Reliability of stress radiography for evaluation of posterior knee laxity

被引:76
作者
Schulz, MS
Russe, K
Lampakis, G
Strobel, MJ
机构
[1] Orthopaed Gemeinschaftspraxis Straubing, D-94315 Straubing, Germany
[2] Univ Hosp Essen, Dept Trauma Surg, Essen, Germany
关键词
posterior cruciate ligament (PCL); stress radiography; posterior tibial displacement; reliability;
D O I
10.1177/0363546504269723
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Although stress radiography has been recommended for quantifying posterior tibial displacement in knees with posterior cruciate ligament insufficiency, the intratester reliability and intertester reliability of this measurement method have not been evaluated. Hypothesis: Stress radiography is a reproducible measurement method in the assessment of posterior knee laxity in patients with posterior cruciate ligament lesions. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: Stress radiographs of 787 patients with suspected posterior cruciate ligament lesions taken using the Telos device were evaluated independently by 3 testers: 2 of the testers were clinically experienced in the evaluation of stress radiographs, and 1 tester was a novice tester. Change in mean, standard error of measurement with calculated confidence intervals, and intraclass correlation coefficients were determined to assess intratester and intertester reliability. Results: There was no significant intratester change in mean. Intratester standard error of measurement was 1.03 mm; 95% confidence intervals were +/- 2.02 mm for a single measurement and +/- 2.86 mm for a change in measurement. The intratester intraclass correlation coefficient was 0.95. Intertester reliability revealed a significant change in mean between the experienced testers and the novice tester (P <.001). There was no substantial difference for the standard error of measurement of each tester. The mean intertester standard error of measurement was 1.41 mm; 95% confidence intervals were +/- 2.77 mm for a single measurement and +/- 3.91 mm for a change in measurement. The intertester intraclass correlation coefficient was 0.91. Conclusion: Stress radiography was found to be a measurement method with a useful reliability for evaluation of posterior laxity in patients with posterior cruciate ligament lesions. The reproducibility of stress radiography may be influenced by multiple variables, and standardized methods are needed to minimize measurement error.
引用
收藏
页码:502 / 506
页数:5
相关论文
共 23 条
[1]  
ANDREWS JR, 1994, CLIN SPORT MED, V13, P519
[2]   Posterior cruciate ligament reconstruction using single-bundle patella tendon graft with tibial inlay fixation - 2-to 10-year follow-up [J].
Cooper, DE ;
Stewart, D .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2004, 32 (02) :346-360
[3]   CURRENT CONCEPTS REVIEW - INJURIES OF THE POSTERIOR CRUCIATE LIGAMENT [J].
COVEY, DC ;
SAPEGA, AA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (09) :1376-1386
[4]   USE OF THE QUADRICEPS ACTIVE TEST TO DIAGNOSE POSTERIOR CRUCIATE-LIGAMENT DISRUPTION AND MEASURE POSTERIOR LAXITY OF THE KNEE [J].
DANIEL, DM ;
STONE, ML ;
BARNETT, P ;
SACHS, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :386-391
[5]   Arthrometric evaluation of posterior cruciate ligament injuries [J].
Eakin, CL ;
Cannon, WD .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1998, 26 (01) :96-102
[6]   Combined posterior cruciate ligament-posterolateral reconstructions with Achilles tendon allograft and biceps femoris tendon tenodesis: 2-to 10-year follow-up [J].
Fanelli, GC ;
Edson, CJ .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2004, 20 (04) :339-345
[7]   Evaluation and treatment of posterior cruciate ligament injuries [J].
Harner, CD ;
Hoher, J .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1998, 26 (03) :471-482
[8]   Diagnosis of complete and partial posterior cruciate ligament ruptures - Stress radiography compared with KT-1000 arthrometer and posterior drawer testing [J].
Hewett, TE ;
Noyes, FR ;
Lee, MD .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1997, 25 (05) :648-655
[9]   Measures of reliability in sports medicine and science [J].
Hopkins, WG .
SPORTS MEDICINE, 2000, 30 (01) :1-15
[10]  
Hopkins WG, NEW VIEW STAT