Surfactant-enhanced spectrofluorimetric determination of total aflatoxins from wheat samples after magnetic solid-phase extraction using modified Fe3O4 nanoparticles

被引:27
作者
Manafi, Mohammad Hanif [1 ]
Allahyari, Mehdi [2 ]
Pourghazi, Kamyar [3 ]
Amoli-Diva, Mitra [4 ]
Taherimaslak, Zohreh [5 ]
机构
[1] Marjaan Khatam Co, Training Res & QC Lab, Tehran, Iran
[2] ARA Qual Res Co, Qual Control Lab, Tehran, Iran
[3] Kharazmi Tarbiat Moallem Univ, Fac Chem, Tehran, Iran
[4] PNU, Dept Chem, Tehran, Iran
[5] Bu Ali Sina Univ, Fac Chem, Hamadan, Iran
关键词
Total aflatoxins; Magnetic solid phase extraction; Fe3O4; nanoparticles; Triton X-100; Surfactant-enhanced spectrofluorimetry; PERFORMANCE LIQUID-CHROMATOGRAPHY; SPICE PREPARATIONS; OCHRATOXIN; B-1; MYCOTOXINS; B1; B2;
D O I
10.1016/j.saa.2015.03.050
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The extraction and preconcentration of total aflatoxins (including aflatoxin B-1, B-2, G(1), and G(2)) using magnetic nanoparticles based solid phase extraction (MSPE) followed by surfactant-enhanced spectrofluorimetric detection was proposed. Ethylene glycol bis-mercaptoacetate modified silica coated Fe3O4 nanoparticles as an efficient antibody-free adsorbent was successfully applied to extract aflatoxins from wheat samples. High surface area and strong magnetization properties of magnetic nanoparticles were utilized to achieve high enrichment factor (97), and satisfactory recoveries (92-105%) using only 100 mg of the adsorbent. Furthermore, the fast separation time (less than 10 min) avoids many time-consuming cartridge loading or column-passing procedures accompany with the conventional SPE. In determination step, signal enhancement was performed by formation of Triton X-100 micelles around the analytes in 15% (v/v) acetonitrile-water which dramatically increase the sensitivity of the method. Main factors affecting the extraction efficiency and signal enhancement of the analytes including pH of sample solution, desorption conditions, extraction time, sample volume, adsorbent amount, surfactant concentration and volume and time of micelle formation were evaluated and optimized. Under the optimum conditions, wide linear range of 0.1-50 ng mL(-1) with low detection limit of 0.03 ng mL(-1) were obtained. The developed method was successfully applied to the extraction and preconcentration of aflatoxins in three commercially available wheat samples and the results were compared with the official AOAC method. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:43 / 49
页数:7
相关论文
共 33 条
[1]   Modification and validation for the procedure of immunoaffinity column and HPLC method for the determination of aflatoxin B1 in tobacco [J].
Abdel-Wahhab, M. A. ;
Ibrahim, M. I. M. ;
Abo-Elhawa, T. A. ;
Naguib, K. M. .
TOXICOLOGY LETTERS, 2011, 205 :S292-S292
[2]   High through-put aflatoxin determination in plant material by automated solid-phase extraction on-line coupled to laser-induced fluorescence screening and determination by liquid chromatography-triple quadrupole mass spectrometry [J].
Alcaide-Molina, M. ;
Ruiz-Jimenez, J. ;
Mata-Granados, J. M. ;
Luque de Castro, M. D. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (07) :1115-1125
[3]   Determination and chemometric evaluation of total aflatoxin, aflatoxin B1, ochratoxin A and heavy metals content in corn flours from Turkey [J].
Algul, Isil ;
Kara, Derya .
FOOD CHEMISTRY, 2014, 157 :70-76
[4]  
[Anonymous], 1993, IARC Monographs on the Evaluation of Carcino- genic Risks to Humans. Some Naturally Occurring Substances: Food Items and Constituents, Heterocyclic Aromatic, Amines and Mycotoxins
[5]   Mixed supramolecular hemimicelles aggregates and magnetic carrier technology for solid phase extraction of ibuprofen in environmental samples prior to its HPLC-UV determination [J].
Beiraghi, Asadollah ;
Pourghazi, Kamyar ;
Amoli-Diva, Mitra .
CHEMICAL ENGINEERING SCIENCE, 2014, 108 :103-110
[6]   Magnetic solid phase extraction of mefenamic acid from biological samples based on the formation of mixed hemimicelle aggregates on Fe3O4 nanoparticles prior to its HPLC-UV detection [J].
Beiraghi, Asadollah ;
Pourghazi, Kamyar ;
Amoli-Diva, Mitra ;
Razmara, Akbar .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 945 :46-52
[7]   Mycotoxins [J].
Bennett, JW ;
Klich, M .
CLINICAL MICROBIOLOGY REVIEWS, 2003, 16 (03) :497-+
[8]   Preparation and adsorption properties of monodisperse chitosan-bound Fe3O4 magnetic nanoparticles for removal of Cu(II) ions [J].
Chang, YC ;
Chen, DH .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2005, 283 (02) :446-451
[9]   Simultaneous non-instrumental detection of aflatoxin B1 and ochratoxin A using a clean-up tandem immunoassay column [J].
Goryacheva, Irina Yu. ;
De Saeger, Sarah ;
Delmulle, Barbara ;
Lobeau, Marieke ;
Eremin, Sergei A. ;
Barna-Vetro, Ildiko ;
Van Peteghem, Carlos .
ANALYTICA CHIMICA ACTA, 2007, 590 (01) :118-124
[10]   Determination of aflatoxins B1 and B2 by adsorptive cathodic stripping voltammetry in groundnut [J].
Hajian, R. ;
Ensafi, A. A. .
FOOD CHEMISTRY, 2009, 115 (03) :1034-1037