Long-term safety and absorption assessment of a novel bioresorbable nitrided iron scaffold in porcine coronary artery

被引:41
作者
Zheng, Jian-Feng [1 ]
Xi, Zi-Wei [1 ]
Li, Yang [1 ]
Li, Jia-Nan [7 ]
Qiu, Hong [1 ]
Hu, Xiao-Ying [1 ]
Luo, Tong [1 ]
Wu, Chao [1 ]
Wang, Xin [2 ]
Song, Lai-Feng [3 ]
Li, Li [3 ]
Qi, Hai-Ping [4 ]
Zhang, Gui [4 ]
Qin, Li [4 ]
Zhang, Wan-Qian [4 ]
Shi, Xiao-Li [5 ]
Wang, Shu-Han [6 ]
Zhang, De-Yuan [4 ]
Xu, Bo [1 ]
Gao, Run-Lin [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Fuwai Hosp, Natl Ctr Cardiovasc Dis, Dept Cardiol, Beijing, Peoples R China
[2] Chinese Acad Med Sci & Peking Union Med Coll, Fuwai Hosp, Beijing Key Lab Preclin Res & Evaluat Cardiovasc, Natl Ctr Cardiovasc Dis,Anim Expt Ctr, Beijing, Peoples R China
[3] Chinese Acad Med Sci & Peking Union Med Coll, Fuwai Hosp, Natl Ctr Cardiovasc Dis, Dept Pathol, Beijing, Peoples R China
[4] Biotyx Med Shenzhen Co Ltd, R&D Ctr, Shenzhen, Peoples R China
[5] Lifetech Sci Shenzhen Co Ltd, Natl & Local Joint Engn Lab Intervent Med Biotech, Shenzhen, Peoples R China
[6] Shen Zhen Testing Ctr Med Devices, Shenzhen, Peoples R China
[7] Capital Med Univ, Beijing Tiantan Hosp, Dept Cardiol & Macrovasc Dis, Beijing, Peoples R China
基金
国家重点研发计划;
关键词
Bioresorbable scaffold; Nitrided iron bioresorbable coronary scaffold; Preclinical study; Completely bioresorbable; ABSORBABLE METAL SCAFFOLD; SUSTAINED SAFETY; BIOSOLVE-II; STENT; BIOCOMPATIBILITY; PERFORMANCE; THROMBOSIS; OUTCOMES;
D O I
10.1016/j.bioactmat.2022.01.005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aimed to investigate the long-term biocompatibility, safety, and degradation of the ultrathin nitrided iron bioresorbable scaffold (BRS) in vivo, encompassing the whole process of bioresorption in porcine coronary arteries. Fifty-two nitrided iron scaffolds (strut thickness of 70 mu m) and 28 Vision Co-Cr stents were randomly implanted into coronary arteries of healthy mini-swine. The efficacy and safety of the nitrided iron scaffold were comparable with those of the Vision stentwithin 52 weeks after implantation. In addition, the long-term biocompatibility, safety, and bioresorption of the nitrided iron scaffold were evaluated by coronary angiography, optical coherence tomography, micro-computed tomography, scanning electron microscopy, energy dispersive spectrometry and histopathological evaluations at 4, 12, 26, 52 weeks and even at 7 years after implantation. In particular, a large number of struts were almost completely absorbed in situ at 7 years follow-up, which were first illustrated in this study. The lymphatic drainage pathway might serve as the potential clearance way of iron and its corrosion products.
引用
收藏
页码:496 / 505
页数:10
相关论文
共 32 条
[11]  
Lide D.R., 2003, HDB CHEM PHYS, V84th, P688
[12]   In vivo degradation and endothelialization of an iron bioresorbable scaffold [J].
Lin, Wenjiao ;
Zhang, Hongjie ;
Zhang, Wanqian ;
Qi, Haiping ;
Zhang, Gui ;
Qian, Jie ;
Li, Xin ;
Qin, Li ;
Li, Haifeng ;
Wang, Xiang ;
Qiu, Hong ;
Shi, Xiaoli ;
Zheng, Wei ;
Zhang, Deyuan ;
Gao, Runlin ;
Ding, Jiandong .
BIOACTIVE MATERIALS, 2021, 6 (04) :1028-1039
[13]   Long-term in vivo corrosion behavior, biocompatibility and bioresorption mechanism of a bioresorbable nitrided iron scaffold [J].
Lin, Wenjiao ;
Qin, Li ;
Qi, Haiping ;
Zhang, Deyuan ;
Zhang, Gui ;
Gao, Runlin ;
Qiu, Hong ;
Xia, Ying ;
Cao, Ping ;
Wang, Xiang ;
Zheng, Wei .
ACTA BIOMATERIALIA, 2017, 54 :454-468
[14]   Cytotoxicity and its test methodology for a bioabsorbable nitrided iron stent [J].
Lin, Wenjiao ;
Zhang, Gui ;
Cao, Ping ;
Zhang, Deyuan ;
Zheng, Yufeng ;
Wu, Rangxiu ;
Qin, Li ;
Wang, Geqi ;
Wen, Taoyuan .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2015, 103 (04) :764-776
[15]   Initial findings of impact of strut width on stent coverage and apposition of sirolimus-eluting stents assessed by optical coherence tomography [J].
Nakatani, Shimpei ;
Nishino, Masami ;
Taniike, Masayuki ;
Makino, Nobuhiko ;
Kato, Hiroyasu ;
Egami, Yasuyuki ;
Shutta, Ryu ;
Tanouchi, Jun ;
Yamada, Yoshio .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (05) :776-781
[16]   Coronary Responses and Differential Mechanisms of Late Stent Thrombosis Attributed to First-Generation Sirolimus- and Paclitaxel-Eluting Stents [J].
Nakazawa, Gaku ;
Finn, Aloke V. ;
Vorpahl, Marc ;
Ladich, Elena R. ;
Kolodgie, Frank D. ;
Virmani, Renu .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (04) :390-398
[17]   The Evolving Role of Inflammatory Biomarkers in Risk Assessment After Stent Implantation [J].
Niccoli, Giampaolo ;
Montone, Rocco A. ;
Ferrante, Giuseppe ;
Crea, Filippo .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (22) :1783-1793
[18]   Impact of Locally Administered Carboxydextran-Coated Super-Paramagnetic Iron Nanoparticles on Cellular Immune Function [J].
Pedro, Luisa ;
Harmer, Quentin ;
Mayes, Eric ;
Shields, Jacqueline D. .
SMALL, 2019, 15 (20)
[19]   A novel approach to temporary stenting:: degradable cardiovascular stents produced from corrodible metal -: results 6-18 months after implantation into New Zealand white rabbits [J].
Peuster, M ;
Wohlsein, P ;
Brügmann, M ;
Ehlerding, M ;
Seidler, K ;
Fink, C ;
Brauer, H ;
Fischer, A ;
Hausdorf, G .
HEART, 2001, 86 (05) :563-569
[20]   Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta [J].
Peuster, Matthias ;
Hesse, Carola ;
Schloo, Tirza ;
Fink, Christoph ;
Beerbaum, Philipp ;
von Schnakenburg, Christian .
BIOMATERIALS, 2006, 27 (28) :4955-4962