Comparison of 2D and 3D Gamma calculations for an IMRT QA phantom

被引:5
作者
Lafratta, R. [1 ,2 ]
Ibbott, G. [1 ,2 ]
Adamovics, J. [3 ,4 ]
Followill, D. [1 ,2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas Houston, Grad Sch Biomed Sci, Houston, TX 77030 USA
[3] Rider Univ, Lawerenceville, NJ USA
[4] Heuris Pharma LLC, Skillman, NJ 08558 USA
来源
8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE) | 2015年 / 573卷
关键词
RADIATION; DOSIMETRY;
D O I
10.1088/1742-6596/573/1/012055
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Gamma index pass rates were evaluated for an anthropomorphic phantom using both 2D and 3D calculations. The phantom was irradiated with the traditional dosimetry insert loaded with radiochromic film and TLD, and then with a 3D dosimetry insert. A comparison with the calculated dose distribution showed that both the PRESAGE (R) dosimeter and the film and TLD system agreed with the plan to within 5% using 2D gamma index criteria. The 3D gamma index showed a slightly higher pass rate than the 2D gamma index at 3%/3mm, and comparable pass rates using more generous constraints. The acceptable number of pixels passing the tighter constraints (3%/3mm) might be dependent upon the choice between a 2D calculation versus a 3D calculation.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] Evaluation of 3D Printed Anthropomorphic Head Phantom for Calibration of TLD in Eye Lens Dosimeter
    Endarko E.
    Pitaloka A.W.
    Inayah A.A.
    Ramadhan F.R.
    Kardianto K.
    Rahayuningsih B.
    Journal of Biomedical Physics and Engineering, 2023, 13 (02) : 193 - 202
  • [32] Change in Image Quality According to the 3D Locations of a CBCT Phantom
    Hwang, Jae Joon
    Park, Hyok
    Jeong, Ho-Gul
    Han, Sang-Sun
    PLOS ONE, 2016, 11 (04):
  • [33] Investigation of the feasibility of relative 3D dosimetry in the Radiologic Physics Center Head and Neck IMRT phantom using Presage/optical-CT
    Sakhalkar, Harshad
    Sterling, David
    Adamovics, John
    Ibbott, Geoffrey
    Oldham, Mark
    MEDICAL PHYSICS, 2009, 36 (07) : 3371 - 3377
  • [34] A simple backprojection algorithm for 3D in vivo EPID dosimetry of IMRT treatments
    Wendling, Markus
    McDermott, Leah N.
    Mans, Anton
    Sonke, Jan-Jakob
    van Herk, Marcel
    Mijnheer, Ben J.
    MEDICAL PHYSICS, 2009, 36 (07) : 3310 - 3321
  • [35] Iterative approach for 3D reconstruction of the femur from un-calibrated 2D radiographic images
    Youn, Kibeom
    Park, Moon Seok
    Lee, Jehee
    MEDICAL ENGINEERING & PHYSICS, 2017, 50 : 89 - 95
  • [36] Evaluation of 3D printing materials for fabrication of a novel multi-functional 3D thyroid phantom for medical dosimetry and image quality
    Alssabbagh, Moayyad
    Tajuddin, Abd Aziz
    Abdulmanap, Mahayuddin
    Zainon, Rafidah
    RADIATION PHYSICS AND CHEMISTRY, 2017, 135 : 106 - 112
  • [37] Evaluation of 3D printing filaments for construction of a pediatric phantom for dosimetry in CBCT
    Fontes Assemany, Ladyjane Pereira
    Rodrigues Junior, Orlando
    da Silva, Ezequiel
    Potiens, Maria da Penha A.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 167
  • [38] Comparative Analysis of 2D and 3D Metrics for Evaluation of Postoperative Outcomes Following Endoscopic Suturectomy for Sagittal Craniosynostosis
    Medina, Mauricio P.
    Imahiyerobo, Thomas
    Odigie, Eseosa
    Guadix, Sergio W.
    De Silva, Neranjan
    Buontempo, Michelle
    Souweidane, Mark M.
    Hoffman, Caitlin E.
    JOURNAL OF CRANIOFACIAL SURGERY, 2023, 34 (06) : 1699 - 1704
  • [39] Quantitative Evaluation of 2D Versus 3D Dosimetry for Stereotactic Volumetric Modulated Arc Delivery Using COMPASS
    Vikraman, S.
    Manigandan, D.
    Karrthick, K.
    Rajesh, T.
    Sambasivaselli, R.
    Senniandanvar, V.
    Karthikeyan, N.
    Muthukumaran, M.
    Kataria, T.
    MEDICAL PHYSICS, 2014, 41 (06) : 371 - 371
  • [40] 2D and 3D non-destructive evaluation of a wooden panel painting using shearography and terahertz imaging
    Groves, R. M.
    Pradarutti, B.
    Kouloumpi, E.
    Osten, W.
    Notni, G.
    NDT & E INTERNATIONAL, 2009, 42 (06) : 543 - 549