PVC membrane based potentiometric sensors for uranium determination

被引:49
|
作者
Hassan, SSM [1 ]
Ali, MM
Attawiya, AMY
机构
[1] Ain Shams Univ, Fac Sci, Dept Chem, Cairo, Egypt
[2] Nucl Mat Author, Cairo, Egypt
关键词
uranyl sensor; PVC membrane; potentiometry; uranium ores; tris(2-ethylhexyl)phosphate; O-(1,2-dihydro-2-oxo-1-pyridyl)-N,N,N ',N '-bis(tetramethylene)uronium hexafluorophosphate;
D O I
10.1016/S0039-9140(01)00385-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two novel uranyl PVC matrix membrane sensors responsive to uranyl ion are described. The first sensor incorporates tris(2-ethylhexyl)phosphate (TEHP) as both electroactive material and plasticizer and sodium tetraphenylborate (NaTPB) as an ion discriminator. The sensor displays a rapid and linear response for UO22+ ions over the concentration range 1 x 10(-1)-2 x 10(-5) mol l(-1) UO22+ with a cationic slope of 25.0 +/- 0.2 mV decade(-1). The working pH range is 2.8-3.6 and the life span is 4 weeks. The second sensor contains O-(1,2-dihydro-2-oxo-1-pyridyl)-N,N,N ' ,N ' -bis(tetra-methylene)uronium hexafluorophosphate (TPTU) as a sensing material, sodium tetraphenylborate as an ion discriminator and dioctyl phenylphosphonate (DOPP) as a plasticizer. Linear and stable response for 1 x 10(-1)-5 x 10(-5) mol l(-1) UO22+ with near-Nernstian slope of 27.5 +/- 0.2 mV decade(-1) are obtained. The working pH range is 2.5-3.5 and the life span of the sensor is 6 weeks. Interference from many inorganic cations is negligible for both sensors. However, interference caused by some ions (e.g. Th4+, Cu2+, Fe3+) is eliminated by a prior ion exchange or solvent extraction step. Direct potentiometric determination of as little as 5 mug ml(-1) uranium in aqueous solutions shows an average recovery of 97.2 +/- 1.3%. Application for the determination of uranium at levels of 0.01-1 wt.% in naturally occurring and certified ores gives results with good correlation with data obtained by X-ray fluorescence. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1153 / 1161
页数:9
相关论文
共 50 条
  • [1] PVC membrane sensors for potentiometric determination of acebutolol
    Mostafa, Gamal Abdel-Hafiz
    Hefnawy, Mohamed Mahmoud
    Al-Majed, Abdulrahman
    SENSORS, 2007, 7 (12): : 3272 - 3286
  • [2] Clomipramine Determination by Potentiometric PVC Membrane and Carbon Paste Sensors
    Faridbod, Farnoush
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (03): : 315 - 326
  • [3] Ionophore-based potentiometric PVC membrane sensors for the determination of moxifloxacin
    Homoda, Atef M. A.
    EGYPTIAN JOURNAL OF CHEMISTRY, 2024, 67 (06): : 387 - 394
  • [4] PVC MATRIX MEMBRANE SENSORS FOR POTENTIOMETRIC DETERMINATION OF ARECOLINE
    Abounassif, A.
    Al-Hadiya, B. M.
    Mostafa, Gamal A. E.
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2010, 38 (02) : 165 - 177
  • [5] PVC Membrane Sensors for Potentiometric Determination of Bambuterol in Pharmaceutical Formulation
    Ezzeldin, Essam
    Hefnawy, Mohammed M.
    Abounassif, Mohammed A.
    Tammam, Marwa H.
    Mostafa, Gamal A. E.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (11): : 10570 - 10581
  • [6] Ionophore-based potentiometric PVC membrane sensors for determination of phenobarbitone in pharmaceutical formulations
    Alrabiah, Haitham
    Al-Majed, Abdulrahman
    Abounassif, Mohammed
    Mostafa, Gamal A. E.
    ACTA PHARMACEUTICA, 2016, 66 (04) : 503 - 514
  • [7] Pramipexole Symmetric and Asymmetric Potentiometric PVC Membrane Sensors
    Faridbod, Farnoush
    Jamshidpour, Tahereh
    Ganjali, Mohammad Reza
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (09): : 7990 - 8001
  • [8] Potentiometric Determination of Cyclizine by a PVC membrane Sensor
    Ganjali, Mohammad Reza
    Larijani, Bagher
    Faridbod, Farnoush
    Norouzi, Parviz
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (08): : 10487 - 10497
  • [9] Potentiometric determination of moxifloxacin in some pharmaceutical formulation using PVC membrane sensors
    Mohammed M Hefnawy
    Atef M Homoda
    Mohammed A Abounassif
    Amer M Alanazi
    Abdulrahaman Al-Majed
    Gamal A Mostafa
    Chemistry Central Journal, 8
  • [10] Potentiometric determination of moxifloxacin in some pharmaceutical formulation using PVC membrane sensors
    Hefnawy, Mohammed M.
    Homoda, Atef M.
    Abounassif, Mohammed A.
    Alanazi, Amer M.
    Al-Majed, Abdulrahaman
    Mostafa, Gamal A.
    CHEMISTRY CENTRAL JOURNAL, 2014, 8