Immediate Migration of Biopsy Clip Markers After Upright Digital Breast Tomosynthesis-Guided Vacuum-Assisted Core Biopsy

被引:10
|
作者
Teichgraeber, Davis C. [1 ]
Martaindale, Sarah [1 ]
Omofoye, Toma S. [1 ]
Hess, Kenneth R. [2 ]
Parikh, Jay R. [1 ]
Whitman, Gary J. [1 ]
机构
[1] Univ Texas MD Anderson Canc, Dept Diagnost Radiol, Div Diagnost Imaging, 1515 Holcombe Blvd,Unit 1350, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc, Dept Biostat, Houston, TX USA
关键词
Digital breast tomosynthesis; image-guided biopsy; clip placement; clip migration; breast imaging; prone stereotactic vacuum-assisted biopsy; digital breast tomosynthesis-guided vacuum-assisted biopsy; localization; DEPLOYMENT; PLACEMENT; PITFALLS;
D O I
10.1016/j.acra.2019.03.022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: The goal of this retrospective study was to evaluate the rate of immediate post-biopsy clip migration on an upright digital tomosynthesis-guided vacuum-assisted core biopsy unit and determine if any factors were associated with immediate clip migration. Materials and Methods: We performed a retrospective review of patients who had undergone a biopsy performed at one facility from November 1, 2014 to September 30, 2016. Post-biopsy mammograms were reviewed to assess immediate clip position relative to the targeted lesion. The effects of age, lesion type, breast density, biopsy approach, number of samples, size of the biopsy chamber, and clip type on clip migration were examined using logistic regression analysis. Results: One hundred ninety-seven biopsies were performed on 188 patients for calcifications (n = 159), architectural distortions (n = 29), masses (n = 5), and asymmetries (n = 4). The clip migration rate was 38% as defined as greater than 0.5 cm from the site of the biopsied lesion. The only independently predictive variable of clip migration was breast density in a numeric covariate in the logistic regression model, as migration was more likely with decreased breast density. The estimated odds ratio for a single level increase in BI-RADS breast density was 0.60 (95% confidence interval: 0.40, 0.91) with p = 0.018. Conclusion: Immediate clip migration following biopsy was more likely with decreased breast density. Radiologists should be aware of immediate clip migration as correct clip location guides preoperative localization and allows the biopsy site to be monitored for changes on future mammograms.
引用
收藏
页码:204 / 209
页数:6
相关论文
共 50 条
  • [1] Tomosynthesis-guided vacuum-assisted breast biopsy: A feasibility study
    Waldherr, Christian
    Berclaz, Gilles
    Altermatt, Hans Jorg
    Cerny, Peter
    Keller, Patrik
    Dietz, Uwe
    Buser, Katharina
    Ciriolo, Michele
    Sonnenschein, Martin Josef
    EUROPEAN RADIOLOGY, 2016, 26 (06) : 1582 - 1589
  • [2] Tomosynthesis-guided vacuum-assisted breast biopsy: A feasibility study
    Christian Waldherr
    Gilles Berclaz
    Hans Jörg Altermatt
    Peter Cerny
    Patrik Keller
    Uwe Dietz
    Katharina Buser
    Michele Ciriolo
    Martin Josef Sonnenschein
    European Radiology, 2016, 26 : 1582 - 1589
  • [3] Implementation of Upright Digital Breast Tomosynthesis-guided Stereotactic Biopsy
    Omofoye, Toma S.
    Martaindale, Sarah
    Teichgraeber, Davis C.
    Parikh, Jay R.
    ACADEMIC RADIOLOGY, 2017, 24 (11) : 1451 - 1455
  • [4] Prone Versus Upright Digital Tomosynthesis-Guided Biopsy
    Choudhery, Sadia
    Johnson, Matthew
    Fazzio, Robert T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (03) : 760 - 764
  • [5] Clinical performance of digital breast tomosynthesis-guided vacuum-assisted biopsy: a single-institution experience in Japan
    Ido, Mirai
    Saito, Masayuki
    Banno, Hirona
    Ito, Yukie
    Goto, Manami
    Ando, Takahito
    Kousaka, Junko
    Mouri, Yukako
    Fujii, Kimihito
    Imai, Tsuneo
    Nakano, Shogo
    Suzuki, Kojiro
    Murotani, Kenta
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [6] Tomosynthesis-Guided Vacuum-Assisted Breast Biopsy of Architectural Distortion Without a Sonographic Correlate: A Retrospective Review
    Ambinder, Emily B.
    Plotkin, Amy
    Euhus, David
    Mullen, Lisa A.
    Oluyemi, Eniola
    Di Carlo, Philip
    Philip, Mary
    Panigrahi, Babita
    Cimino-Mathews, Ashley
    Myers, Kelly S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2021, 217 (04) : 845 - 854
  • [7] Clip migration after stereotactic vacuum-assisted breast biopsy with the patient in the decubitus position
    Wang, Jane
    Chien, Ning
    Lee, Hsiao-Tung
    EUROPEAN RADIOLOGY, 2020, 30 (11) : 6080 - 6088
  • [8] Upright Tomosynthesis-guided Breast Biopsy: Tips, Tricks, and Troubleshooting
    Vijapura, Charmi A.
    Wahab, Rifat A.
    Thakore, Atharva G.
    Mahoney, Mary C.
    RADIOGRAPHICS, 2021, 41 (05) : 1265 - 1282
  • [9] Clinical performance of digital breast tomosynthesis–guided vacuum-assisted biopsy: a single-institution experience in Japan
    Mirai Ido
    Masayuki Saito
    Hirona Banno
    Yukie Ito
    Manami Goto
    Takahito Ando
    Junko Kousaka
    Yukako Mouri
    Kimihito Fujii
    Tsuneo Imai
    Shogo Nakano
    Kojiro Suzuki
    Kenta Murotani
    BMC Medical Imaging, 23
  • [10] Guiding vacuum-assisted biopsy in prone position: digital breast tomosynthesis vs stereotactic
    Scaperrotta, Gianfranco P.
    Boffelli, Giulia
    Depretto, Catherine
    Di Leo, Giovanni
    Liguori, Alessandro
    Monaco, Cristian Giuseppe
    Anna, Borelli
    Ferranti, Claudio
    TUMORI JOURNAL, 2022, 108 (04): : 326 - 330