Numerical Investigation of Pipelines Modeling in Small-Scale Concentrated Solar Combined Heat and Power Plants

被引:10
作者
Tascioni, Roberto [1 ,2 ]
Cioccolanti, Luca [2 ]
Del Zotto, Luca [2 ]
Habib, Emanuele [1 ]
机构
[1] Sapienza Univ Roma, DIAEE, I-00184 Rome, Italy
[2] Univ Telemat eCampus, CREAT, I-22060 Novedrate, Italy
关键词
numerical analysis; renewable energy; dynamic simulation; concentrated solar power plant; organic Rankine cycle system; thermal losses; SIMULATION; PERFORMANCE; NETWORK;
D O I
10.3390/en13020429
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper four different detailed models of pipelines are proposed and compared to assess the thermal losses in small-scale concentrated solar combined heat and power plants. Indeed, previous numerical analyses carried out by some of the authors have revealed the high impact of pipelines on the performance of these plants because of their thermal inertia. Hence, in this work the proposed models are firstly compared to each other for varying temperature increase and mass flow rate. Such comparison shows that the one-dimensional (1D) longitudinal model is in good agreement with the results of the more detailed two-dimensional (2D) model at any temperature gradient for heat transfer fluid velocities higher than 0.1 m/s whilst the lumped model agrees only at velocities higher than 1 m/s. Then, the 1D longitudinal model is implemented in a quasi-steady-state Simulink model of an innovative microscale concentrated solar combined heat and power plant and its performances evaluated. Compared to the results obtained using the Simscape library model of the tube, the performances of the plant show appreciable discrepancies during the winter season. Indeed, whenever the longitudinal thermal gradient of the fluid inside the pipeline is high (as at part-load conditions in winter season), the lumped model becomes inaccurate with more than 20% of deviation of the thermal losses and 30% of the organic Rankine cycle (ORC) electric energy output with respect to the 1D longitudinal model. Therefore, the analysis proves that an hybrid model able to switch from a 1D longitudinal model to a zero-dimensional (0D) model with delay based on the fluid flow rate is recommended to obtain results accurate enough whilst limiting the computational efforts.
引用
收藏
页数:16
相关论文
共 19 条
[1]  
[Anonymous], RIG COND FLUID FLOW
[2]  
[Anonymous], 2001, THESIS
[3]   Thermal Transients in District Heating Systems [J].
Chertkov, Michael ;
Novitsky, Nikolai N. .
ENERGY, 2019, 184 :22-33
[4]   Mathematical modelling of operation modes and performance evaluation of an innovative small-scale concentrated solar organic Rankine cycle plant [J].
Cioccolanti, Luca ;
Tascioni, Roberto ;
Arteconi, Alessia .
APPLIED ENERGY, 2018, 221 :464-476
[5]   Models for fast modelling of district heating and cooling networks [J].
del Hoyo Arce, Itzal ;
Herrero Lopez, Saioa ;
Lopez Perez, Susana ;
Rama, Miika ;
Klobut, Krzysztof ;
Febres, Jesus A. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 82 :1863-1873
[6]   Heat transmission over long pipes: New model for fast and accurate district heating simulations [J].
Denarie, A. ;
Aprile, M. ;
Motta, M. .
ENERGY, 2019, 166 :267-276
[7]  
European Commission, 2018, Clean energy for all Europeans
[8]  
Frank P.Incropera David P. DeWitt., 1990, FUNDAMENTALS HEAT MA, Vthird
[9]  
Mahkamov K, 2018, PROCEEDINGS OF THE ASME POWER CONFERENCE, 2018, VOL 1
[10]   Modelling and simulation of phase change material latent heat storages applied to a solar-powered Organic Rankine Cycle [J].
Manfrida, Giampaolo ;
Secchi, Riccardo ;
Stanczyk, Kamil .
APPLIED ENERGY, 2016, 179 :378-388