A Study on Partial Discharge signals and Noises at On-line Generator Stator Windings

被引:0
|
作者
Hee-Sang, Shin [1 ]
Jae-Chul, Kim [1 ]
机构
[1] Soong Sil Univ, Dept Elect Engn, Seoul, South Korea
来源
T& D ASIA: 2009 TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: ASIA AND PACIFIC | 2009年
关键词
diagnosis; high voltage generator; partial-discharge; stator winding;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Recently, the importance of supplying the reliable electric power is increasing. Insulation deterioration of stator winding is a major cause of faults in high voltage generators. Online partial discharge detection is useful technique to diagnose high voltage generators. Capacitive couplers have been the most widely used for on-line partial discharge detection in high voltage generators. However, interpretation of its result in time domain is very complex because of the mixed results with PD(Partial Discharges) and noises. In this paper, the partial discharge signals and noises were detected using 13[kV] class capacitive couplers at generator stator windings of hydro generators. Characteristics of the partial discharge signals and noises were analyzed. In addition, this paper presents system noise signals caused by sparks from slip rings, power tool operations, transformers and switchgears.
引用
收藏
页码:744 / 747
页数:4
相关论文
共 50 条
  • [21] Partial Discharge Detection with High-Frequency Band through Resistance-Temperature Sensor of Hydropower Generator Stator Windings
    Kanegami, Masaki
    Miyazaki, Satoru
    Miyake, Katsuyuki
    ELECTRICAL ENGINEERING IN JAPAN, 2016, 195 (04) : 9 - 15
  • [22] A New Proposed Method for Interpretation On-line Partial Discharge Measurements Data of Turbine Generator
    A. M. Baboraik
    A. E. Usachev
    Ziad M. Ali
    Journal of Electrical Engineering & Technology, 2020, 15 : 1301 - 1311
  • [23] A New Proposed Method for Interpretation On-line Partial Discharge Measurements Data of Turbine Generator
    Baboraik, A. M.
    Usachev, A. E.
    Ali, Ziad M.
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2020, 15 (03) : 1301 - 1311
  • [24] Ubiquitous, On-Line, Partial Discharge Trending
    Andle, Jeffrey C.
    Murray, Jonathan
    Lane, David
    Cunneen, Tom
    2018 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2018, : 186 - 191
  • [25] Summary of industry practices, guides and standards related to on-line partial discharge monitoring of stator insulation condition
    Green, V
    Sasic, M
    Wright, B
    INDUSTRY APPLICATIONS SOCIETY 52ND ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 2005, : 359 - 365
  • [26] Analysis of Transition Cause of Partial Discharge Patterns in High Voltage Motor Stator Windings
    Koo, Ja-Young
    Kwak, Jun-Ho
    Kim, Hee-Dong
    Transactions of the Korean Institute of Electrical Engineers, 2024, 73 (08) : 1456 - 1460
  • [27] Subspace reconstruction to suppress periodic narrowband noises of partial discharge signals
    Duan W.
    Zhang Y.
    Li T.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2017, 37 (07): : 178 - 183
  • [28] On-line monitoring partial discharge in electrical equipments
    Zhu, DH
    Tan, KX
    Wang, CC
    JOINT CONFERENCE OF 96' AICDEI / 4T-JCCEID, 1996, : 329 - 332
  • [29] The Design and Experiment of a Planar Patch Sensor for Partial Discharge Diagnostics in 6.6 kV Rotating Machine Stator Windings
    Yang, Sang-Hyun
    Park, Noh-Joon
    Park, Dae-Hee
    Kim, Hee-Dong
    Lim, Kwang-Jin
    TRANSACTIONS ON ELECTRICAL AND ELECTRONIC MATERIALS, 2009, 10 (05) : 173 - 176
  • [30] On-line Monitoring System for Transformer Partial Discharge
    Liu, Guangya
    Kang, Lu
    Peng, Weina
    SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS, PTS 1-4, 2013, 303-306 : 464 - 467