Experimental investigation on heating performance of heat pump for electric vehicles at-20 °C ambient temperature

被引:101
作者
Qin, Fei [1 ,2 ,3 ]
Xue, Qingfeng [4 ]
Velez, Giovanny Marcelo Albarracin [5 ]
Zhang, Guiying [1 ,2 ,3 ]
Zou, Huiming [1 ,2 ]
Tian, Changqing [1 ,2 ,5 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Beijing Key Lab Thermal Sci & Technol, Beijing 100190, Peoples R China
[2] Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Cryogen, Beijing 100190, Peoples R China
[3] Univ Chinese Acad Sci, Beijing, Peoples R China
[4] China FAQ Grp Corp R&D Ctr, Changchun, Peoples R China
[5] Catholic Univ Cuenca, Quito, Ecuador
基金
中国国家自然科学基金;
关键词
Air source heat pump; Refrigerant injection; Electric vehicle; Low ambient temperature; Experimental investigation; REFRIGERANT INJECTION; SCROLL COMPRESSOR; COLD REGIONS; SYSTEM; DESIGN;
D O I
10.1016/j.enconman.2015.01.024
中图分类号
O414.1 [热力学];
学科分类号
摘要
Since the performance of conventional air source heat pump (ASHP) for electric vehicles (EVs) is apt to decline sharply in low ambient temperature, it will consume more electricity of the cell, and affect driving mileage in cold regions. Aiming at developing high efficiency heating system for EVs in cold regions, an ASHP system applying refrigerant injection for EVs is designed, as well as the test bench is built to investigate its performance. According to the operation condition of EVs, heating performances are tested on different in-car inlet air temperature and various fresh air ratios under -20 degrees C ambient temperature. The system cycle process with refrigerant injection, as well as the influences of refrigerant injection and dryness are also analyzed and discussed. The results show that the heating capacity of the ASHP with refrigerant injection can be increased up to 31%, and in comparison with the conventional heat pump system its heating performance is better when in-car inlet temperature is above -10 degrees C. Therefore, ASHP with refrigerant injection has great potentiality to be applied for the EVs in cold regions. (c) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:39 / 49
页数:11
相关论文
共 24 条
[1]  
[Anonymous], T ASME J FLUIDS ENG
[2]   Two-stage air-source heat pump for residential heating and cooling applications in northern US climates [J].
Bertsch, Stefan S. ;
Groll, Eckhard A. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (07) :1282-1292
[3]  
Bhatti MS, 1999, ASHRAE J, V41, P51
[4]  
Cao Y., 2009, DEV EV ELECT AIR CON
[5]   Influence of liquid refrigerant injection on the performance of an inverter-driven scroll compressor [J].
Cho, H ;
Chung, JT ;
Kim, Y .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (01) :87-94
[6]   Experimental study of an improved air source heat pump [J].
Ding, YJ ;
Chai, QH ;
Ma, GY ;
Jiang, Y .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (15-16) :2393-2403
[7]  
Direk M, 2011, WORLD REN EN C SWED, P3605
[8]   A techno-economic comparison of ground-coupled and air-coupled heat pump system for space cooling [J].
Esen, Hikmet ;
Inalli, Mustafa ;
Esen, Mehmet .
BUILDING AND ENVIRONMENT, 2007, 42 (05) :1955-1965
[9]   Optimum cycle control of a two-stage injection heat pump with a double expansion sub-cooler [J].
Heo, Jaehyeok ;
Kang, Hoon ;
Kim, Yongchan .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (01) :58-67
[10]   Comparison of the heating performance of air-source heat pumps using various types of refrigerant injection [J].
Heo, Jaehyeok ;
Jeong, Min Woo ;
Baek, Changhyun ;
Kim, Yongchan .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (02) :444-453