PVC membrane based potentiometric sensors for uranium determination

被引:49
|
作者
Hassan, SSM [1 ]
Ali, MM
Attawiya, AMY
机构
[1] Ain Shams Univ, Fac Sci, Dept Chem, Cairo, Egypt
[2] Nucl Mat Author, Cairo, Egypt
关键词
uranyl sensor; PVC membrane; potentiometry; uranium ores; tris(2-ethylhexyl)phosphate; O-(1,2-dihydro-2-oxo-1-pyridyl)-N,N,N ',N '-bis(tetramethylene)uronium hexafluorophosphate;
D O I
10.1016/S0039-9140(01)00385-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two novel uranyl PVC matrix membrane sensors responsive to uranyl ion are described. The first sensor incorporates tris(2-ethylhexyl)phosphate (TEHP) as both electroactive material and plasticizer and sodium tetraphenylborate (NaTPB) as an ion discriminator. The sensor displays a rapid and linear response for UO22+ ions over the concentration range 1 x 10(-1)-2 x 10(-5) mol l(-1) UO22+ with a cationic slope of 25.0 +/- 0.2 mV decade(-1). The working pH range is 2.8-3.6 and the life span is 4 weeks. The second sensor contains O-(1,2-dihydro-2-oxo-1-pyridyl)-N,N,N ' ,N ' -bis(tetra-methylene)uronium hexafluorophosphate (TPTU) as a sensing material, sodium tetraphenylborate as an ion discriminator and dioctyl phenylphosphonate (DOPP) as a plasticizer. Linear and stable response for 1 x 10(-1)-5 x 10(-5) mol l(-1) UO22+ with near-Nernstian slope of 27.5 +/- 0.2 mV decade(-1) are obtained. The working pH range is 2.5-3.5 and the life span of the sensor is 6 weeks. Interference from many inorganic cations is negligible for both sensors. However, interference caused by some ions (e.g. Th4+, Cu2+, Fe3+) is eliminated by a prior ion exchange or solvent extraction step. Direct potentiometric determination of as little as 5 mug ml(-1) uranium in aqueous solutions shows an average recovery of 97.2 +/- 1.3%. Application for the determination of uranium at levels of 0.01-1 wt.% in naturally occurring and certified ores gives results with good correlation with data obtained by X-ray fluorescence. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1153 / 1161
页数:9
相关论文
共 50 条
  • [21] PVC membrane and coated graphite potentiometric sensors based on 1-phenyl-3-pyridin-2-yl-thiourea for selective determination of iron(III)
    Motlagh, Masoud Ghanei
    Taher, Mohammad Ali
    Ahmadi, Ali
    ELECTROCHIMICA ACTA, 2010, 55 (22) : 6724 - 6730
  • [22] Potentiometric determination of cadmium using coated platinum and PVC membrane sensors based on N,N′-bis(salicylaldehyde)phenylenediamine (salophen)
    Mohammad Mirzaei
    Hadi Behrooj Pili
    Journal of Analytical Chemistry, 2015, 70 : 731 - 737
  • [23] Potentiometric determination of cadmium using coated platinum and PVC membrane sensors based on N,N'-bis(salicylaldehyde)phenylenediamine (salophen)
    Mirzaei, Mohammad
    Pili, Hadi Behrooj
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (06) : 731 - 737
  • [24] Potentiometric PVC membrane ion–selective electrode for the determination of Sr(II) ions
    Özbek O.
    Sensors International, 2022, 3
  • [25] Potentiometric PVC Membrane Sensor for the Determination of Phenylephrine Hydrochloride in Some Pharmaceutical Products
    Giahi, M.
    Mirzaei, M.
    Lahijani, G. Veghar
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2010, 7 (02) : 333 - 338
  • [26] Potentiometric PVC membrane sensor for the determination of phenylephrine hydrochloride in some pharmaceutical products
    M. Giahi
    M. Mirzaei
    G. Veghar Lahijani
    Journal of the Iranian Chemical Society, 2010, 7 : 333 - 338
  • [27] Development of PVC membrane potentiometric sensor for the determination of potassium ion and its applications
    Isildak, Omer
    Ozbek, Oguz
    Gurdere, Meliha Burcu
    Cetin, Alper
    PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, 2021, 27 (07): : 851 - 855
  • [28] PVC Membrane Sensor for Potentiometric Determination of Dicyclomine in Pharmaceutical Formulation
    Faridbod, Farnoush
    Larijani, Bagher
    Ganjali, Mohammad Reza
    Norouzi, Parviz
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (11): : 10404 - 10413
  • [29] PVC membrane sensor based on periodate—Cetylpyridinium ion pair for the potentiometric determination of periodate
    Abdelhameed M. Othman
    Journal of Analytical Chemistry, 2010, 65 : 1191 - 1197
  • [30] Potentiometric Determination of Loperamide Hydrochloride by Loperamide PVC Membrane and Nano-Composite Electrodes
    Faridbod, F.
    Mizani, F.
    Ganjali, M. R.
    Norouzi, P.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (08): : 7643 - 7654