Intraday Repeatability of Bruch's Membrane Opening-Based Neuroretinal Rim Measurements

被引:25
作者
Enders, Philip [1 ]
Bremen, Andreas [1 ]
Schaub, Friederike [1 ]
Hermann, Manuel M. [1 ]
Diestelhorst, Michael [1 ]
Dietlein, Thomas [1 ]
Cursiefen, Claus [1 ]
Heindl, Ludwig M. [1 ]
机构
[1] Univ Hosp Cologne, Dept Ophthalmol, Cologne, Germany
关键词
Bruch's membrane opening-based neuroretinal rim measurements; inter-measurement variation analysis; SD-OCT of the optic nerve head; OPTICAL COHERENCE TOMOGRAPHY; INTRAOCULAR-PRESSURE MEASUREMENTS; SCANNING LASER OPHTHALMOSCOPY; FIBER LAYER THICKNESS; DISC MARGIN ANATOMY; NERVE HEAD; GLAUCOMA; POLARIMETRY; POPULATION; PERIMETRY;
D O I
10.1167/iovs.17-22812
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To assess possible intraday variability in Bruch's membrane opening-based (BMO) assessment of neuroretinal rim by spectral-domain optical coherence tomography (SD-OCT) of the optic nerve head (ONH) as well as to evaluate its independence from intraindividual IOP changes. METHODS. In this noninterventional, prospective cohort study, 51 consecutively enrolled patients with glaucoma or ocular hypertension underwent standardized SD-OCT of the ONH and IOP assessment at two different time points with a time gap of 5 hours on the same day. Random effects models, intraclass correlation coefficients (ICC) and Bland-Altman plots were used to analyze repeatability of BMO minimum rim width (BMO-MRW) and area (BMO-MRA) and peripapillary retinal nerve fiber layer (RNFL) thickness measurements. RESULTS. Mean BMO area was 1.86 +/- 0.30 mm(2). At baseline, mean BMO-MRW was 206.46 +/- 0.86 mu m, mean BMO-MRA was 0.89 +/- 0.34 mm(2), and mean RNFL thickness was 71.61 +/- 0.20 mu m. Within intraindividual measurements, mean difference was 2.95 mu m or 1.76% for BMO-MRW, 0.02 mm 2 or 2.68% for BMO-MRA, and 1.18 mu m or 1.89% for RNFL thickness. Comparing time points, eta(2) was 0.001 (P = 0.757) for RNFL thickness, 0.043 (P = 0.01) for BMO-MRA, and 0.07 (P = 0.06) for BMO-MRW. Intraclass correlation coefficients were greater than 0.994, respectively. Variability of morphometric parameters did not correlate to intraindividual IOP fluctuations. CONCLUSIONS. Assessment of BMO-MRW by SD-OCT shows high intraday repeatability, which is comparable to the parameter RNFL thickness. Variability seems not to be driven by typical moderate intraday fluctuations of IOP The two-dimensional parameter BMO-MRA incorporates a fairly higher intraindividual variability.
引用
收藏
页码:5195 / 5200
页数:6
相关论文
共 30 条
[1]   Automated Segmentation of the Cup and Rim from Spectral Domain OCT of the Optic Nerve Head [J].
Abramoff, Michael D. ;
Lee, Kyungmoo ;
Niemeijer, Meindert ;
Alward, Wallace L. M. ;
Greenlee, Emily C. ;
Garvin, Mona K. ;
Sonka, Milan ;
Kwon, Young H. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (12) :5778-5784
[2]   The psychophysics of glaucoma: Improving the structure/function relationship [J].
Anderson, RS .
PROGRESS IN RETINAL AND EYE RESEARCH, 2006, 25 (01) :79-97
[3]   Mapping structural to functional damage in glaucoma with standard automated perimetry and confocal scanning laser ophthalmoscopy [J].
Anton, A ;
Yamagishi, N ;
Zangwill, L ;
Sample, PA ;
Weinreb, RN .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 125 (04) :436-446
[4]   Structure-function relationships using confocal scanning laser ophthalmoscopy, optical coherence tomography, and scanning laser polarimetry [J].
Bowd, Christopher ;
Zangwill, Linda M. ;
Medeiros, Felipe A. ;
Tavares, Ivan M. ;
Hoffmann, Esther M. ;
Bourne, Rupert R. ;
Sample, Pamela A. ;
Weinreb, Robert N. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (07) :2889-2895
[5]  
CAPRIOLI J, 1989, SURV OPHTHALMOL, V33, P319
[6]   Bruch's Membrane Opening Minimum Rim Width and Retinal Nerve Fiber Layer Thickness in a Normal White Population A Multicenter Study [J].
Chauhan, Balwantray C. ;
Danthurebandara, Vishva M. ;
Sharpe, Glen P. ;
Demirel, Shaban ;
Girkin, Christopher A. ;
Mardin, Christian Y. ;
Scheuerle, Alexander F. ;
Burgoyne, Claude F. .
OPHTHALMOLOGY, 2015, 122 (09) :1786-1794
[7]   From Clinical Examination of the Optic Disc to Clinical Assessment of the Optic Nerve Head: A Paradigm Change [J].
Chauhan, Balwantray C. ;
Burgoyne, Claude F. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (02) :218-227
[8]   Enhanced Detection of Open-angle Glaucoma with an Anatomically Accurate Optical Coherence Tomography-Derived Neuroretinal Rim Parameter [J].
Chauhan, Balwantray C. ;
O'Leary, Neil ;
AlMobarak, Faisal A. ;
Reis, Alexandre S. C. ;
Yang, Hongli ;
Sharpe, Glen P. ;
Hutchison, Donna M. ;
Nicolela, Marcelo T. ;
Burgoyne, Claude F. .
OPHTHALMOLOGY, 2013, 120 (03) :535-543
[9]  
Chen Teresa C, 2009, Trans Am Ophthalmol Soc, V107, P254
[10]   The use of Bruch's membrane opening-based optical coherence tomography of the optic nerve head for glaucoma detection in microdiscs [J].
Enders, Philip ;
Schaub, Friederike ;
Adler, Werner ;
Nikoluk, Roman ;
Hermann, Manuel M. ;
Heindl, Ludwig M. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (04) :530-535