On-line metals preconcentration and simultaneous determination using cloud point extraction and inductively coupled plasma optical emission spectrometry in water samples

被引:96
作者
Yamini, Yadollah [1 ]
Faraji, Mohammad [1 ]
Shariati, Shahab [1 ]
Hassani, Rahim [1 ]
Ghambarian, Mahnaz [1 ]
机构
[1] Tarbiat Modares Univ, Dept Chem, Tehran, Iran
关键词
metal ions; on-line cloud point extraction; inductively coupled plasma-optical emission spectrometry; Triton X-114; water samples;
D O I
10.1016/j.aca.2008.02.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new on-line cloud point extraction (CPE) system coupled to ICP-OES was designed for simultaneous extraction, preconcentration and determination of Cd2+, Co2+, Cr3+, Cu2+, Fe3+ and Mn2+ ions in water samples. This is based on the complexation of the metal ions with 1-(2-thenoyl)-3,3,3-trifluoraceton reagent (TTA) at pH 6.0 in the presence of non-ionic surfactant of Triton X-114. The micellar solution was heated above 60 degrees C and loaded through a column packed with cotton, which acts as a filter for retaining the analyte-entrapped surfactant-rich phase. Then the surfactant-rich phase was eluted using propanol:0.5 mol L-1 nitric acid solution (75:25, v/v) at a flow rate of 3.0 mL min(-1) and directly introduced into the nebulizer of the ICP-OES. Several factors influencing the instrumental conditions and extraction were evaluated and optimized. Under the optimum conditions, the enhancement factors of the proposed method for target ions were between 42 and 97, the detection limits (DLs) were in the range of 0.1-2.2 mu g L-1. The relative standard deviations (R.S.D.s) at 100 mu g L-1 concentration levels of each ion were found to be less than 4.6%. Also, the calibration graphs were linear in the range of 0.5-100 mu g L-1 with the correlation coefficients within the range of 0.9948-0.9994. Finally, the developed method was successfully applied to the extraction and determination of the mentioned metal ions in the tap, well, sea and mineral water samples and satisfactory results were obtained. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:144 / 151
页数:8
相关论文
共 43 条
[11]   Coupling cloud point extraction to instrumental detection systems for metal analysis [J].
Fernanda Silva, Maria ;
Soledad Cerutti, Estela ;
Martinez, Luis D. .
MICROCHIMICA ACTA, 2006, 155 (3-4) :349-364
[12]   Cloud-point extraction/preconcentration on-line flow injection method for mercury determination [J].
Garrido, M ;
Di Nezio, MS ;
Lista, AG ;
Palomeque, M ;
Band, BSF .
ANALYTICA CHIMICA ACTA, 2004, 502 (02) :173-177
[13]   Cloud point extraction for the determination of copper, nickel and cobalt ions in environmental samples by flame atomic absorption spectrometry [J].
Ghaedi, M. ;
Shokrollahi, A. ;
Ahmadi, F. ;
Rajabi, H. R. ;
Soylak, M. .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 150 (03) :533-540
[14]   Optimization of a multi-elemental preconcentration procedure for the monitoring survey of dissolved metal species in natural waters [J].
Giokas, DL ;
Paleologos, EK ;
Karayannis, MI .
ANALYTICA CHIMICA ACTA, 2005, 537 (1-2) :249-257
[15]   Determination of rare earth elements in seawater by on-line column preconcentration inductively coupled plasma mass spectrometry [J].
Hirata, S ;
Kajiya, T ;
Aihara, M ;
Honda, K ;
Shikino, O .
TALANTA, 2002, 58 (06) :1185-1194
[16]   On-line preconcentration and simultaneous determination of heavy metal ions by inductively coupled plasma-atomic emission spectrometry [J].
Karami, H ;
Mousavi, MF ;
Yamini, Y ;
Shamsipur, M .
ANALYTICA CHIMICA ACTA, 2004, 509 (01) :89-94
[17]  
KATARZYNA M, 2001, ENVIRON SCI TECHNOL, V35, P2341
[18]   On-line cloud point extraction combined with electrothermal vaporization inductively coupled plasma atomic emission spectrometry for the speciation of inorganic antimony in environmental and biological samples [J].
Li, Yingjie ;
Hu, Bin ;
Jiang, Zucheng .
ANALYTICA CHIMICA ACTA, 2006, 576 (02) :207-214
[19]  
Liang P, 2005, ATOM SPECTROSC, V26, P89
[20]   Cloud point extraction and graphite furnace atomic absorption spectrometry determination of manganese(II) and iron(III) in water samples [J].