Multileaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segments

被引:239
|
作者
Xia, P [1 ]
Verhey, LJ [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
关键词
intensity modulation; multileaf collimators; conformal therapy;
D O I
10.1118/1.598315
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The "stop and shoot" method of producing intensity modulation using combinations of static multileaf collimator (MLC) segments has a number of advantages including precise dose delivery, easy verification, and general availability. However, due to the potential limitation of prolonged treatment time, it is essential to keep the number of required segments to a reasonable number. We propose an algorithm to minimize the number of segments for an intensity modulated field. In this algorithm, the sequence of delivery intensity is proposed to be a series of powers of 2, depending on the maximum intensity level in the matrix. The MLC leaf position sequence is designed directly on the two-dimensional intensity matrix to irradiate the largest possible area in each segment. The algorithm can be applied directly to MLC systems with different motion constraints. This algorithm has been evaluated by generating 1000 random 15 x 15 cm intensity matrices, each having from 3 to 16 intensity levels. Five clinical intensity modulated fields generated from the NOMOS CORVUS planning system for a complex clinical head and neck case were also tested with this and two other algorithms. The results of both the statistical and clinical studies showed that for all the intensity matrices tested, the proposed algorithm results in the smallest number of segments with a moderately increased monitor units. Thus it is well-suited for use in static MLC intensity modulation beam delivery. For MLC systems with interleaf motion constraint, we prove mathematically that this constraint reduces the tongue and groove effect at the expense of an increase of 25% in the number of segments. (C) 1998 American Association of Physicists in Medicine.
引用
收藏
页码:1424 / 1434
页数:11
相关论文
共 21 条
  • [1] Minimizing the number of segments in a delivery sequence for intensity-modulated radiation therapy with a multileaf collimator
    Dai, JR
    Zhu, YP
    MEDICAL PHYSICS, 2001, 28 (10) : 2113 - 2120
  • [2] Field margin reduction using intensity-modulated x-ray beams formed with a multileaf collimator
    Dirkx, MLP
    Heijmen, BJM
    Korevaar, GA
    vanOs, MJH
    Stroom, JC
    Koper, PCM
    Levendag, PC
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (05): : 1123 - 1129
  • [3] The optimum intensities for multiple static multileaf collimator field compensation
    Evans, PM
    Hansen, VN
    Swindell, W
    MEDICAL PHYSICS, 1997, 24 (07) : 1147 - 1156
  • [4] Improving the resolution of dynamic intensity modulated radiation therapy delivery by reducing the multileaf collimator sampling distance
    Greer, PB
    Beckham, WA
    Ansbacher, W
    Mann, RK
    MEDICAL PHYSICS, 2003, 30 (10) : 2793 - 2803
  • [5] Evaluation of dose calculation algorithm of the peacock system for multileaf intensity modulation collimator
    Wu, A
    Johnson, M
    Chen, ASJ
    Kalnicki, S
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (05): : 1225 - 1231
  • [6] Effect of multileaf collimator leaf width on physical dose distributions in the treatment of CNS and head and neck neoplasms with intensity modulated radiation therapy
    Fiveash, JB
    Murshed, H
    Duan, J
    Hyatt, M
    Caranto, J
    Bonner, JA
    Popple, RA
    MEDICAL PHYSICS, 2002, 29 (06) : 1116 - 1119
  • [7] Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode
    LoSasso, T
    Chui, CS
    Ling, CC
    MEDICAL PHYSICS, 2001, 28 (11) : 2209 - 2219
  • [8] Development and commissioning of a multileaf collimator model in Monte Carlo dose calculations for intensity-modulated radiation therapy
    Jang, SY
    Vassiliev, ON
    Liu, HH
    Mohan, R
    Siebers, JV
    MEDICAL PHYSICS, 2006, 33 (03) : 770 - 781
  • [9] Dosimetric comparison of different multileaf collimator leaves in treatment planning of intensity-modulated radiotherapy for cervical cancer
    Wang, Shichao
    Ai, Ping
    Xie, Li
    Xu, Qingfeng
    Bai, Sen
    Lu, You
    Li, Ping
    Chen, Nianyong
    MEDICAL DOSIMETRY, 2013, 38 (04) : 454 - 459
  • [10] Clinical delivery of intensity modulated conformal radiotherapy for relapsed or second-primary head and neck cancer using a multileaf collimator with dynamic control
    De Neve, W
    De Gersem, W
    Derycke, S
    De Meerleer, G
    Moerman, M
    Bate, MT
    Van Duyse, B
    Vakaet, L
    De Deene, Y
    Mersseman, B
    De Wagter, C
    RADIOTHERAPY AND ONCOLOGY, 1999, 50 (03) : 301 - 314