Solid-phase microextraction of phthalate esters in water sample using different activated carbon-polymer monoliths as adsorbents

被引:45
|
作者
Lirio, Stephen [1 ]
Fu, Chung-Wei [1 ]
Lin, Jhih-Yun [1 ]
Hsu, Meng-Ju [1 ]
Huang, Hsi-Ya [1 ]
机构
[1] Chung Yuan Christian Univ, Dept Chem, 200 Chung Pei Rd, Taoyuan 320, Taiwan
关键词
Phthalate ester; Poly(styrene-divinylbenzene); Activated carbon; Polymer monolith; Solid-phase microextraction; CHROMATOGRAPHY MASS-SPECTROMETRY; PI-PI-INTERACTIONS; GAS-CHROMATOGRAPHY; RIVER WATER; FIBER; EXTRACTION; COLUMNS; OXIDE; CONTAMINATION; ENRICHMENT;
D O I
10.1016/j.aca.2016.05.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, the application of different activated carbon-polymer (AC-polymer) monoliths as adsorbents for the solid-phase microextraction (SPME) of phthalate esters (PAEs) in water sample were investigated. The activated carbon (AC) was embedded in organic polymers, poly(butyl methacrylate-co-ethylene dimethacrylate) (poly(BMA-EDMA)) or poly(styrene-co-divinylbenzene) (poly(STY-DVB)), via a 5-min microwave-assisted or a 15-min water bath heating polymerization. Preliminary investigation on the performance of the native poly(BMA-EDMA) and poly(STY-DVB) demonstrated remarkable adsorption efficiencies for PAEs. However, due to the strong hydrophobic, pi-pi, and hydrogen bonding interactions between the analytes and polymers, low extraction recoveries were achieved. In contrast, the presence of AC in native polymers not only enhanced the adsorption efficiencies but also assisted the PAE desorption, especially for AC-poly(STY-DVB) with extraction recovery ranged of 76.2-99.3%. Under the optimized conditions, the extraction recoveries for intra-, inter-day and column-to-column were in the range of 76.5-100.8% (<3.7% RSDs), 77.2-97.6% (<5.6% RSDs) and 75.5-99.7% (<6.2% RSDs), respectively. The developed AC-poly(STY-DVB) monolithic column showed good mechanical stability, which can be reused for more than 30 extraction times without any significant loss in the extraction recoveries of PAEs. The AC-poly(STY-DVB) monolithic column was successfully applied in SPME of PAEs in water sample with extraction recovery ranged of 78.8%-104.6% (<5.5% RSDs). (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:55 / 63
页数:9
相关论文
共 50 条
  • [41] Determination of water pollutants by direct-immersion solid-phase microextraction using polymeric ionic liquid coatings
    Lopez-Darias, Jessica
    Pino, Veronica
    Anderson, Jared L.
    Graham, Christa M.
    Afonso, Ana M.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (08) : 1236 - 1243
  • [42] The benefits of using solid-phase microextraction as a greener sample preparation technique
    Bojko, Barbara
    Pawliszyn, Janusz
    BIOANALYSIS, 2012, 4 (11) : 1263 - 1265
  • [43] Multiwalled Carbon Nanotube Coated on Stainless Steel Wire for Solid-Phase Microextraction of Organochlorine Pesticides in Water
    Feng, Xilan
    Tian, Mengchao
    Li, Aimei
    Zhao, Xuena
    Zhang, Yuping
    ANALYTICAL LETTERS, 2010, 43 (16) : 2477 - 2486
  • [44] Sample Preparation for Gas Chromatography Using Solid-Phase Microextraction with Derivatization
    Snow, Nicholas H.
    ADVANCES IN CHROMATOGRAPHY, VOL 48, 2010, 48 : 373 - +
  • [45] Carbon Dot-Decorated Graphite Carbon Nitride Composites for Enhanced Solid-Phase Microextraction of Chlorobenzenes from Water
    Xu, Shengrui
    Liu, Hailin
    Long, Anying
    Li, Huimin
    Chen, Changpo
    Feng, Suling
    Fan, Jing
    NANOMATERIALS, 2022, 12 (03)
  • [46] Carboxylated solid carbon spheres as a novel solid-phase microextraction coating for sensitive determination of phenols in environmental water samples
    Gong, Sheng-Xiang
    Wang, Xia
    Chen, Yue
    Cheng, Chuan-Ge
    Wang, Ming-Lin
    Zhao, Ru-Song
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1401 : 17 - 23
  • [47] Solid-Phase Microextraction of Phthalate Esters from Aqueous Media by Functionalized Carbon Nanotubes (Graphene Oxide Nanoribbons) and Determination by GC–FID
    Maryam Kazemi
    Ali Niazi
    Atisa Yazdanipour
    Chromatographia, 2021, 84 : 559 - 569
  • [48] Ordered Mesoporous Carbon as Solid-phase Microextraction Coating for Determination of Some Chlorobenzenes in Water
    Jiang Ming-Yue
    Li Jian-Sheng
    Jiang Hui
    Qi Jun-Wen
    Liu Chao
    Wang Lian-Jun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (01) : 1 - 7
  • [49] Effect of the Compositions of Sample and Polymer Sorbents on the Extraction of Volatile Compounds by Solid-Phase Microextraction
    Misharina, T. A.
    Terenina, M. B.
    Krikunova, N. I.
    Mihailov, I. A.
    APPLIED BIOCHEMISTRY AND MICROBIOLOGY, 2018, 54 (01) : 89 - 97
  • [50] Comparison of Solid-Phase Extraction and Solid-Phase Microextraction Using Octadecylsilane Phase for the Determination of Pesticides in Water Samples
    Prieto, Avismelsi
    Araujo, Lilia
    Navalon, Alberto
    Vilchez, Jose L.
    CURRENT ANALYTICAL CHEMISTRY, 2009, 5 (03) : 219 - 224