Measurement and numerical simulation of single-sided mechanical ventilation in broiler houses

被引:25
作者
Bustamante, Eliseo [1 ,2 ]
Calvet, Salvador [1 ]
Estelles, Fernando [1 ]
Torres, Antonio G. [1 ]
Hospitaler, Antonio [2 ]
机构
[1] Univ Politecn Valencia, Inst Anim Sci & Technol, Camino Vera S-N, E-46022 Valencia, Spain
[2] Univ Politecn Valencia, Dept Construct Engn & Civil Engn Projects, Camino Vera S-N, E-46022 Valencia, Spain
关键词
Broiler farm; Computational Fluid Dynamics (CFD); Livestock buildings; Mechanical ventilation; Sensors; Single-sided; COMPUTATIONAL FLUID-DYNAMICS; AIR VELOCITY; NATURAL VENTILATION; POULTRY BUILDINGS; FLOW; SYSTEM; TEMPERATURE; CFD; PERFORMANCE; PREDICTION;
D O I
10.1016/j.biosystemseng.2017.05.009
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
In recent years, some broiler production farms especially in Mediterranean areas, have incorporated single-sided mechanical ventilation (i.e. air inlets and fans are located in the same lateral wall). However, little scientific information on the performance of mechanical single-sided ventilation systems is available to date. This ventilation method is fitted to broiler houses because this ventilation system appears appropriate to diminish the stress and mortality of broilers during hot seasons in this climate. To analyse the single-sided ventilation method scientifically, the indoor environments of broiler houses were examined by numerical simulation using computational fluid dynamics (CFD) with validation using a range of different buildings with direct measurements using a multi-sensor system. An analysis of variation of the results of the validation tests produced to a p-value of 0.3908. Thus, the methodology employed (i.e. CFD or sensors) was not significant. The CFD simulations showed a wide range of values for air velocity: the minimum value of air velocity at broiler level was 0.52 +/- 0.40 m s(-1) and the maximum was 1.29 +/- 0.41 m s(-1). Two major conclusions were drawn in terms indoor air velocity: (i) excessive heterogeneity in the plane where the animals were located; and (ii) insufficient air movement to contribute to the thermoregulation of the birds and lower their internal heat and associated thermal stress in occasional periods of hot weather. (C) 2017 IAgrE. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:55 / 68
页数:14
相关论文
共 30 条
  • [1] Design analysis of single-sided natural ventilation
    Allocca, C
    Chen, QY
    Glicksman, LR
    [J]. ENERGY AND BUILDINGS, 2003, 35 (08) : 785 - 795
  • [2] [Anonymous], 2009, GAMB US GUID VERS 2
  • [3] [Anonymous], 2001, ASHRAE FUNDAMENTALS
  • [4] [Anonymous], 2009, FLUENT US GUID
  • [5] [Anonymous], 1980, Numerical heat transfer and fluid flow
  • [6] Analysis of airflow through experimental rural buildings: Sensitivity to turbulence models
    Bartzanas, T.
    Kittas, C.
    Sapounas, A. A.
    Nikita-Martzopoulou, Ch.
    [J]. BIOSYSTEMS ENGINEERING, 2007, 97 (02) : 229 - 239
  • [7] Modeling of air inlets in CFD prediction of airflow in ventilated animal houses
    Bjerg, B
    Svidt, K
    Zhang, G
    Morsing, S
    Johnsen, JO
    [J]. COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2002, 34 (1-3) : 223 - 235
  • [8] Application of computational fluid dynamics to the prediction of airflow in a mechanically ventilated commercial poultry building
    Blanes-Vidal, V.
    Guijarro, E.
    Balasch, S.
    Torres, A. G.
    [J]. BIOSYSTEMS ENGINEERING, 2008, 100 (01) : 105 - 116
  • [9] Development and field test of an on-line computerized instrumentation system for air velocity, temperature and differential pressure measurements in poultry houses
    Blanes-Vidal, V.
    Guijarro, E.
    Nadimi, E. S.
    Torres, A. G.
    [J]. SPANISH JOURNAL OF AGRICULTURAL RESEARCH, 2010, 8 (03) : 570 - 579