Electrochemical Assays and Immunoassays of the Myeloperoxidase/SCN-/H2O2 System

被引:26
作者
Bekhit, Michael [1 ]
Gorski, Waldemar [1 ]
机构
[1] Univ Texas San Antonio, Dept Chem, One UTSA Circle, San Antonio, TX 78249 USA
关键词
HYDROGEN-PEROXIDE; BIOMARKERS; IMMUNOSENSOR; NANOTUBES; OXIDATION; ELECTRODE;
D O I
10.1021/acs.analchem.8b05855
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Strategies to detect and characterize myeloperoxidase (MPO) are needed, given that this "split personality" enzyme kills harmful microorganisms but also damages a host tissue. Here, we describe electrochemical approaches to measure MPO by using the pseudohalogenation (MPO/SCN-/H2O2) and catalase-like (MPO/H2O2) cycles. Their kinetics were determined by monitoring the consumption of H2O2 with a nitrogen-doped carbon nanotubes (N-CNT) electrode, which could detect 0.50 mu M H2O2 at -0.20 V. The unique design of internally calibrated electrochemical continuous enzyme assay (ICECEA) and electrode stability allowed use of one N-CNT electrode for over half a year to reliably determine MPO. The kinetic measurements showed that (a) SCN- did not affect the affinity of MPO for H2O2, (b) catalase-like cycle was slower, and (c) MPO retained enzymatically active conformation after complexation with its antibody Ab both in a solution and on the surface of an antibody dipstick (d/Ab). The homogeneous assays could detect 5.2 mu g L-1 MPO (35 pM) via a faster cycle. The heterogeneous immunoassays with the capture of MPO on d/Ab could detect 60 mu g L-1, which was suitable for the accurate detection of MPO in human saliva (101% recovery). Replacing a detection antibody of ELISA with ICECEA as a signal transducer for immunoassays offers a rapid method for the selective determination of enzymes; for example, time of MPO quantification was cut from 3-4 h (sandwich ELISA) to, similar to 20 min (ICECEA-dipstick).
引用
收藏
页码:3163 / 3169
页数:7
相关论文
共 28 条
[21]   Electrochemically Prepared Three-dimensional Porous Nitrogen-doped Graphene Modified Electrode for Non-enzymatic Detection of Hydrogen Peroxide [J].
Qi, Yamin ;
Bai, Jie ;
Ding, Xiaoteng ;
Zhang, Hui-Min .
ELECTROANALYSIS, 2017, 29 (09) :2083-2089
[22]   Electrochemical Lateral Flow Devices: Towards Rapid Immunomagnetic Assays [J].
Ruiz-Vega, Gisela ;
Kitsara, Maria ;
Aller Pellitero, Miguel ;
Baldrich, Eva ;
Javier del Campo, F. .
CHEMELECTROCHEM, 2017, 4 (04) :880-889
[23]   New insights into thiocyanate oxidation by human myeloperoxidase [J].
Schlorke, Denise ;
Flemmig, Joerg ;
Gau, Jana ;
Furtmueller, Paul G. ;
Obinger, Christian ;
Arnhold, Juergen .
JOURNAL OF INORGANIC BIOCHEMISTRY, 2016, 162 :117-126
[24]   Electrocatalytic sensing of hydrogen peroxide using a screen printed carbon electrode modified with nitrogen-doped graphene nanoribbons [J].
Shi, Libo ;
Niu, Xiangheng ;
Liu, Tingting ;
Zhao, Hongli ;
Lan, Minbo .
MICROCHIMICA ACTA, 2015, 182 (15-16) :2485-2493
[25]   Amperometric myeloperoxidase immunoassay based on the use of CuPdPt nanowire networks [J].
Wen, Yilin ;
Yuan, Jianyong ;
Chen, Jun ;
Zhao, Yilin ;
Niu, Yazhen ;
Yu, Chao .
MICROCHIMICA ACTA, 2018, 185 (01)
[26]  
Weyer R, 1982, BIOCHIM BIOPHYS ACTA, V709, P212
[27]   On the Direct Electron Transfer, Sensing, and Enzyme Activity in the Glucose Oxidase/Carbon Nanotubes System [J].
Wooten, Marilyn ;
Karra, Sushma ;
Zhang, Maogen ;
Gorski, Waldemar .
ANALYTICAL CHEMISTRY, 2014, 86 (01) :752-757
[28]   Rapid Electrochemical Enzyme Assay with Enzyme-Free Calibration [J].
Zhang, Maogen ;
Karra, Sushma ;
Gorski, Waldemar .
ANALYTICAL CHEMISTRY, 2013, 85 (12) :6026-6032