Near-Infrared Imaging of the Breast Using Omocianine as a Fluorescent Dye Results of a Placebo-Controlled, Clinical, Multicenter Trial

被引:18
|
作者
Poellinger, Alexander [1 ]
Persigehl, Thorsten [2 ]
Mahler, Marianne [3 ]
Bahner, Malte [3 ]
Ponder, Steven L. [4 ]
Diekmann, Felix [1 ]
Bremer, Christoph [2 ,5 ]
Moesta, Thomas [6 ]
机构
[1] Dept Radiol, Berlin, Germany
[2] Univ Hosp Muenster, Dept Clin Radiol, Munster, Germany
[3] Mivenion GmbH, Berlin, Germany
[4] Imaging Diagnost Syst Inc, Ft Lauderdale, FL USA
[5] St Franziskus Hosp GmbH, Dept Clin Radiol, Munster, Germany
[6] Klinikum Reg Hannover, Dept Surg, Hannover, Germany
关键词
optical imaging; diffuse optical tomography; breast cancer; Omocianine; fluorescence imaging; DIFFUSE OPTICAL TOMOGRAPHY; INDOCYANINE GREEN; MAMMOGRAPHY; CANCER; DIAPHANOGRAPHY; EXPERIENCE; DIAGNOSIS; LESIONS; IMAGES; AGENT;
D O I
10.1097/RLI.0b013e318229ff25
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To evaluate the efficacy of the near-infrared (NIR) dye Omocianine in a placebo-controlled, dose-escalating multicenter trial for the detection of malignant breast lesions by using a NIR imaging system. Materials and Methods: The study was approved by the ethical review board of Berlin and Munster,, and all participants provided written informed consent. Fifty-two consecutive patients were examined with NIR imaging before, during, and after intravenous injection of Omocianine. Three-dimensional absorption and fluorescence diffuse optical tomography scans were recorded simultaneously on a prototype NIR imaging unit (Computed Tomography Laser Mammography, Imaging Diagnostic Systems, Inc., Ft. Lauderdale, FL). Two readers assessed the images in consensus and assigned visibility scores to lesions seen on the absorption and absorption-corrected fluorescence diffuse optical tomography mammograms. Imaging results were compared with histopathologic findings. To analyze whether lesion detection rate for malignant lesions depended on the size of the lesion, lesions were dichotomized into those measuring less than 20 mm and those measuring 20 mm or more. Moreover, the shortest diameter between the center of the target lesions and the skin was measured on axial optical mammography data. Results: There were a total of 53 target lesions. Histopathologically, 22 target lesions were diagnosed as benign and 31 target lesions as malignant. In the absorption mode, a detection rate of 11.8% for benign and 44.4% for malignant lesions across all dose groups was found. In the fluorescence mode, a detection rate of 17.6% was revealed for benign and 55.6% for malignant lesions across all dose groups. For dose group 0.1 mg/kg, a detection rate of 100% was found for malignant lesions in the fluorescence mode and 71.4% in the absorption mode. Across all dose groups in the fluorescence mode, detection rate for malignant target lesions in breasts smaller than the median axial breast diameter of 12.8 cm was higher with 69.2% than in median diameters >= 12.8 cm with 46.2%. Omocianine-enhanced fluorescence optical mammography allowed a better detection of more superficially located lesions, with detection rates for a lesion-skin distance < 20 mm of 63.6%, for < 30 mm of 47.4% and for >= 30 mm of 25%. Malignant target lesions with a diameter < 20 mm were slightly better detected with 61.5% in contrast to suspicious lesions < 20 mm with 53.8%. Optimal imaging time points varied strongly among the different target lesions and Omocianine dose groups, with a mean optimal time point for malignant lesions at 188 +/- 385 minutes. Conclusion: Preliminary data suggest that fluorescence imaging after Omocianine administration has the potential to detect malignant breast lesions. As our study showed considerable variations in the detection of breast cancer at different fluorophore concentrations ranging from 20% to 100%, future work needs to be done to assess the suitable dose for NIR imaging.
引用
收藏
页码:697 / 704
页数:8
相关论文
共 50 条
  • [21] Near-infrared fluorescence imaging compared to standard sentinel lymph node detection with blue dye in patients with vulvar cancer - a randomized controlled trial
    Deken, Marion M.
    van Doorn, Helena C.
    Verver, Danielle
    Boogerd, Leonora S. F.
    de Valk, Kim S.
