PVC membrane based potentiometric sensors for uranium determination

被引:49
|
作者
Hassan, SSM [1 ]
Ali, MM
Attawiya, AMY
机构
[1] Ain Shams Univ, Fac Sci, Dept Chem, Cairo, Egypt
[2] Nucl Mat Author, Cairo, Egypt
关键词
uranyl sensor; PVC membrane; potentiometry; uranium ores; tris(2-ethylhexyl)phosphate; O-(1,2-dihydro-2-oxo-1-pyridyl)-N,N,N ',N '-bis(tetramethylene)uronium hexafluorophosphate;
D O I
10.1016/S0039-9140(01)00385-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two novel uranyl PVC matrix membrane sensors responsive to uranyl ion are described. The first sensor incorporates tris(2-ethylhexyl)phosphate (TEHP) as both electroactive material and plasticizer and sodium tetraphenylborate (NaTPB) as an ion discriminator. The sensor displays a rapid and linear response for UO22+ ions over the concentration range 1 x 10(-1)-2 x 10(-5) mol l(-1) UO22+ with a cationic slope of 25.0 +/- 0.2 mV decade(-1). The working pH range is 2.8-3.6 and the life span is 4 weeks. The second sensor contains O-(1,2-dihydro-2-oxo-1-pyridyl)-N,N,N ' ,N ' -bis(tetra-methylene)uronium hexafluorophosphate (TPTU) as a sensing material, sodium tetraphenylborate as an ion discriminator and dioctyl phenylphosphonate (DOPP) as a plasticizer. Linear and stable response for 1 x 10(-1)-5 x 10(-5) mol l(-1) UO22+ with near-Nernstian slope of 27.5 +/- 0.2 mV decade(-1) are obtained. The working pH range is 2.5-3.5 and the life span of the sensor is 6 weeks. Interference from many inorganic cations is negligible for both sensors. However, interference caused by some ions (e.g. Th4+, Cu2+, Fe3+) is eliminated by a prior ion exchange or solvent extraction step. Direct potentiometric determination of as little as 5 mug ml(-1) uranium in aqueous solutions shows an average recovery of 97.2 +/- 1.3%. Application for the determination of uranium at levels of 0.01-1 wt.% in naturally occurring and certified ores gives results with good correlation with data obtained by X-ray fluorescence. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1153 / 1161
页数:9
相关论文
共 50 条
  • [41] A new PVC-membrane electrode based on a thia-substituted macrocyclic diamide for selective potentiometric determination of silver ion
    Shamsipur, M
    Kazemi, SY
    Niknam, K
    Sharghi, H
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2002, 23 (01) : 53 - 58
  • [42] A PVC Membrane Sensor for Potentiometric Determination of Atorvastatin in Biological Samples and Pharmaceutical Preparations
    Saber, Amr Lotfy
    ELECTROANALYSIS, 2013, 25 (12) : 2707 - 2714
  • [43] PVC membrane sensor based on IO4-CPC ion pair for potentiometric determination of periodate
    Othman, Abdelhameedm M.
    PROGRESS IN ENVIRONMENTAL SCIENCE AND TECHNOLOGY, VOL I, 2007, : 323 - 327
  • [44] Sertraline: Theoretical Studies and a New Potentiometric PVC Membrane Sensor for its Determination
    Saber, Amr L.
    Tuzun, Burak
    Alessa, Hussain
    Althakafy, Jalal T.
    CURRENT ANALYTICAL CHEMISTRY, 2023, 19 (03) : 262 - 271
  • [45] A PVC-based capric acid membrane potentiometric sensor for lead(II) ions
    Mousavi, MF
    Barzegar, MB
    Sahari, S
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 73 (2-3) : 199 - 204
  • [46] MWCNTs Based Carbon Paste and PVC Membrane Potentiometric Electrodes for Monitoring of Bupropion Hydrochloride
    Ganjali, M. R.
    Mizani, F.
    Norouzi, P.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (08): : 7631 - 7642
  • [47] Novel PVC-membrane Potentiometric Sensors based on 2-Amino-N-(2-Mercapto phenyl) Benzamid for Silver Ion
    Mizani, Farhang
    Moradi, Maryam
    Faridbod, Farnoush
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2013, 5 (03): : 352 - 367
  • [48] Potentiometric Membrane Sensors for Determination of Memantine Hydrochloride and Pramipexole Dihydrochloride Monohydrate
    Merey, Hanan A.
    Helmy, Marwa I.
    Tawakkol, Shereen M.
    Toubar, Safaa S.
    Risk, Mohamed S.
    PORTUGALIAE ELECTROCHIMICA ACTA, 2012, 30 (01) : 31 - 43
  • [49] Polymeric Membrane Sensors for Batch and Flow Injection Potentiometric Determination of Procainamide
    Alrabiah, Haitham
    Homoda, Atef M. A.
    Radowan, Abdellatef A.
    Ezzeldin, Essam
    Mostafa, Gamal A. E.
    IEEE SENSORS JOURNAL, 2021, 21 (04) : 4198 - 4208
  • [50] Potentiometric membrane sensor for determination of saccharin
    Elmosallamy, MAF
    Ghoneim, MM
    Killa, HMA
    Saber, AL
    MICROCHIMICA ACTA, 2005, 151 (1-2) : 109 - 113