Spatial aspects of ventricular repolarization in postinfarction patients

被引:21
作者
Dilaveris, P
Gialafos, E
Pantazis, A
Synetos, A
Triposkiadis, F
Stamatelopoulos, S
Gialafos, J
机构
[1] Hippokrat Hosp, State Dept Cardiol, Athens, Greece
[2] Univ Athens, Sch Med, Alexandras Hosp, Dept Med Therapeut, GR-11527 Athens, Greece
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2001年 / 24卷 / 02期
关键词
spatial QRS-T angle; spatial T amplitude; QT dispersion; repolarization; myocardial infarction;
D O I
10.1046/j.1460-9592.2001.00157.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
QT dispersion has been proposed to reflect the heterogeneity of ventricular repolarization, but a poor reproducibility limits its clinical usefulness. Spatial vectorcardiographic descriptors constitute a novel approach to quantify ventricular repolarization. To test the ability of vectorcardiographic descriptors to discriminate among different subsets of postinfarction patients, 50 consecutively recruited patients with acute MI, 50 patients with history of an old (> 6 months) MI and 50 healthy controls were evaluated. The maxim um and minim um QT and JT intervals and QT and JT dispersion were manually measured from a digitally recorded 12-lead EGG. X, Y, and Z leads were reconstructed from the 12-lead EGG. The amplitude of the maximum spatial T vector (spatial T amplitude), the angle between the maximum spatial QRS and T vectors (spatial QRS-T angle), and the frontal plane QRS-T angle were automatically calculated The spatial T amplitude and the spatial QRS-T angle did nor differ between patients with a recent and those with an old MI (P = 1). QT dispersion was significantly lower in patients with an old MI than in patients with a recent one (P = 0.002). The spatial repolarization descriptors showed better short-term reproducibility than the dispersion indices. In conclusion, the spatial T amplitude and the spatial QRS-T angle are accurate measures of ventricular repolarization that do not differ between patients with recent and those with old MI. The different QT dispersion values observed in this study between the two post-MI groups should be considered cautiously because of the low accuracy of the manual measurements.
引用
收藏
页码:157 / 165
页数:9
相关论文
共 29 条
  • [1] CHOU TC, 1985, CLIN VECTORCARDIOGRA, P243
  • [2] COOKSEY JD, 1977, CLIN VECTORCARDIOGRA
  • [3] CORRECTED ORTHOGONAL ELECTROCARDIOGRAM + VECTORCARDIOGRAM IN 510 NORMAL MEN ( FRANK LEAD SYSTEM )
    DRAPER, HW
    LITTMANN, D
    PEFFER, CJ
    STALLMANN, FW
    PIPBERGER, HV
    [J]. CIRCULATION, 1964, 30 (06) : 853 - &
  • [4] VECTORCARDIOGRAM SYNTHESIZED FROM A 12-LEAD ECG - SUPERIORITY OF THE INVERSE DOWER MATRIX
    EDENBRANDT, L
    PAHLM, O
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 1988, 21 (04) : 361 - 367
  • [5] ELECTROCARDIOGRAPHIC AND VECTORCARDIOGRAPHIC DIAGNOSIS OF POSTERIOR WALL MYOCARDIAL-INFARCTION - SIGNIFICANCE OF THE T-WAVE
    EISENSTEIN, I
    SANMARCO, ME
    MADRID, WL
    SELVESTER, RH
    [J]. CHEST, 1985, 88 (03) : 409 - 416
  • [6] Dynamics of QT dispersion during myocardial infarction and ischaemia
    Glancy, JM
    Garratt, CJ
    deBono, DP
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 1996, 57 (01) : 55 - 60
  • [7] NONUNIFORM RECOVERY OF EXCITABILITY IN VENTRICULAR MUSCLE
    HAN, J
    MOE, GK
    [J]. CIRCULATION RESEARCH, 1964, 14 (01) : 44 - &
  • [8] HIGHAM PD, 1995, BRIT HEART J, V73, P32
  • [9] HIGH RELIABILITY RATES OF SPATIAL PATTERN-ANALYSIS BY VECTORCARDIOGRAM IN ASSESSING SEVERITY OF ECCENTRIC LEFT-VENTRICULAR HYPERTROPHY
    ISHIZAWA, K
    ISHIZAWA, K
    MOTOMURA, M
    KONISHI, T
    WAKABAYASHI, A
    ISHIKAWA, K
    NOHARA, Y
    KAWAI, C
    KOIE, H
    [J]. AMERICAN HEART JOURNAL, 1976, 91 (01) : 50 - 57
  • [10] SHORT-TERM AND LONG-TERM REPRODUCIBILITY OF QT, QTC, AND QT DISPERSION MEASUREMENT IN HEALTHY-SUBJECTS
    KAUTZNER, J
    YI, G
    CAMM, AJ
    MALIK, M
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (05): : 928 - 937