Contrast enhanced imaging with a stationary digital breast tomosynthesis system

被引:1
|
作者
Puett, Connor [1 ]
Calliste, Jabari [1 ]
Wu, Gongting [1 ]
Inscoe, Christina R. [1 ]
Lee, Yueh Z. [1 ]
Zhou, Otto [1 ]
Lu, Jianping [1 ]
机构
[1] Univ North Carolina Chapel Hill, Chapel Hill, NC 27599 USA
来源
MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING | 2017年 / 10132卷
关键词
digital breast tomosynthesis; DBT; contrast-enhanced breast imaging; CE-DBT; scatter correction; carbon nanotubes; CNT; SCATTER CORRECTION; RECONSTRUCTION; MAMMOGRAPHY;
D O I
10.1117/12.2254348
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Digital breast tomosynthesis (DBT) captures some depth information and thereby improves the conspicuity of breast lesions, compared to standard mammography. Using contrast during DBT may also help distinguish malignant from benign sites. However, adequate visualization of the low iodine signal requires a subtraction step to remove background signal and increase lesion contrast. Additionally, attention to factors that limit contrast, including scatter, noise, and artifact, are important during the image acquisition and post-acquisition processing steps. Stationary DBT (sDBT) is an emerging technology that offers a higher spatial and temporal resolution than conventional DBT. This phantom-based study explored contrast-enhanced sDBT (CE sDBT) across a range of clinically-appropriate iodine concentrations, lesion sizes, and breast thicknesses. The protocol included an effective scatter correction method and an iterative reconstruction technique that is unique to the sDBT system. The study demonstrated the ability of this CE sDBT system to collect projection images adequate for both temporal subtraction (TS) and dual-energy subtraction (DES). Additionally, the reconstruction approach preserved the improved contrast-to-noise ratio (CNR) achieved in the subtraction step. Finally, scatter correction increased the iodine signal and CNR of iodine-containing regions in projection views and reconstructed image slices during both TS and DES. These findings support the ongoing study of sDBT as a potentially useful tool for contrast-enhanced breast imaging and also highlight the significant effect that scatter has on image quality during DBT.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] A scatter correction method for contrast-enhanced dual-energy digital breast tomosynthesis
    Lu, Yihuan
    Peng, Boyu
    Lau, Beverly A.
    Hu, Yue-Houng
    Scaduto, David A.
    Zhao, Wei
    Gindi, Gene
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (16) : 6323 - 6354
  • [2] A simple scatter correction method for dual energy contrast-enhanced digital breast tomosynthesis
    Lu, Yihuan
    Lau, Beverly
    Hu, Yue-Houng
    Zhao, Wei
    Gindi, Gene
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [3] A Stationary Digital Breast Tomosynthesis Scanner
    Qian, Xin
    Tucker, Andrew
    Gidcumb, Emily
    Lu, Jianping
    Zhou, Otto
    Spronk, Derrek
    Sprenger, Frank
    Zhang, Yiheng
    Kennedy, Don
    Farbizio, Tom
    Jing, Zhenxue
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [4] Validation of Contrast-Enhanced Mammography as Breast Imaging Modality Compared to Standard Mammography and Digital Breast Tomosynthesis
    Bartolovic, Nina
    Peterko, Ana Car
    Avirovic, Manuela
    Ritosa, Doris Segota
    Dujmic, Emina Grgurevic
    Zujic, Petra Valkovic
    DIAGNOSTICS, 2024, 14 (14)
  • [5] Quantification of contrast-enhanced digital breast tomosynthesis
    Maidment, A. D. A.
    Carton, A. -K.
    Chen, S.
    Conant, E. F.
    Schnal, M.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2006, 1 : 12 - 14
  • [6] Quantification for contrast-enhanced digital breast tomosynthesis
    Carton, Ann-Katherine
    Li, Jingjing
    Albert, Michael
    Chen, Sara
    Maidment, Andrew D. A.
    MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [7] System Calibration for Quantitative Contrast-Enhanced Digital Breast Tomosynthesis (CEDBT)
    Hill, Melissa L.
    Mainprize, James G.
    Yaffe, Martin J.
    BREAST IMAGING, IWDM 2016, 2016, 9699 : 645 - 653
  • [8] Dependence of Contrast-Enhanced Lesion Detection in Contrast-Enhanced Digital Breast Tomosynthesis on Imaging Chain Design
    Scaduto, David A.
    Hu, Yue-Houng
    Lu, Yihuan
    Huang, Hailiang
    Liu, Jingxuan
    Rinaldi, Kim
    Gindi, Gene
    Fisher, Paul R.
    Zhao, Wei
    BREAST IMAGING, IWDM 2016, 2016, 9699 : 136 - 144
  • [9] Dependency of image quality on system configuration parameters in a stationary digital breast tomosynthesis system
    Tucker, Andrew W.
    Lu, Jianping
    Zhou, Otto
    MEDICAL PHYSICS, 2013, 40 (03)
  • [10] Design and feasibility studies of a stationary digital breast tomosynthesis system
    Yang, G.
    Qian, X.
    Phan, T.
    Sprenger, F.
    Sultana, S.
    Calderon-Colon, X.
    Kearse, B.
    Spronk, D.
    Lu, J.
    Zhou, O.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S220 - S223