    Rietbergen, Daphne D. D.
    van Poelgeest, Mariette I. E.
    de Kroon, Cor D.
    Beltman, Jogchum J.
    van Leeuwen, Fijs W. B.
    Putter, Hein
    Braak, Jeffrey P. B. M.
    de Geus-Oei, Lioe-Fee
    van de Velde, Cock J. H.
    Burggraaf, Jacobus
    Vahrmeijer, Alexander L.
    Gaarenstroom, Katja N.
    GYNECOLOGIC ONCOLOGY, 2020, 159 (03) : 672 - 680
  • [22] Optical imaging of experimental arthritis using allogeneic leukocytes labeled with a near-infrared fluorescent probe
    Gerhard H. Simon
    Heike E. Daldrup-Link
    Juli Kau
    Stephan Metz
    Juergen Schlegel
    Guido Piontek
    Olaf Saborowski
    Stavros Demos
    Justus Duyster
    Bernd J. Pichler
    European Journal of Nuclear Medicine and Molecular Imaging, 2006, 33
  • [23] The FLARE Intraoperative Near-Infrared Fluorescence Imaging System: A First-in-Human Clinical Trial in Perforator Flap Breast Reconstruction
    Lee, Bernard T.
    Hutteman, Merlijn
    Gioux, Sylvain
    Stockdale, Alan
    Lin, Samuel J.
    Ngo, Long H.
    Frangioni, John V.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2010, 126 (05) : 1472 - 1481
  • [24] Near-infrared fluorescent aza-BODIPY dye-loaded biodegradable polymeric nanoparticles for optical cancer imaging
    Casey L. Hamon
    Christopher L. Dorsey
    Tuğba Özel
    Eugenia M. Barnes
    Todd W. Hudnall
    Tania Betancourt
    Journal of Nanoparticle Research, 2016, 18
  • [25] Laparoscopic cholecystectomy in a swine model using a novel near-infrared fluorescent IV dye (BL-760)
    Cho, Yu Jeong
    Nam, So-Hyun
    Oh, Eugene
    Luciano, Michael P.
    Lee, Choonghee
    Shin, Il Hyung
    Schnermann, Martin J.
    Cha, Jaepyeong
    Kim, Kwan Woo
    LASERS IN SURGERY AND MEDICINE, 2022, 54 (02) : 305 - 310
  • [26] Molecular imaging of human tumor cells that naturally overexpress type 2 cannabinoid receptors using a quinolone-based near-infrared fluorescent probe
    Wu, Zhiyuan
    Shao, Pin
    Zhang, Shaojuan
    Ling, Xiaoxi
    Bai, Mingfeng
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (07)
  • [27] Real-time intraoperative detection of breast cancer using near-infrared fluorescence imaging and Methylene Blue
    Tummers, Q. R. J. G.
    Verbeek, F. P. R.
    Schaafsma, B. E.
    Boonstra, M. C.
    van der Vorst, J. R.
    Liefers, G. -J.
    van de Velde, C. J. H.
    Frangioni, J. V.
    Vahrmeijer, A. L.
    EJSO, 2014, 40 (07): : 850 - 858
  • [28] In vivo near-infrared imaging and phototherapy of tumors using a cathepsin B-activated fluorescent probe
    Chen, Xiaoqiang
    Lee, Dayoung
    Yu, Sungsook
    Kim, Gyoungmi
    Lee, Songyi
    Cho, Yejin
    Jeong, Haengdueng
    Nam, Ki Taek
    Yoon, Juyoung
    BIOMATERIALS, 2017, 122 : 130 - 140
  • [29] Rationale and design of the PRevention of cArdiac Dysfunction during Adjuvant breast cancer therapy (PRADA II) trial: a randomized, placebo-controlled, multicenter trial
    Mecinaj, A.
    Gulati, G.
    Heck, S. L.
    Holte, E.
    Fagerland, M. W.
    Larsen, A., I
    Blix, E. S.
    Geisler, J.
    Wethal, T.
    Omland, T.
    CARDIO-ONCOLOGY, 2021, 7 (01)
  • [30] Rationale and design of the PRevention of cArdiac Dysfunction during Adjuvant breast cancer therapy (PRADA II) trial: a randomized, placebo-controlled, multicenter trial
    A Mecinaj
    G Gulati
    SL Heck
    E Holte
    MW Fagerland
    AI Larsen
    E.S Blix
    J Geisler
    T Wethal
    T Omland
    Cardio-Oncology, 7