CALIBRATION AND TESTS OF COMMERCIAL WIRELESS INFRARED THERMOMETERS

被引:12
作者
Colaizzi, P. D. [1 ]
O'Shaughnessy, S. A. [1 ]
Evett, S. R. [1 ]
机构
[1] ARS, USDA, Bushland, TX USA
关键词
Canopy temperature; Crop management; Evapotranspiration; Irrigation; Remote sensing; Sensors; MEASURING SURFACE-TEMPERATURE; IRRIGATION; RADIOMETER; FIELD; EVAPOTRANSPIRATION; THRESHOLD; STRESS;
D O I
10.13031/aea.12577
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Applications of infrared thermometers (IRTs) in large agricultural fields require wireless data transmission, and IRT target temperature should have minimal sensitivity to internal detector temperature. To meet these objectives, a prototype wireless IRT system was developed at USDA Agricultural Research Service, Bushland, Texas, and commercialized by Dynamax, Inc., Houston, Texas. The objective of this article was to calibrate and test the Dynamax, Inc. system. Following deployment in an irrigated field during the 2015 crop season, 26 IRTs were calibrated and tested in a temperature-controlled room. The IRTs measured a black body target temperature controlled at 15 degrees C to 55 degrees C in 5 degrees C increments, and for each range of black body temperatures, ambient room temperatures were controlled at 15 degrees C, 20 degrees C, 25 degrees C, 35 degrees C, and 45 degrees C under isothermal and steady-state conditions. Discrepancies between uncalibrated IRT and black body temperatures varied by IRT and had root mean squared errors (RMSE) between 0.25 degrees C and 1.51 degrees C, mean absolute errors (MAE) between 0.19 degrees C and 1.17 degrees C, and mean bias errors (MBE) between -0.66 degrees C and 0.16 degrees C. A calibration equation was derived from the longwave radiation energy balance of the IRT internal detector, and sensor-specific calibrations reduced discrepancies for all IRTs, with RMSE between 0.16 degrees C and 0.28 degrees C, MAE between 0.12 degrees C and 0.21 degrees C, and absolute MBE less than 0.05 degrees C. A generic calibration was derived by pooling all sensor-specific calibrations, and reduced discrepancies for all but five IRTs, but these were very marginal compared with no calibration. Therefore, the generic calibration did not appear justified, but sensor-specific calibrations were justified for most IRTs. The IRTs were again deployed in the irrigated field and measured corn canopy temperature in 2016. Crop evapotranspiration (ETc) was calculated using measurements from one IRT and compared to ETc measured by a large weighing lysimeter. The choice of calibration (none, generic, or sensor-specific) had little impact on calculated ETc, which was likely related to a limited range of target and sensor body temperature differences in the field (mostly +/- 10 degrees C), in contrast to those in the temperature-controlled room (up to +/- 40 degrees C)
引用
收藏
页码:647 / 658
页数:12
相关论文
共 50 条
  • [1] DATA QUALITY CONTROL FOR STATIONARY INFRARED THERMOMETERS VIEWING CROPS
    Colaizzi, Paul D.
    O'Shaughnessy, Susan A.
    Evett, Steven R.
    Marek, Gary W.
    Brauer, David
    Copeland, Karen S.
    Ruthardt, Brice B.
    APPLIED ENGINEERING IN AGRICULTURE, 2023, 39 (04) : 427 - 438
  • [2] Crop evapotranspiration calculation using infrared thermometers aboard center pivots
    Colaizzi, Paul D.
    O'Shaughnessy, Susan A.
    Evett, Steve R.
    Mounce, Ryan B.
    AGRICULTURAL WATER MANAGEMENT, 2017, 187 : 173 - 189
  • [3] Assessment of Hysteresis Uncertainty in the Calibration of Platinum Resistance Thermometers
    Yang, Inseok
    Lee, Young Hee
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2023, 44 (08)
  • [4] MAIZE EVAPOTRANSPIRATION ESTIMATES USING PLANET DOVE MINI-SATELLITES AND FIELD-LEVEL INFRARED THERMOMETERS
    Chavez, Jose Luis
    Zhang, Huihui
    Brown, Ansley J.
    Andales, Allan A.
    Costa-Filho, Edson
    APPLIED ENGINEERING IN AGRICULTURE, 2024, 40 (01) : 69 - 78
  • [5] Real-time mapping of crop canopy temperature using a wireless network of infrared thermometers on a central pivot
    Jimenez, Andres-F
    V. Ortiz, Brenda
    Lena, Bruno P.
    MEASUREMENT, 2024, 230
  • [6] New non-water-stressed baselines for irrigation scheduling with infrared thermometers
    Alves, I
    Pereira, LS
    WATER AND THE ENVIRONMENT: INNOVATIVE ISSUES IN IRRIGATION AND DRAINAGE, 1998, : 180 - 188
  • [7] Performance of Different Light Sources for the Absolute Calibration of Radiation Thermometers
    M. J. Martín
    J. M. Mantilla
    D. del Campo
    M. L. Hernanz
    A. Pons
    J. Campos
    International Journal of Thermophysics, 2017, 38
  • [8] Performance of Different Light Sources for the Absolute Calibration of Radiation Thermometers
    Martin, M. J.
    Mantilla, J. M.
    del Campo, D.
    Hernanz, M. L.
    Pons, A.
    Campos, J.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2017, 38 (09)
  • [9] A Crop Water Stress Index for Hazelnuts Using Low-Cost Infrared Thermometers
    Mccauley, Dalyn
    Keller, Sadie
    Transue, Kody
    Wiman, Nik
    Nackley, Lloyd
    SENSORS, 2024, 24 (23)
  • [10] Prelaunch Radiometric Calibration and Uncertainty Analysis of Landsat Thermal Infrared Sensor 2
    Pearlman, Aaron
    Montanaro, Matthew
    Efremova, Boryana
    McCorkel, Joel
    Wenny, Brian
    Lunsford, Allen
    Reuter, Dennis
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2021, 59 (04): : 2715 - 2726