Degradation of buckling capacity of slender concrete-filled double skin steel tubular columns due to interface compliance

被引:1
作者
Cas, Bojan [1 ]
Schnabl, Simon [1 ,2 ]
机构
[1] Univ Ljubljana, Fac Civil & Geodet Engn, Jamova 2, Ljubljana 1000, Slovenia
[2] Univ Ljubljana, Fac Chem & Chem Technol, Vecna Pot 113, Ljubljana 1000, Slovenia
基金
奥地利科学基金会;
关键词
buckling; CFDST; column; contact; double-skin; HIGH STRENGTH CONCRETE; CHS OUTER; NONLINEAR-ANALYSIS; INTERLAYER SLIP; STUB COLUMNS; BEHAVIOR; INNER; TUBES; BEAM; TESTS;
D O I
10.12989/sem.2022.82.5.643
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper a novel mathematical model and its analytical solution of global buckling behaviour of slender elastic concrete-filled double-skin tubular (CFDST) columns with finite compliance between the steel tubes and a sandwiched concrete core is derived for the first time. The model is capable of investigating the influence of various basic parameters on critical buckling loads of CFDST columns. It is shown that the elastic buckling load of circular and slender CFDST columns is independent on longitudinal contact stiffness, but, on the other hand, it can be considerably dependent on circumferential contact stiffness. The increasing of the circumferential contact stiffness increases the critical buckling load. Furthermore, it is shown that analytical results can agree well with the experimental and numerical results if the calibrated values of circumferential contact stiffness are used in the calculations. Moreover, it is shown that the contact between the steel tubes and a sandwiched concrete core of tested large-scale CFDST columns used in the comparison is relatively weak. Finally, the proposed analytical results can be used as a benchmark solution.
引用
收藏
页码:643 / 650
页数:8
相关论文
共 42 条
[1]  
AISC, 2010, Load and Resistance Factor Design Specification for Structural Steel Buildings
[2]   Column tests of dodecagonal section double skin concrete-filled steel tubes [J].
Chen, Ju ;
Ni, Ying-Ying ;
Jin, Wei-Iiang .
THIN-WALLED STRUCTURES, 2015, 88 :28-40
[3]   Tests on concrete filled double-skin (CHS outer and SHS inner) composite short columns under axial compression [J].
Elchalakani, M ;
Zhao, XL ;
Grzebieta, R .
THIN-WALLED STRUCTURES, 2002, 40 (05) :415-441
[4]  
EN, 1992, 199411 EN
[5]   Performance of concrete-filled double-skin circular tubes in compression [J].
Essopjee, Y. ;
Dundu, M. .
COMPOSITE STRUCTURES, 2015, 133 :1276-1283
[6]   Concrete-filled double skin (SHS outer and CHS inner) steel tubular beam-columns [J].
Han, LH ;
Tao, Z ;
Huang, H ;
Zhao, XL .
THIN-WALLED STRUCTURES, 2004, 42 (09) :1329-1355
[7]   Behaviour and design of square concrete-filled double skin tubular columns with inner circular tubes [J].
Hassanein, M. F. ;
Kharoob, O. F. ;
Gardner, L. .
ENGINEERING STRUCTURES, 2015, 100 :410-424
[8]   Analysis of circular concrete-filled double skin tubular slender columns with external stainless steel tubes [J].
Hassanein, M. F. ;
Kharoob, O. F. .
THIN-WALLED STRUCTURES, 2014, 79 :23-37
[9]   Compressive strength of circular concrete-filled double skin tubular short columns [J].
Hassanein, M. F. ;
Kharoob, O. F. .
THIN-WALLED STRUCTURES, 2014, 77 :165-173
[10]   Circular concrete-filled double skin tubular short columns with external stainless steel tubes under axial compression [J].
Hassanein, M. F. ;
Kharoob, O. F. ;
Liang, Q. Q. .
THIN-WALLED STRUCTURES, 2013, 73 :252-263