A Fully Automatic and Highly Efficient Navigator Gating Technique for High-Resolution Free-Breathing Acquisitions: Continuously Adaptive Windowing Strategy

被引:22
作者
Jhooti, P. [1 ,2 ]
Keegan, J. [2 ]
Firmin, D. N. [2 ,3 ]
机构
[1] Univ Basel Hosp, CH-4031 Basel, Switzerland
[2] Univ London Imperial Coll Sci Technol & Med, Royal Brompton Hosp, Cardiovasc Magnet Resonance Unit, London, England
[3] Imperial Coll Sch Med, Natl Heart & Lung Inst, London, England
关键词
artifacts; technique development; technical research; CORONARY MR-ANGIOGRAPHY; MAGNETIC-RESONANCE ANGIOGRAPHY; ARTIFACT REDUCTION; MOTION ARTIFACTS; CONTRAST; MAG;
D O I
10.1002/mrm.22491
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A fully automatic and highly efficient free-breathing navigator gated technique, continuously adaptive windowing strategy (CLAWS), is presented. Using a novel and dynamic acquisition strategy that ensures all potential navigator acceptance windows are possible, CLAWS acquires an image with the highest possible efficiency regardless of variations in the respiratory pattern. Unnecessary prolongation of scan durations due to respiratory drift or navigator acceptance window adjustments are avoided. As CLAWS requires no setting of the acceptance window, nor monitoring of the navigator traces during the scan, operator dependence is minimized and ease of use improved. CLAWS was compared against a standard accept/reject algorithm (ARA) and an end-expiratory following ARA (EE-ARA) in 20 healthy subjects and 10 patients (ARA only). The respiratory efficiency was compared against the retrospectively determined best possible respiratory efficiency for each acquisition. On average, the difference between CLAWS scan times and best possible scan times was 0.6% (+/- 1.3%). For the ARA and EE-ARA techniques, mean differences were 14.4% (+/- 20.9%) and 32.6 +/- 10.9%, respectively. Had the CLAWS algorithm been used with the ARA and EE-ARA traces, mean differences would have been 0.2% (+/- 1.1%) and 0.5% (+/- 1.7%), respectively. Image quality was the same for all techniques: respiratory gating, motion artifacts, navigator, and coronary artery imaging. Magn Reson Med 64:1015-1026, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1015 / 1026
页数:12
相关论文
共 31 条
[1]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[2]   Reduction of transient signal oscillations in True-FISP using a linear flip angle series magnetization preparation [J].
Deshpande, VS ;
Chung, YC ;
Zhang, Q ;
Shea, SM ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) :151-157
[3]  
DESHPANDE VS, 2006, P 14 SCI M INT SOC M, P383
[4]   ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES [J].
EHMAN, RL ;
FELMLEE, JP .
RADIOLOGY, 1989, 173 (01) :255-263
[5]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[6]   3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography [J].
Hackenbroch, M ;
Nehrke, K ;
Gieseke, J ;
Meyer, C ;
Tiemann, K ;
Litt, H ;
Dewald, O ;
Naehle, CP ;
Schild, H ;
Sommer, T .
EUROPEAN RADIOLOGY, 2005, 15 (08) :1598-1606
[7]   Motion artifact reduction and vessel enhancement for free-breathing navigator-gated coronary MRA using 3D k-space reordering [J].
Huber, ME ;
Hengesbach, D ;
Botnar, RM ;
Kissinger, KV ;
Boesiger, P ;
Manning, WJ ;
Stuber, M .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :645-652
[8]  
Jhooti P, 2000, MAGN RESON MED, V43, P470, DOI 10.1002/(SICI)1522-2594(200003)43:3<470::AID-MRM20>3.0.CO
[9]  
2-U
[10]   Hybrid ordered phase encoding (HOPE): An improved approach for respiratory artifact reduction [J].
Jhooti, P ;
Wiesmann, F ;
Taylor, AM ;
Gatehouse, PD ;
Yang, GZ ;
Keegan, J ;
Pennell, DJ ;
Firmin, DN .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04) :968-980