Quadriceps strength impairment in the mid- to long-term follow-up period after total knee arthroplasty

被引:16
作者
Ishii, Yoshinori [1 ]
Noguchi, Hideo [1 ]
Sato, Junko [1 ]
Sakurai, Tetsuya [1 ]
Toyabe, Shin-ichi [2 ]
机构
[1] Ishii Orthopaed & Rehabil Clin, 1089 Shimo Oshi, Saitama 3610037, Japan
[2] Niigata Univ, Grad Sch Med & Dent Sci, Div Informat Sci & Biostat, 1 Asahimachi Dori Niigata, Niigata 9518520, Japan
关键词
Quadriceps strength; A hand-held dynamometer; PCL-retaining TKA; PCL-substituting TKA; Long-term follow-up; PATIENT SATISFACTION; MUSCLE STRENGTH; ACTIVATION; OUTCOMES; ADULTS; FORCE; TIME; GAIT; TKA;
D O I
10.1007/s00167-016-4333-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Quadriceps strength impairment after total knee arthroplasty (TKA) continues to be a concern. However, most studies of quadriceps strength have short-term follow-up periods. Whether quadriceps strength impairment occurs in the long-term follow-up period after TKA remains unclear. The purpose of this study was to compare the quadriceps strength between posterior cruciate ligament-retaining (CR) and substituting (PS) design mobile-bearing TKA (1) in the same patients after an average of 10 years and (2) between TKA patients and age-matched controls. A prospective, quasi-randomized design was used. Thirty-four patients (68 knees) who underwent bilateral TKA (CR on one side and PS on the other) were followed for a minimum of 5 years, and 35 age-matched controls (70 knees) were evaluated. A handheld dynamometer was used to measure quadriceps isometric strength. For each patient, the maximum value of three trials was used. The ratio of muscle strength to body weight (MS/BW ratio; N/kg) was used to evaluate outcomes. The median MS/BW ratio was 3.3 (range 1.4-10.5) for CR 3.4 (range 0.9-9.3) for PS, and 4.6 (range 0.4-8.8) for controls. The MS/BW ratio did not differ between prosthesis designs, but was significantly smaller in both CR (p = 0.020) and PS (p = 0.024) than in controls. Posterior cruciate ligament-retaining TKA does not confer a substantial advantage an average of 10 years postoperatively. In addition, quadriceps strength, as measured using a hand-held dynamometer, was significantly lower in both TKA patient groups than in age-matched controls. Clinically, the results of this study indicate that quadriceps-strengthening exercises should be continued in the long term after TKA. II.
引用
收藏
页码:3372 / 3377
页数:6
相关论文
共 28 条
[1]  
Alicea J, 2001, Surgery of the Knee, V2, P1507
[2]  
BERMAN AT, 1991, CLIN ORTHOP RELAT R, P106
[3]   Improvement of voluntary quadriceps muscle activation after total knee arthroplasty [J].
Berth, A ;
Urbach, D ;
Awiszus, F .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (10) :1432-1436
[4]   Strength and voluntary activation of quadriceps femoris muscle in total knee arthroplasty with midvastus and subvastus approaches [J].
Berth, Alexander ;
Urbach, Dietmar ;
Neumann, Wolfram ;
Awiszus, Friedemann .
JOURNAL OF ARTHROPLASTY, 2007, 22 (01) :83-88
[5]   A comparison of isokinetic strength testing and gait analysis in patients with posterior cruciate-retaining and substituting knee arthroplasties [J].
Bolanos, AA ;
Colizza, WA ;
McCann, PD ;
Gotlin, RS ;
Wootten, ME ;
Kahn, BA ;
Insall, JN .
JOURNAL OF ARTHROPLASTY, 1998, 13 (08) :906-915
[6]   Patient satisfaction after total knee arthroplasty - A comparison between subjective and objective outcome assessments [J].
Bullens, PHJ ;
van Loon, CJM ;
Malefijt, MCD ;
Laan, RFJM ;
Veth, RPH .
JOURNAL OF ARTHROPLASTY, 2001, 16 (06) :740-747
[7]   Quadriceps strength affects patient satisfaction after total knee arthroplasty [J].
Furu, Moritoshi ;
Ito, Hiromu ;
Nishikawa, Toru ;
Nankaku, Manabu ;
Kuriyama, Shinichi ;
Ishikawa, Masahiro ;
Nakamura, Shinichiro ;
Azukizawa, Masayuki ;
Hamamoto, Yosuke ;
Matsuda, Shuichi .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2016, 21 (01) :38-43
[8]   Comparison of muscle strength of posterior cruciate-restained versus cruciate-sacrificed total knee arthroplasty [J].
Huang, CH ;
Lee, YM ;
Liau, JJ ;
Cheng, CK .
JOURNAL OF ARTHROPLASTY, 1998, 13 (07) :779-783
[9]   Prediction of range of motion 2 years after mobile-bearing total knee arthroplasty: PCL-retaining versus PCL-sacrificing [J].
Ishii, Yoshinori ;
Noguchi, Hideo ;
Takeda, Mitsuhiro ;
Sato, Junko ;
Toyabe, Shin-ichi .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (12) :2002-2008
[10]   Hand-held dynamometry: Reliability of lower extremity muscle testing in healthy, physically active, young adults [J].
Kelln, Brent M. ;
McKeon, Patrick O. ;
Gontkof, Lauren M. ;
Hertel, Jay .
JOURNAL OF SPORT REHABILITATION, 2008, 17 (02) :160-170