Simultaneous determination of 3-hydroxypropionic acid, methylmalonic acid and methylcitric acid in dried blood spots: Second-tier LC-MS/MS assay for newborn screening of propionic acidemia, methylmalonic acidemias and combined remethylation disorders

被引:52
作者
Monostori, Peter [1 ]
Klinke, Glynis [1 ]
Richter, Sylvia [1 ]
Barath, Akos [2 ]
Fingerhut, Ralph [3 ]
Baumgartner, Matthias R. [3 ]
Koelker, Stefan [1 ]
Hoffmann, Georg F. [1 ]
Gramer, Gwendolyn [1 ]
Okun, Juergen G. [1 ]
机构
[1] Univ Hosp Heidelberg, Div Neuropediat & Metab Med, Dept Gen Pediat, Ctr Pediat & Adolescent Med, Heidelberg, Germany
[2] Univ Szeged, Dept Pediat, Szeged, Hungary
[3] Univ Childrens Hosp Zurich, Childrens Res Ctr, Div Metab, Zurich, Switzerland
关键词
TANDEM MASS-SPECTROMETRY; FALSE-POSITIVE RATE; VITAMIN-B-12; DEFICIENCY; ELECTROSPRAY-IONIZATION; 2-METHYLCITRIC ACID; TOTAL HOMOCYSTEINE; LIQUID-CHROMATOGRAPHY; PHENOTYPIC SPECTRUM; ORGANIC ACIDURIAS; INBORN-ERRORS;
D O I
10.1371/journal.pone.0184897
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background and aims Increased propionylcarnitine levels in newborn screening are indicative for a group of potentially severe disorders including propionic acidemia (PA), methylmalonic acidemias and combined remethylation disorders (MMACBL). This alteration is relatively non-specific, resulting in the necessity of confirmation and differential diagnosis in subsequent tests. Thus, we aimed to develop a multiplex approach for concurrent determination of 3-hydroxypropionic acid, methylmalonic acid and methylcitric acid from the same dried blood spot (DBS) as in primary screening (second-tier test). We also set out to validate the method using newborn and follow-up samples of patients with confirmed PA or MMACBL. Methods The assay was developed using liquid chromatography-tandem mass spectrometry and clinically validated with retrospective analysis of DBS samples from PA or MMACBL patients. Results Reliable determination of all three analytes in DBSs was achieved following simple and fast (< 20 min) sample preparation without laborious derivatization or any additional pipetting steps. The method clearly distinguished the pathological and normal samples and differentiated between PA and MMACBL in all stored newborn specimens. Methylcitric acid was elevated in all PA samples; 3-hydroxypropionic acid was also high in most cases. Methylmalonic acid was increased in all MMACBL specimens; mostly together with methylcitric acid. Conclusions A liquid chromatography-tandem mass spectrometry assay allowing simultaneous determination of the biomarkers 3-hydroxypropionic acid, methylmalonic acid and methylcitric acid in DBSs has been developed. The assay can use the same specimen as in primary screening (second-tier test) which may reduce the need for repeated blood sampling. The presented preliminary findings suggest that this method can reliably differentiate patients with PA and MMACBL in newborn screening. The validated assay is being evaluated prospectively in a pilot project for extension of the German newborn screening panel ("Newborn screening 2020"; Newborn Screening Center, University Hospital Heidelberg).
引用
收藏
页数:16
相关论文
共 39 条
[1]   Quantification of 2-methylcitric acid in dried blood spots improves newborn screening for propionic and methylmalonic acidemias [J].
Al-Dirbashi, Osama Y. ;
McIntosh, Nathan ;
Chakraborty, Pranesh .
JOURNAL OF MEDICAL SCREENING, 2017, 24 (02) :58-61
[2]  
Al-Dirbashi OY, 2014, JIMD REP, V16, P65, DOI 10.1007/8904_2014_321
[3]   Proposed guidelines for the diagnosis and management of methylmalonic and propionic acidemia [J].
Baumgartner, Matthias R. ;
Hoerster, Friederike ;
Dionisi-Vici, Carlo ;
Haliloglu, Goknur ;
Karall, Daniela ;
Chapman, Kimberly A. ;
Huemer, Martina ;
Hochuli, Michel ;
Assoun, Murielle ;
Ballhausen, Diana ;
Burlina, Alberto ;
Fowler, Brian ;
Gruenert, Sarah C. ;
Gruenewald, Stephanie ;
Honzik, Tomas ;
Merinero, Begona ;
Perez-Cerda, Celia ;
Scholl-Buergi, Sabine ;
Skovby, Flemming ;
Wijburg, Frits ;
MacDonald, Anita ;
Martinelli, Diego ;
Sass, Joern Oliver ;
Valayannopoulos, Vassili ;
Chakrapani, Anupam .
ORPHANET JOURNAL OF RARE DISEASES, 2014, 9
[4]   Suitability of methylmalonic acid and total homocysteine analysis in dried bloodspots [J].
de Sain-van der Velden, Monique G. M. ;
van der Ham, Maria ;
Jans, Judith J. ;
Visser, Gepke ;
van Hasselt, Peter M. ;
Prinsen, Hubertus C. M. T. ;
Verhoeven-Duif, Nanda M. .
ANALYTICA CHIMICA ACTA, 2015, 853 :435-441
[5]   Expanded newborn screening: social and ethical issues [J].
Dhondt, Jean-Louis .
JOURNAL OF INHERITED METABOLIC DISEASE, 2010, 33 :S211-S217
[6]   National Academy of Clinical Biochemistry Laboratory Medicine Practice Guidelines: Follow-Up Testing for Metabolic Disease Identified by Expanded Newborn Screening Using Tandem Mass Spectrometry; Executive Summary [J].
Dietzen, Dennis J. ;
Rinaldo, Piero ;
Whitley, Ronald J. ;
Rhead, William J. ;
Hannon, W. Harry ;
Garg, Uttam C. ;
Lo, Stanley F. ;
Bennett, Michael J. .
CLINICAL CHEMISTRY, 2009, 55 (09) :1615-1626
[7]   Expanded newborn screening in New South Wales: missed cases [J].
Estrella, Jane ;
Wilcken, Bridget ;
Carpenter, Kevin ;
Bhattacharya, Kaustuv ;
Tchan, Michel ;
Wiley, Veronica .
JOURNAL OF INHERITED METABOLIC DISEASE, 2014, 37 (06) :881-887
[8]   Stability of Acylcarnitines and Free Carnitine in Dried Blood Samples: Implications for Retrospective Diagnosis of Inborn Errors of Metabolism and Neonatal Screening for Carnitine Transporter Deficiency [J].
Fingerhut, Ralph ;
Ensenauer, Regina ;
Roechinger, Wulf ;
Arnecke, Ralf ;
Olgemoeller, Bernhard ;
Roscher, Adelbert A. .
ANALYTICAL CHEMISTRY, 2009, 81 (09) :3571-3575
[9]  
Fu XW, 2013, JIMD REP, V10, P69, DOI 10.1007/8904_2012_205
[10]   Evaluating Harms in the Assessment of Net Benefit: A Framework for Newborn Screening Condition Review [J].
Goldenberg, Aaron J. ;
Comeau, Anne Marie ;
Grosse, Scott D. ;
Tanksley, Susan ;
Prosser, Lisa A. ;
Ojodu, Jelili ;
Botkin, Jeffrey R. ;
Kemper, Alex R. ;
Green, Nancy S. .
MATERNAL AND CHILD HEALTH JOURNAL, 2016, 20 (03) :693-700