Developing and using fast shear wave elastography to quantify physiologically-relevant tendon forces

被引:17
作者
Ahmadzadeh, S. M. Hassan [1 ]
Chen, Xiao [1 ,2 ]
Hagemann, Henrik [1 ]
Tang, Meng-Xing [1 ]
Bull, Anthony M. J. [1 ]
机构
[1] Imperial Coll London, Dept Bioengn, London SW7 2AZ, England
[2] Nanjing Univ Informat Sci & Technol, Sch Elect & Informat Engn, Nanjing, Peoples R China
关键词
Shear wave elastography; Tendon forces; Shear wave speed; Tensile testing; Musculoskeletal models' validation; ULTRASOUND ELASTOGRAPHY; MECHANICAL-PROPERTIES; BIOMECHANICAL PROPERTIES; QUANTITATIVE ASSESSMENT; TENSILE PROPERTIES; ELASTIC PROPERTIES; SPATIAL VARIATIONS; ACHILLES TENDONS; HUMAN-SKIN; MUSCLE;
D O I
10.1016/j.medengphy.2019.04.005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Direct quantification of physiologically-relevant tendon forces can be used in a wide range of clinical applications. However, tendon forces have usually been estimated either indirectly by computational models or invasively using force transducers, and direct non-invasive measurement of forces remains a big challenge. The aim of this study was to investigate the feasibility of using Shear Wave Elastography (SWE) for quantifying human tendon forces at physiological levels. An experimental protocol was developed to measure Shear Wave Speed (SWS) and tensile force in a human patellar tendon using SWE and conventional tensile testing to quantify the correlation between SWS and load. The SWE system was customised to allow imaging of fast shear waves expected in human tendons under physiological loading which is outside the normal range of the existing SWE systems. SWS increased from 10.8 m/s to 36.1 m/s with the increasing tensile load from 8N to 935N and a strong linear correlation between SWS and load (r =0.99, p < 0.01) was observed. The findings in this study suggest that SWE can be used as a potential non-invasive method for direct quantification of physiologically-relevant tendon forces, as well as for validating the estimated forces from other methods such as computational models. (C) 2019 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:116 / 122
页数:7
相关论文
共 71 条
[1]   FORCE ANALYSIS OF THE PATELLAR MECHANISM [J].
AHMED, AM ;
BURKE, DL ;
HYDER, A .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1987, 5 (01) :69-85
[2]  
[Anonymous], 2011, ULTRASOUND MED BIOL
[3]   Viscoelasticity in Achilles Tendonopathy: Quantitative Assessment by Using Real-time Shear-Wave Elastography [J].
Aubry, Sebastien ;
Nueffer, Jean-Philippe ;
Tanter, Mickael ;
Becce, Fabio ;
Vidal, Chrystelle ;
Michel, Fabrice .
RADIOLOGY, 2015, 274 (03) :821-829
[4]   Biomechanical properties of the calcaneal tendon in vivo assessed by transient shear wave elastography [J].
Aubry, Sebastien ;
Risson, Jean-Romain ;
Kastler, Adrian ;
Barbier-Brion, Benoit ;
Siliman, Gaye ;
Runge, Michel ;
Kastler, Bruno .
SKELETAL RADIOLOGY, 2013, 42 (08) :1143-1150
[5]   Shear Wave Ultrasound Elastography of the Prostate Initial Results [J].
Barr, Richard G. ;
Memo, Richard ;
Schaub, Carl R. .
ULTRASOUND QUARTERLY, 2012, 28 (01) :13-20
[6]   Supersonic shear imaging: A new technique for soft tissue elasticity mapping [J].
Bercoff, J ;
Tanter, M ;
Fink, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (04) :396-409
[7]   Strain-rate sensitivity of the lateral collateral ligament of the knee [J].
Bonner, Timothy J. ;
Newell, Nicolas ;
Karunaratne, Angelo ;
Pullen, Andy D. ;
Amis, Andrew A. ;
Bull, Anthony M. J. ;
Masouros, Spyros D. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2015, 41 :261-270
[8]   Estimation of Individual Muscle Force Using Elastography [J].
Bouillard, Killian ;
Nordez, Antoine ;
Hug, Francois .
PLOS ONE, 2011, 6 (12)
[9]   Ultrasound Elastography: The New Frontier in Direct Measurement of Muscle Stiffness [J].
Brandenburg, Joline E. ;
Eby, Sarah F. ;
Song, Pengfei ;
Zhao, Heng ;
Brault, Jeffrey S. ;
Chen, Shigao ;
An, Kai-Nan .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2014, 95 (11) :2207-2219
[10]   In vivo evaluation of the elastic anisotropy of the human Achilles tendon using shear wave dispersion analysis [J].
Brum, J. ;
Bernal, M. ;
Gennisson, J. L. ;
Tanter, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03) :505-523