In-beam PET measurement of 7Li3+ irradiation induced β+-activity

被引:23
|
作者
Priegnitz, M. [1 ]
Moeckel, D. [1 ]
Parodi, K. [2 ]
Sommerer, F. [3 ]
Fiedler, F. [1 ]
Enghardt, W. [1 ,4 ]
机构
[1] Forschungszentrum, Inst Radiat Phys, Div Radiat Phys, D-01314 Dresden, Germany
[2] Heidelberg Ion Therapy Ctr, D-69120 Heidelberg, Germany
[3] CERN, CH-1211 Geneva 23, Switzerland
[4] Tech Univ Dresden, Univ Hosp, D-01307 Dresden, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2008年 / 53卷 / 16期
关键词
D O I
10.1088/0031-9155/53/16/015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
At present positron emission tomography (PET) is the only feasible method of an in situ and non-invasive monitoring of patient irradiation with ions. At the experimental carbon ion treatment facility of the Gesellschaft fur Schwerionenforschung (GSI) Darmstadt an in-beam PET scanner has been integrated into the treatment site and lead to a considerable quality improvement of the therapy. Since ions other than carbon are expected to come into operation in future patient treatment facilities, it is highly desirable to extend in-beam PET also to other therapeutic relevant ions, e. g. (7)Li. Therefore, by means of the in-beam PET scanner at GSI the beta(+)- activity induced by (7)Li(3+) ions has been investigated for the first time. Targets of PMMA, water, graphite and polyethylene were irradiated with monoenergetic, pencil-like beams of (7)Li(3+) with energies between 129.1 A MeV and 205.3 A MeV and intensities ranging from 3.0 x 10(7) to 1.9 x 10(8) ions s(-1). This paper presents the measured beta(+)-activity profiles as well as depth dependent thick target yields which have been deduced from the experimental data. The beta(+)- activity induced by (7)Li ions was found to be a factor of 1.76 higher than the one induced by (12)C ions at the same physical dose and particle range.
引用
收藏
页码:4443 / 4453
页数:11
相关论文
共 50 条
  • [1] Dosimetry by Means of In-Beam PET with RI Beam Irradiation
    Nakajima, Yasunori
    Hirano, Yoshiyuki
    Tashima, Hideaki
    Yoshida, Eiji
    Sato, Shinji
    Lnaniwa, Taku
    Kohno, Toshiyuki
    Sihver, Lembit
    Yamaya, Taiga
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [2] In-beam PET measurements of biological half-lives of 12C irradiation induced β+-activity
    Fiedler, Fine
    Priegnitz, Marlen
    Juelich, Robert
    Pawelke, Joerg
    Crespo, Paulo
    Parodi, Katia
    Poenisch, Falk
    Enghardt, Wolfgang
    ACTA ONCOLOGICA, 2008, 47 (06) : 1077 - 1086
  • [3] First in-beam PET measurement of β+ radioactivity induced by hard photon beams
    Kluge, T.
    Moeckel, D.
    Pawelke, J.
    Enghardt, W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (20): : N467 - N473
  • [4] Preliminary Design of a Hybrid Ion Source for 7Li3+ Generation
    Zhang, Jingfeng
    Peng, Shixiang
    Ren, Haitao
    Xu, Yuan
    Zhang, Ailin
    Zhang, Tao
    Wu, Wenbin
    Wen, Jiamei
    Guo, Zhiyu
    Chen, Jia'er
    PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON ION SOURCES, 2018, 2011
  • [5] In-beam PET measurements of β+ radioactivity induced by proton beams
    Parodi, K
    Enghardt, W
    Haberer, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (01): : 21 - 36
  • [6] Study of In-Vivo Kinetics of Induced Particles :In-Beam PET Measurement of Washout in Rabbits Using 150 Ion Beam
    Toramatsu, C.
    Wakizaka, H.
    Mohammadi, A.
    Nitta, M.
    Iwao, Y.
    Nishikido, F.
    Tashima, H.
    Yoshida, E.
    Kitagawa, A.
    Karasawa, K.
    Yamaya, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E510 - E510
  • [7] The feasibility of in-beam PET for therapeutic beams of 3He
    Fiedler, Fine
    Crespo, Paulo
    Parodi, Katia
    Sellesk, Marlen
    Enghardt, Wolfgang
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (04) : 2252 - 2259
  • [8] The feasibility of in-beam PET for therapeutic beams of 3He
    Fiedler, Fine
    Crespo, Paulo
    Parodi, Katia
    Sellesk, Marlen
    Enghardt, Wolfgang
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2757 - 2760
  • [9] In-Beam PET Imaging with Depth-Of-Interaction Measurement for Accurate Proton Beam-Range Verification
    Shao, Y.
    Sun, X.
    Lou, K.
    Zhu, X.
    Mirkovic, D.
    Poenisch, F.
    Grosshans, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [10] First 4D In-beam PET Measurement for Beam Tracking of a Moving Phantom with a Scanned Carbon Ion Beam
    Parodi, K.
    Saito, N.
    Richter, C.
    Chaudhri, N.
    Enghardt, W.
    Rietzel, E.
    Bert, C.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3794 - +