Pediatric 99mTc-MDP Bone SPECT with Ordered Subset Expectation Maximization Iterative Reconstruction with Isotropic 3D Resolution Recovery

被引:35
作者
Stansfield, Eryn Caamano [3 ]
Sheehy, Niall [3 ]
Zurakowski, David [4 ]
Vija, A. Hans
Fahey, Frederic H. [1 ,2 ]
Treves, S. Ted [1 ,2 ]
机构
[1] Harvard Univ, Sch Med, Childrens Hosp Boston, Dept Radiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Childrens Hosp Boston, Div Nucl Med & Mol Imaging, Boston, MA 02115 USA
[3] Harvard Univ, Sch Med, Joint Program Nucl Med, Boston, MA 02115 USA
[4] Harvard Univ, Sch Med, Childrens Hosp Boston, Dept Anesthesiol, Boston, MA 02115 USA
关键词
EMISSION COMPUTED-TOMOGRAPHY; LOW-BACK-PAIN; EXTERNAL ELECTRICAL-STIMULATION; FILTERED BACKPROJECTION; PARS INTERARTICULARIS; RADIATION RISKS; SPONDYLOLYSIS; SPONDYLOLISTHESIS; CT; ATHLETE;
D O I
10.1148/radiol.10100102
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To perform a preliminary evaluation of the image quality of pediatric technetium 99m (Tc-99m) methylene diphosphonate (MDP) bone single photon emission computed tomography (SPECT) by using iterative reconstruction-ordered subset expectation maximization with three-dimensional resolution recovery (OSEM-3D)-and to assess whether any improvements with use of this technique could lead to a reduction in patient dose or a shortening in imaging time. Materials and Methods: Institutional advisory board approval was obtained for this investigation. Fifty Tc-99m-MDP SPECT studies of the spine were evaluated (36 female and 14 male patients; mean age, 15.5 years). Each study was acquired by using a dual-detector camera, with each detector rotating 360 degrees. By using filtered back projection (FBP) and OSEM-3D, images were reconstructed from data generated by both detectors. Likewise, OSEM-3D was used to reconstruct data from a single detector simulating half the administered radiopharmaceutical activity. Two nuclear medicine physicians, blinded to the patient data, reviewed the images for image quality in four different categories by using a four-point scale: artifacts (category 1), lesions (category 2), noise (category 3), and image sharpness (category 4). Results: Compared with FBP, images reconstructed by using OSEM-3D with one or two detectors showed significant improvement in image quality with regard to lesion detection, noise level, and image sharpness (P < .02, .01, and .001, respectively). With OSEM-3D, no significant differences were observed when either one or two detectors were used. Conclusion: Improved image quality of skeletal SPECT with either a 50% reduction in radiation dose or a 50% reduction in acquisition time or combination of the two can be achieved by using OSEM-3D. (C)RSNA, 2010
引用
收藏
页码:793 / 801
页数:9
相关论文
共 44 条
[1]   Quantitative assessment with SPECT imaging of stress injuries of the pars interarticularis and response to bracing [J].
Anderson, K ;
Sarwark, JF ;
Conway, JJ ;
Logue, ES ;
Schafer, MF .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2000, 20 (01) :28-33
[2]   LOW-BACK-PAIN IN ADOLESCENT ATHLETES - DETECTION OF STRESS INJURY TO THE PARS INTERARTICULARIS WITH SPECT [J].
BELLAH, RD ;
SUMMERVILLE, DA ;
TREVES, ST ;
MICHELI, LJ .
RADIOLOGY, 1991, 180 (02) :509-512
[3]  
Blocklet DC, 1999, J NUCL MED, V40, p303P
[4]   Characterization of ordered-subsets expectation maximization with 3D post-reconstruction Gauss filtering and comparison with filtered backprojection in 99mTc SPECT [J].
Brambilla, M ;
Cannillo, B ;
Dominietto, M ;
Leva, L ;
Secco, C ;
Inglese, E .
ANNALS OF NUCLEAR MEDICINE, 2005, 19 (02) :75-82
[5]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[6]   CLINICAL HIGH-RESOLUTION SKELETAL SINGLE-PHOTON EMISSION TOMOGRAPHY USING A TRIPLE-HEADED GAMMA-CAMERA [J].
BUSCOMBE, JR ;
TOWNSEND, CE ;
KOURIS, K ;
CLARKE, G ;
MAHMOOD, S ;
JARRITT, PH ;
ELL, PJ .
BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (789) :817-822
[7]   Juvenile spondylolysis: a comparative analysis of CT, SPECT and MRI [J].
Campbell, RSD ;
Grainger, AJ ;
Hide, IG ;
Papastefanou, S ;
Greenough, CG .
SKELETAL RADIOLOGY, 2005, 34 (02) :63-73
[8]   PAINFUL SPONDYLOLYSIS OR SPONDYLOLISTHESIS STUDIED BY RADIOGRAPHY AND SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY [J].
COLLIER, BD ;
JOHNSON, RP ;
CARRERA, GF ;
MEYER, GA ;
SCHWAB, JP ;
FLATLEY, TJ ;
ISITMAN, AT ;
HELLMAN, RS ;
ZIELONKA, JS ;
KNOBEL, J .
RADIOLOGY, 1985, 154 (01) :207-211
[9]  
Conover WJ, 1999, Practical nonparametric statistics
[10]  
d'Hemecourt PA, 2002, ORTHOPEDICS, V25, P653