tempany, CMC .
MEDICAL PHYSICS, 2001, 28 (12) :2551-2560
[5]   Dose-volume modeling of salivary function in patients with head-and-neck cancer receiving radiotherapy [J].
Blanco, AI ;
Chao, KSC ;
El Naqa, I ;
Franklin, GE ;
Zakarian, K ;
Vicic, M ;
Deasy, JO .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (04) :1055-1069
[6]   A ray-driven approach to generate a deformed image for image-guided radiotherapy [J].
Brock, K ;
Moseley, J ;
Moseley, D ;
Jaffray, D .
RADIOTHERAPY AND ONCOLOGY, 2005, 76 :S129-S130
[7]   Accuracy of finite element model-based multi-organ deformable image registration [J].
Brock, KK ;
Sharpe, MB ;
Dawson, LA ;
Kim, SM ;
Jaffray, DA .
MEDICAL PHYSICS, 2005, 32 (06) :1647-1659
[8]   Technical note: Creating a four-dimensional model of the liver using finite element analysis [J].
Brock, KK ;
Hollister, SJ ;
Dawson, LA ;
Balter, JM .
MEDICAL PHYSICS, 2002, 29 (07) :1403-1405
[9]   Application of soft tissue modelling to image-guided surgery [J].
Carter, TJ ;
Sermesant, M ;
Cash, DM ;
Barratt, DC ;
Tanner, C ;
Hawkes, DJ .
MEDICAL ENGINEERING & PHYSICS, 2005, 27 (10) :893-909
[10]   Compensating for intraoperative soft-tissue deformations using incomplete surface data and finite elements [J].
Cash, DM ;
Miga, MI ;
Sinha, TK ;
Galloway, RL ;
Chapman, WC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (11) :1479-1491