Colorectal endoscopic submucosal dissection using novel articulating devices: a comparative study in a live porcine model

被引:10
作者
Okamoto, Yasuharu [1 ]
Nakadate, Ryu [2 ]
Nakamura, Shotaro [3 ]
Arata, Jumpei [4 ]
Oguri, Susumu [5 ]
Moriyama, Tomohiko [1 ]
Esaki, Motohiro [1 ]
Iwasa, Tsutomu [2 ,6 ]
Ohuchida, Kenoki [5 ,7 ]
Akahoshi, Tomohiko [5 ]
Ikeda, Tetsuo [5 ]
Kitazono, Takanari [1 ]
Hashizume, Makoto [2 ,5 ,8 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Med & Clin Sci, Fukuoka, Fukuoka, Japan
[2] Kyushu Univ, Ctr Adv Med Innovat, Fukuoka, Fukuoka, Japan
[3] Iwate Med Univ, Dept Internal Med, Div Gastroenterol, Morioka, Iwate, Japan
[4] Kyushu Univ, Dept Mech Engn, Fac Engn, Fukuoka, Fukuoka, Japan
[5] Kyushu Univ, Grad Sch Med Sci, Dept Adv Med Initiat, Fukuoka, Fukuoka, Japan
[6] Kyushu Univ, Grad Sch Med Sci, Dept Med & Bioregulatory Sci, Fukuoka, Fukuoka, Japan
[7] Kyushu Univ, Grad Sch Med Sci, Dept Surg & Oncol, Fukuoka, Fukuoka, Japan
[8] Kyushu Univ, Fac Med Sci, Dept Adv Med Initiat, Higashi Ku, 3-1-1 Maidashi, Fukuoka, Fukuoka 8128582, Japan
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2019年 / 33卷 / 02期
基金
日本学术振兴会;
关键词
Endoscopic submucosal dissection; ESD; Novel device; Articulating device; Standard endoscope; Colon; ESD;
D O I
10.1007/s00464-018-6408-5
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background and aimsColonic endoscopic submucosal dissection (ESD) is time-consuming and bears a high risk of perforation. The aim of the present study was to compare the safety and efficacy between novel articulating devices and conventional ESD in live porcine colon models.MethodsThirty ESDs in ten pigs were carried out at three different locations (15, 25, and 35cm from the anus) by the conventional method (n=15) and by the new method (n=15). Procedure times, adverse events (perforation, bleeding), and damage to the muscular layer were recorded, and the ESD time per unit area of the specimens was calculated.ResultsThe perforation rate using the conventional method was 6.7% (1/15), whereas that using the new method was 0.0%. The number of sites of muscular damage was significantly lower in the new than conventional method (6 vs. 37, respectively; P=0.024). The mean procedure time was significantly shorter in the new than conventional method (4.62.0 vs. 7.0 +/- 4.1min/cm(2), respectively; P=0.042).Conclusions Use of the new ESD method allows for reduced adverse events and a shortened resection time.
引用
收藏
页码:651 / 657
页数:7
相关论文
共 15 条
[1]   Indications and Techniques for Endoscopic Submucosal Dissection [J].
Bhatt, Amit ;
Abe, Seiichiro ;
Kumaravel, Arthi ;
Vargo, John ;
Saito, Yutaka .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2015, 110 (06) :784-791
[2]   Enhancing proficiency in performing endoscopic submucosal dissection (ESD) by using a prototype robotic endoscope [J].
Chiu, Philip WaiYan ;
Phee, Soo Jay ;
Bhandari, Pradeep ;
Sumiyama, Kazuki ;
Ohya, Tomohiko ;
Wong, Jennie ;
Poon, Carmen C. Y. ;
Tajiri, Hisao ;
Nakajima, Kiyokazu ;
Ho, Khek Yu .
ENDOSCOPY INTERNATIONAL OPEN, 2015, 3 (05) :E439-E442
[3]   Endoluminal surgical triangulation: overcoming challenges of colonic endoscopic submucosal dissections using a novel flexible endoscopic surgical platform: feasibility study in a porcine model [J].
Diana, Michele ;
Chung, Hyunsoo ;
Liu, Keng-Hao ;
Dallemagne, Bernard ;
Demartines, Nicolas ;
Mutter, Didier ;
Marescaux, Jacques .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2013, 27 (11) :4130-4135
[4]   Efficacy and adverse events of EMR and endoscopic submucosal dissection for the treatment of colon neoplasms: a meta-analysis of studies comparing EMR and endoscopic submucosal dissection [J].
Fujiya, Mikihiro ;
Tanaka, Kazuyuki ;
Dokoshi, Tatsuya ;
Tominaga, Motoya ;
Ueno, Nobuhiro ;
Inaba, Yuhei ;
Ito, Takahiro ;
Moriichi, Kentaro ;
Kohgo, Yutaka .
GASTROINTESTINAL ENDOSCOPY, 2015, 81 (03) :583-595
[5]   What we want for ESD is a second hand! Traction method [J].
Fukami, Norio .
GASTROINTESTINAL ENDOSCOPY, 2013, 78 (02) :274-276
[6]   A new endoscopic mucosal resection procedure using an insulation-tipped electrosurgical knife for rectal flat lesions: report of two cases [J].
Gotoda, T ;
Kondo, H ;
Ono, H ;
Saito, Y ;
Yamaguchi, H ;
Saito, D ;
Yokota, T .
GASTROINTESTINAL ENDOSCOPY, 1999, 50 (04) :560-563
[7]   LEARNING CURVE FOR ENDOSCOPIC SUBMUCOSAL DISSECTION OF LARGE COLORECTAL TUMORS [J].
Hotta, Kinichi ;
Oyama, Tsuneo ;
Shinohara, Tomoaki ;
Miyata, Yoshinori ;
Takahashi, Akiko ;
Kitamura, Yoko ;
Tomori, Akihisa .
DIGESTIVE ENDOSCOPY, 2010, 22 (04) :302-306
[8]   Evaluation of a new multitasking platform for endoscopic full-thickness resection [J].
Ikeda, Keiichi ;
Sumiyama, Kazuki ;
Tajiri, Hisao ;
Yasuda, Kazuhiro ;
Kitano, Seigo .
GASTROINTESTINAL ENDOSCOPY, 2011, 73 (01) :117-122
[9]   Endoscopic therapy for early gastric cancer: Standard techniques and recent advances in ESD [J].
Kume, Keiichiro .
WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (21) :6425-6432
[10]   Endoscopic submucosal dissection [J].
Maple, John T. ;
Abu Dayyeh, Barham K. ;
Chauhan, Shailendra S. ;
Hwang, Joo Ha ;
Komanduri, Sri ;
Manfredi, Michael ;
Konda, Vani ;
Murad, Faris M. ;
Siddiqui, Uzma D. ;
Banerjee, Subhas .
GASTROINTESTINAL ENDOSCOPY, 2015, 81 (06) :1311-1325