Reliable volumetry of the cervical spinal cord in MS patient follow-up data with cord image analyzer (Cordial)

被引:12
作者
Amann, Michael [1 ,2 ,3 ]
Pezold, Simon [4 ]
Naegelin, Yvonne [2 ]
Fundana, Ketut [4 ]
Andelova, Michaela [2 ]
Weier, Katrin [2 ]
Stippich, Christoph [3 ]
Kappos, Ludwig [2 ]
Radue, Ernst-Wilhelm [1 ]
Cattin, Philippe [4 ]
Sprenger, Till [2 ,5 ]
机构
[1] Med Image Anal Ctr MIAC AG, Mittlere Str 83, CH-4054 Basel, Switzerland
[2] Univ Basel Hosp, Dept Neurol, Petersgraben 4, CH-4031 Basel, Switzerland
[3] Univ Basel Hosp, Dept Radiol, Div Diagnost & Intervent Neuroradiol, Petersgraben 4, CH-4031 Basel, Switzerland
[4] Univ Basel, Dept Biomed Engn, Gewerbestr 14, CH-4123 Allschwil, Switzerland
[5] DKD Helios Klin Wiesbaden, Dept Neurol, Aukammallee 33, D-65191 Wiesbaden, Germany
关键词
Spinal cord; Segmentation; Continuous max flow; Volumetry; Reliability; Multiple sclerosis; Atrophy; Progression; MAGNETIC-RESONANCE IMAGES; MULTIPLE-SCLEROSIS; AUTOMATIC SEGMENTATION; GRAY-MATTER; MRI; ATROPHY; QUANTIFICATION; DISABILITY; ACCURATE; PROGRESSION;
D O I
10.1007/s00415-016-8133-0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Spinal cord (SC) atrophy is an important contributor to the development of disability in many neurological disorders including multiple sclerosis (MS). To assess the spinal cord atrophy in clinical trials and clinical practice, largely automated methods are needed due to the sheer amount of data. Moreover, using these methods in longitudinal trials requires them to deliver highly reliable measurements, enabling comparisons of multiple data sets of the same subject over time. We present a method for SC volumetry using 3D MRI data providing volume measurements for SC sections of fixed length and location. The segmentation combines a continuous max flow approach with SC surface reconstruction that locates the SC boundary based on image voxel intensities. Two cutting planes perpendicular to the SC centerline are determined based on predefined distances to an anatomical landmark, and the cervical SC volume (CSCV) is then calculated in-between these boundaries. The development of the method focused on its application in MRI follow-up studies; the method provides a high scan-rescan reliability, which was tested on healthy subject data. Scan-rescan reliability coefficients of variation (COV) were below 1 %, intra- and interrater COV were even lower (0.1-0.2 %). To show the applicability in longitudinal trials, 3-year follow-up data of 48 patients with a progressive course of MS were assessed. In this cohort, CSCV loss was the only significant predictor of disability progression (p = 0.02). We are, therefore, confident that our method provides a reliable tool for SC volumetry in longitudinal clinical trials.
引用
收藏
页码:1364 / 1374
页数:11
相关论文
共 32 条
  • [1] Association of regional gray matter volume loss and progression of white matter lesions in multiple sclerosis - A longitudinal voxel-based morphometry study
    Bendfeldt, Kerstin
    Kuster, Pascal
    Traud, Stefan
    Egger, Hanspeter
    Winklhofer, Sebastian
    Mueller-Lenke, Nicole
    Naegelin, Yvonne
    Gass, Achim
    Kappos, Ludwig
    Matthews, Paul M.
    Nichols, Thomas E.
    Radue, Ernst-Wilhelm
    Borgwardt, Stefan J.
    [J]. NEUROIMAGE, 2009, 45 (01) : 60 - 67
  • [2] Accurate quantification methods to evaluate cervical cord atrophy in multiple sclerosis patients
    Carbonell-Caballero, J.
    Manjon, J. V.
    Marti-Bonmati, L.
    Olalla, J. R.
    Casanova, B.
    de la Iglesia-Vaya, M.
    Coret, F.
    Robles, M.
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2006, 19 (05) : 237 - 246
  • [3] Automatic magnetic resonance spinal cord segmentation with topology constraints for variable fields of view
    Chen, Min
    Carass, Aaron
    Oh, Jiwon
    Nair, Govind
    Pham, Dzung L.
    Reich, Daniel S.
    Prince, Jerry L.
    [J]. NEUROIMAGE, 2013, 83 : 1051 - 1062
  • [4] Quantification of spinal cord atrophy from magnetic resonance images via a B-spline active surface model
    Coulon, O
    Hickman, SJ
    Parker, GJ
    Barker, GJ
    Miller, DH
    Arridge, SR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) : 1176 - 1185
  • [5] Automatic Segmentation of the Spinal Cord and Spinal Canal Coupled With Vertebral Labeling
    De Leener, Benjamin
    Cohen-Adad, Julien
    Kadoury, Samuel
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (08) : 1705 - 1718
  • [6] Framework for integrated MRI average of the spinal cord white and gray matter: The MNI-Poly-AMU template
    Fonov, V. S.
    Le Troter, A.
    Taso, M.
    De Leener, B.
    Leveque, G.
    Benhamou, M.
    Sdika, M.
    Benali, H.
    Pradat, P. -F.
    Collins, D. L.
    Callot, V.
    Cohen-Adad, J.
    [J]. NEUROIMAGE, 2014, 102 : 817 - 827
  • [7] Frangi AF, 1998, LECT NOTES COMPUT SC, V1496, P130, DOI 10.1007/BFb0056195
  • [8] NMR IMAGING OF THE SPINE
    HAN, JS
    KAUFMAN, B
    ELYOUSEF, SJ
    BENSON, JE
    BONSTELLE, CT
    ALFIDI, RJ
    HAAGA, JR
    YEUNG, H
    HUSS, RG
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 141 (06) : 1137 - 1145
  • [9] A review of biomechanics of the central nervous system - Part II: Spinal cord strains from postural loads
    Harrison, DE
    Cailliet, R
    Harrison, DD
    Troyanovich, SJ
    Harrison, SO
    [J]. JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 1999, 22 (05) : 322 - 332
  • [10] Cervical spinal cord MTR histogram analysis in multiple sclerosis using a 3D acquisition and a B-spline active surface segmentation technique
    Hickman, SJ
    Hadjiprocopis, A
    Coulon, O
    Miller, DH
    Barker, GJ
    [J]. MAGNETIC RESONANCE IMAGING, 2004, 22 (06) : 891 - 895