Effects of ultrasound on maternal-fetal bonding: a comparison of two- and three-dimensional imaging

被引:62
作者
Ji, EK
Pretorius, DH
Newton, R
Uyan, K
Hull, AD
Hollenbach, K
Nelson, TR
机构
[1] Univ Calif San Diego, Dept Radiol, La Jolla, CA 92037 USA
[2] Univ Calif San Diego, Dept Reprod Med, La Jolla, CA 92037 USA
[3] Univ Calif San Diego, Dept Family & Prevent Med, La Jolla, CA 92037 USA
[4] St Vincent de Paul Village, San Diego, CA USA
[5] Pochon CHA Univ, CHA Gen Hosp, Dept Radiol, Seoul, South Korea
关键词
fetus; maternal-fetal bonding; three-dimensional; ultrasonography;
D O I
10.1002/uog.1896
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives The purpose of this study was to evaluate the effect of two-dimensional (2DUS) compared to three-dimensional ultrasound (3 DUS) imaging on the maternal-fetal bonding process. Methods Fifty mothers who bad 2DUS and 50 who bad 2DUS and 3DUS were included in the study. A postpartum survey by telephone interview was carried out to assess maternal-fetal bonding. Bonding was evaluated by analysis of extent of prenatal image sharing, maternal ability to form a mental picture of the baby, and mother's comments about their ultrasound images. Data were analyzed using the independent t-test, Chi-square and Mann - Whitney U-tests. Results Mothers who received 3DUS showed their ultrasound images to more people (median, 27.5; interquartile range, 14.5-40.0) than mothers receiving 2DUS alone (median, 11.0; interquartile range, 5.0-25.5) (P < 0.001, Z = -3.539). Eighty-two percent of the subjects screened with 3DUS bad a greater tendency to form a mental Picture of the baby postexamination compared to 39% of the 2DUS subjects (P < 0.001, Z = -3.614). Mothers receiving a 3DUS study, were more likely to receive comments on the similarities/differences of the neonate compared to those having 2DUS studies. Furthermore, 70% of the mothers receiving 3DUS felt they 'knew' the baby immediately after birth vs. 56% of the mothers receiving 2DUS (P = 0.009, Z = -2.613). Both 2DUS and 3DUS experiences were positive, however, the comments made by the mothers undergoing 3DUS (n = 18) were more exclamatory (amazed, wonderful, fabulous) than those undergoing 2DUS (n = 4). Patients having a 3DUS examination consistently scored higher than those having a 2DUS examination alone for all categories of maternal-fetal bonding. Conclusion 3DUS appears to more positively, influence the perceptions of mothers to their babies postbirth compared to 2DUS. Specifically, mothers who had 3D US showed their ultrasound images to a greater number of people compared to mothers who had 2DUS alone and this may represent mother's social support system. 3DUS may have a greater impact on the maternal-fetal bonding process. Copyright (c) 2005 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:473 / 477
页数:5
相关论文
共 50 条
[31]   Three-dimensional fetal MR imaging: Will it fulfill its promise? [J].
Levine, D .
RADIOLOGY, 2001, 219 (02) :313-315
[32]   Maternal-fetal attachment in blind women using physical model from three-dimensional ultrasound and magnetic resonance scan data: six serious cases [J].
Werner, Heron ;
Lopes, Jorge ;
Tonni, Gabriele ;
Araujo Junior, Edward .
JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2016, 29 (14) :2229-2232
[33]   Comparison of two- and three-dimensional sonography for the prediction of the extrathyroidal extension of papillary thyroid carcinomas [J].
Yi, Yang Seon ;
Kim, Sang Soo ;
Kim, Won Jin ;
Bae, Min Jung ;
Kang, Ji Hyun ;
Choi, Bo Gwang ;
Jeon, Yun Kyung ;
Kim, Bo Hyun ;
Lee, Byung Joo ;
Wang, Soo Geun ;
Kim, In Joo ;
Kim, Yong Ki .
KOREAN JOURNAL OF INTERNAL MEDICINE, 2016, 31 (02) :313-322
[34]   Comparison of Two- and Three-dimensional Ultrasonography in the Evaluation of Lesion Level in Fetuses with Spina Bifida [J].
Rosa Requeijo, Marcio Jose ;
Bunduki, Victor ;
Vieira Francisco, Rossana Pulcineli ;
Borges Lopes, Marco Antonio ;
Ruano, Rodrigo ;
Zugaib, Marcelo .
REVISTA BRASILEIRA DE GINECOLOGIA E OBSTETRICIA, 2016, 38 (03) :120-126
[35]   Comparison of Two- and Three-Dimensional Methods for Analysis of Trunk Kinematic Variables in the Golf Swing [J].
Smith, Aimee C. ;
Roberts, Jonathan R. ;
Wallace, Eric S. ;
Kong, Pui ;
Forrester, Stephanie E. .
JOURNAL OF APPLIED BIOMECHANICS, 2016, 32 (01) :23-31
[36]   Comparison between Two- and Three-Dimensional Ultrasound in Visualization of Corpus Callosum during Second Trimester Routine Scan: Our Experience [J].
Muscatello, A. ;
Accurti, V. ;
Conte, V. ;
Franchi, V. ;
Colagrande, I. ;
Carta, A. ;
Patacchiola, F. ;
Palermo, P. ;
Carta, G. .
FETAL DIAGNOSIS AND THERAPY, 2013, 33 (03) :201-202
[37]   Biometry of the fetal corpus callosum by three-dimensional ultrasound [J].
Pashaj, S. ;
Merz, E. ;
Wellek, S. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2013, 42 (06) :691-698
[38]   Three-dimensional ultrasound imaging of the equine fetus [J].
Kotoyori, Y. ;
Yokoo, N. ;
Ito, K. ;
Murase, H. ;
Sato, F. ;
Korosue, K. ;
Nambo, Y. .
THERIOGENOLOGY, 2012, 77 (07) :1480-1486
[39]   A three-dimensional ultrasound prostate imaging system [J].
Tong, S ;
Downey, DB ;
Cardinal, HN ;
Fenster, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (06) :735-746
[40]   Fetal thigh volumetry by three-dimensional ultrasound: comparison between multiplanar and VOCAL™ techniques [J].
Beninni, J. R. ;
Faro, C. ;
Marussi, E. F. ;
Barini, R. ;
Peralta, C. F. A. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 35 (04) :417-425