PVC membrane based potentiometric sensors for uranium determination

被引:49
|
作者
Hassan, SSM [1 ]
Ali, MM
Attawiya, AMY
机构
[1] Ain Shams Univ, Fac Sci, Dept Chem, Cairo, Egypt
[2] Nucl Mat Author, Cairo, Egypt
关键词
uranyl sensor; PVC membrane; potentiometry; uranium ores; tris(2-ethylhexyl)phosphate; O-(1,2-dihydro-2-oxo-1-pyridyl)-N,N,N ',N '-bis(tetramethylene)uronium hexafluorophosphate;
D O I
10.1016/S0039-9140(01)00385-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two novel uranyl PVC matrix membrane sensors responsive to uranyl ion are described. The first sensor incorporates tris(2-ethylhexyl)phosphate (TEHP) as both electroactive material and plasticizer and sodium tetraphenylborate (NaTPB) as an ion discriminator. The sensor displays a rapid and linear response for UO22+ ions over the concentration range 1 x 10(-1)-2 x 10(-5) mol l(-1) UO22+ with a cationic slope of 25.0 +/- 0.2 mV decade(-1). The working pH range is 2.8-3.6 and the life span is 4 weeks. The second sensor contains O-(1,2-dihydro-2-oxo-1-pyridyl)-N,N,N ' ,N ' -bis(tetra-methylene)uronium hexafluorophosphate (TPTU) as a sensing material, sodium tetraphenylborate as an ion discriminator and dioctyl phenylphosphonate (DOPP) as a plasticizer. Linear and stable response for 1 x 10(-1)-5 x 10(-5) mol l(-1) UO22+ with near-Nernstian slope of 27.5 +/- 0.2 mV decade(-1) are obtained. The working pH range is 2.5-3.5 and the life span of the sensor is 6 weeks. Interference from many inorganic cations is negligible for both sensors. However, interference caused by some ions (e.g. Th4+, Cu2+, Fe3+) is eliminated by a prior ion exchange or solvent extraction step. Direct potentiometric determination of as little as 5 mug ml(-1) uranium in aqueous solutions shows an average recovery of 97.2 +/- 1.3%. Application for the determination of uranium at levels of 0.01-1 wt.% in naturally occurring and certified ores gives results with good correlation with data obtained by X-ray fluorescence. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1153 / 1161
页数:9
相关论文
共 50 条
  • [31] Ciprofloxacin Nano-Composite Carbon Paste and PVC Membrane Potentiometric Sensors
    Faridbod, Farnoush
    Poursaberi, Tahereh
    Norouzi, Parviz
    Ganjali, Mohammad Reza
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (04): : 3693 - 3705
  • [32] Automatic potentiometric system for quantification of three imidazole derivatives based on new polymeric PVC membrane sensors
    Ayman H. Kamel
    Amina A. A. Argig
    Ionics, 2017, 23 : 2201 - 2211
  • [33] Automatic potentiometric system for quantification of three imidazole derivatives based on new polymeric PVC membrane sensors
    Kamel, Ayman H.
    Argig, Amina A. A.
    IONICS, 2017, 23 (08) : 2201 - 2211
  • [34] PVC Membrane Potentiometric Sensor Based on a Schiff Base for Determination of Ho3+ ions
    Tamaddon, Atefeh
    Sadeghi, Hayedeh Bagheri
    Mollaei, Somayeh
    Ebrahimi, Arash Afshar
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2014, 6 (06): : 676 - 687
  • [35] PVC-Membrane Potentiometric Sensor for the Determination of Tamoxifen in Pharmaceutical Formulations
    Kanberoglu, Gulsah Saydan
    Coldur, Fatih
    Topcu, Cihan
    Cubuk, Osman
    IEEE SENSORS JOURNAL, 2015, 15 (11) : 6199 - 6207
  • [36] PVC Membrane Sensor Based on Periodate-Cetylpyridinium Ion Pair for the Potentiometric Determination of Periodate
    Othman, Abdelhameed M.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 65 (11) : 1191 - 1197
  • [37] PVC Membrane and Coated Graphite Sensors for the Determination of Vitamin B1
    Faridbod, Farnoush
    Jamshidpour, Tahereh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2016, 8 (03): : 397 - 408
  • [38] Potentiometric membrane sensors for the selective determination of cinnarizine in pharmaceutical preparations
    Hassan, SSM
    AbdelAziz, RM
    Abbas, AB
    ANALYTICA CHIMICA ACTA, 1996, 321 (01) : 47 - 52
  • [39] Development of a Potentiometric Glucose Biosensor Based on a PVC Membrane Electrode
    Kang Pingli
    Ma Xiaoyan
    Lin Mi
    Liu Xinfei
    Wang Jianguo
    ACTA CHIMICA SINICA, 2011, 69 (24) : 3002 - 3006
  • [40] Cetrimide Potentiometric PVC membrane Sensor
    Faridbod, Farnoush
    Khamseh-nejad, Masoumeh
    Ganjali, Mohammad Reza
    Norouzi, Parviz
    Hajiaghababaei, Leila
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (03): : 1917 - 1926