Single- versus multi-detector row CT of the brain: Quality assessment

被引:34
作者
Jones, TR [1 ]
Kaplan, RT [1 ]
Lane, B [1 ]
Atlas, SW [1 ]
Rubin, GD [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
关键词
brain; CT; computed tomography (CT); artifact; comparative studies; technology;
D O I
10.1148/radiology.219.3.r01jn47750
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the quality of brain computed tomographic (CT) studies obtained with a four-channel multi-detector row CT scanner compared with those obtained with a single-detector row CT scanner. MATERIALS AND METHODS: Forty-seven patients referred for brain CT were imaged with both single- and multi-detector row scanners. Single-detector row CT Ii-rages were acquired by using a 5-mm-collimated beam in the transverse mode. Multi-detector row CT images were acquired in four simultaneous 2.5-mm-thick sections, which were combined in projection space to create two contiguous 5-mm-thick sections. Two neuroradiologists blinded to the acquisition technique independently evaluated the CT image pairs, which were presented in a stacked mode on two adjacent monitors. Each study was graded by using a five-point scale for posterior fossa artifact, overall image quality, and overall preference. RESULTS: Multi-detector row CT studies were acquired 1.8 times faster than single-detector row CT studies (0.92 vs 0.52 section per second). Multi-detector row CT posterior fossa artifact was less than single-detector row CT posterior fossa artifact in 87 (93%) of 94 studies. Overall preference was expressed for multidetector row CT in 84 (89%) of 94 studies. The differences in mean posterior fossa artifact scores (P < .001) and mean overall image quality scores (P = .001) were significant. CONCLUSION: Brain CT image obtained with multi-detector row CT resulted in -significantly less posterior fossa artifact and were preferred to single-detector row CT images.
引用
收藏
页码:750 / 755
页数:6
相关论文
共 10 条
[1]   COMPUTERIZED TRANSVERSE AXIAL SCANNING (TOMOGRAPHY) .2. CLINICAL APPLICATION [J].
AMBROSE, J .
BRITISH JOURNAL OF RADIOLOGY, 1973, 46 (552) :1023-1047
[2]   Stair-step artifacts with single versus multiple detector-row helical CT [J].
Fleischmann, D ;
Rubin, GD ;
Paik, DS ;
Yen, SY ;
Hilfiker, PR ;
Beaulieu, CF ;
Napel, S .
RADIOLOGY, 2000, 216 (01) :185-196
[3]   NON-LINEAR PARTIAL VOLUME ARTIFACTS IN X-RAY COMPUTED-TOMOGRAPHY [J].
GLOVER, GH ;
PELC, NJ .
MEDICAL PHYSICS, 1980, 7 (03) :238-248
[4]   Four multidetector-row helical CT: Image quality and volume coverage speed [J].
Hu, H ;
He, HD ;
Foley, WD ;
Fox, SH .
RADIOLOGY, 2000, 215 (01) :55-62
[5]   METHOD FOR CORRECTING BONE INDUCED ARTIFACTS IN COMPUTED TOMOGRAPHY SCANNERS [J].
JOSEPH, PM ;
SPITAL, RD .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1978, 2 (01) :100-108
[6]  
LEVY JM, 1991, AM J NEURORADIOL, V12, P686
[7]   ARTIFACTS IN COMPUTED-TOMOGRAPHY OF THE POSTERIOR-FOSSA - A COMPARATIVE PHANTOM STUDY [J].
MOSTROM, U ;
YTTERBERGH, C .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (04) :560-566
[8]   CRANIAL CT ARTIFACTS AND GANTRY ANGULATION [J].
ROZEIK, C ;
KOTTERER, O ;
PREISS, J ;
SCHUTZ, M ;
DINGLER, W ;
DEININGER, HK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (03) :381-386
[9]  
Rubin GD, 1999, J COMPUT ASSIST TOMO, V23, pS83
[10]   Aorta and iliac arteries: Single versus multiple detector-row helical CT angiography [J].
Rubin, GD ;
Shiau, MC ;
Leung, AN ;
Kee, ST ;
Logan, LJ ;
Sofilos, MC .
RADIOLOGY, 2000, 215 (03) :670-676